|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
ADAM-5017UH ADAM-5018 ADAM-5018P 8-ch Ultra High Speed Analog Input Module 7-ch Thermocouple Input Module 7-ch Thermocouple Input Module with Independent Input Range ADAM-5017UH RoHS 2002/95/EC COMPLIANT ADAM-5018 RoHS 2002/95/EC COMPLIANT ADAM-5018P RoHS 2002/95/EC COMPLIANT Specifications General Certifications Connectors Power Consumption CE 1 x Plug-in screw terminal (# 14 ~ 22 AWG) 2.2 W (max.) Specifications General Certifications Connectors CE, FM 1 x Plug-in screw terminal (# 14 ~ 22 AWG) Power Consumption 0.63 W (max.) Specifications General Certifications Connectors CE 1 x Plug-in screw terminal (# 14 ~ 22 AWG) Power Consumption 0.63 W (max.) Analog Input Accuracy 0.1% or better 200 kHz Bandwidth 8 differential Channels Differential Non-linear 1 LSB Voltage: 2 MW Input Impedance Current: 120W (Build-in 12W. register for Current Input) 1 LSB Integral Non-linear mV, V, mA Input Type 10 V, +0 ~ 10 V, Input Range 0 ~ 20 mA, +4 ~ 20 mA Configured by User Low pass filter 12-bit Resolution Depends on base unit Sampling Rate Thermocouple Input Accuracy Bandwidth 0.1% or better 13.1 Hz @ 50 Hz 15.72 Hz @ 60 Hz 7 differential Channels 92 dB min CMR @ 50/60 Hz 2 MW Input Impedance 15 mV, 50 mV, 100 mV, lnput Range 500 mV, 1 V, 2.5 V, 20 mA mV, V, mA,thermocouple lnput Type 16-bit Resolution 10 samples/sec. (total) Sampling Rate 25 PPM/ C Span Drift Zero Drift 6 V/ C T/C Type and Temperature Range J 0 ~ 760 C K 0 ~ 1,370 C T -100 ~ 400 C E 0 ~ 1,000 C R 500 ~ 1,750 C S 500 ~ 1,750 C B 500 ~ 1,800 C Thermocouple Input Accuracy Bandwidth 0.1% or better 13.1 Hz @ 50 Hz 15.72 Hz @ 60 Hz Channels 7 differential with Independent Input Range CMR @ 50/60 Hz 92 dB min Input Impedance 20 MW. (Build-in 120 W Register for Current Input) lnput Range and Types Thermocouple J 0 ~ 760 C K 0 ~ 1,370 C T -100 ~ 400 C E 0 ~ 1,000 C R 500 ~ 1,750 C S 500 ~ 1,750 C B 500 ~ 1,800 C Current mode 20 mA, 4 ~ 20 mA Voltage 15 mV (0.2%), 50 mV, 100 mV, 500 mV 1 V, 2.5 V Resolution 16-bit Sampling Rate 10 samples/sec. (total) Span Drift 25 PPM/C Zero Drift 6 V/C High Common Mode 200 VDC ADAM-5000/485 & 5000E: 100 Samples/sec max (Total): one ADAM-5017UH installed ADAM-5000/TCP: 100 Samples/sec max (Total) :one ADAM-5017UH installed ADAM-5510 : 200K Samples/sec max (Single Channel): one ADAM-5017UH installed ADAM-5550 : 1K Samples/sec per channel: one ADAM-5017UH installed *Depending on the performance of client server or controller Signal Input 200 kHz for both voltage and current inputs Bandwidth Protection Fault and Overvoltage Protection Isolation Voltage Withstands overvoltage up to 35 V 3,000 VDC Protection Fault and Withstands overvoltage up Overvoltage to 35 V Protection Isolation Voltage 3,000 VDC Filter function Yes Built-in TVS/ESD Protection Note: Not support ADAM-5510KW series Protection Isolation Voltage 3,000 VDC Note: 1) The voltage difference between any two pins must not exceed 15 V 2) Distinct range settings allowed on each channel Note: Not support ADAM-5510KW series Ordering Information ADAM-5018 7-ch Thermocouple Input Module Ordering Information ADAM-5017UH 8-ch Ultra High Speed Analog Input Module Ordering Information ADAM-5018P 7-ch Thermo. Input Module w/ Ind. Input Range PC-based Controllers & I/O Modules |
Price & Availability of ADAM-5017UH |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |