|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
WRA240 SERIES 3PH AC - DC DIN RAIL MOUNTABLE 240W INDUSTRIAL CONTROL EQUIPMENT FEATURES 3 PHASE AC INPUT VOLTAGE COMPACT DESIGN HIGH EFFICIENCY UP TO 91% PARALLEL FUNCTION AVAILABLE (SWITCH) SELECTION CHART WRA 240 - 24 Wattage 24 : 24V OUT 48 : 48V OUT MODEL LIST MODEL NO. INPUT VOLTAGE 3o 340~575VAC 3o 340~575VAC OUTPUT OUTPUT WATTAGE VOLTAGE Single Output Models 240 WATTS 240 WATTS + 24 VDC + 48 VDC OUTPUT CURRENT 10A 5A EFF. (min.) 88% 89% EFF. (typ.) 90% 91% WRA240-24 WRA240-48 SPECIFICATION All Specifications Typical At Nominal Line, Full Load, 25oC Unless Otherwise Noticed GENERAL Characteristics Isolation voltage Isolation resistance Ambient temperature Derating Storage temperature Relative humidity Dimension Cooling Case material Conditions Conditions Input / Output Input / Output, @ 500VDC Operating at Vi nom Vi nom, from +61 to +71 C Non operational Vi nom, Io nom Screw terminal type Free air convection Metal o min. min. 3,000 100 -25 -25 20 typ. typ. max. max. unit unit VAC M + 71 2.5 + 85 95 o o C C %/ C o % RH mm L123.6 x W89.0 x D118.2 www.chinfa.com 2008.08.14 sales@chinfa.com WRA240 SERIES SPECIFICATION All Specifications Typical At Nominal Line, Full Load, 25oC Unless Otherwise Noticed INPUT SPECIFICATIONS Characteristics Nominal Voltage *1 Rated input voltage Input voltage range Rated input current Line frequency Inrush current P F. C. . Io nom Ta min ... T max, a Io nom Io nom Vi nom, Io nom Vi nom, Io nom Vi : 500VAC, Io nom AC IN DC IN Vi : 380VAC Vi : 500VAC 47 20 0.6 400 340 480 0.85 0.7 63 Conditions min. typ. max. 500 575 820 unit VAC VAC VDC A A Hz A 1o or 3o 380 / 480 VAC OUTPUT SPECIFICATIONS Characteristics Output voltage accuracy (Adjusted before shipment) Conditions Vi nom, Io max Vi nom Io nom, Vi min ...Vi max Vi nom, Io min ...Io nom Vi nom, Io min Vi nom, Io nom,BW = 20MHz Vi nom, Io nom Vi nom, Io nom 24V model 48V model 24V model 48V model Vi nom, Io nom 0.9 Io max Vi nom, Io nom, Po / Pi 24V model 48V model single mode parallel mode min. -0 0 typ. max. +1 1 1 5 0.02 100 unit % % % % % % / oC mV ms VDC VDC VDC VDC VDC VDC unit Minimum load Line regulation Load regulation Temperature coefficient Ripple & noise Hold up time Voltage trim range 16 20 22.5 47 17.6 37 17.6 37 Up to 91% 28.5 56 19.4 43 19.4 43 2 DC ON indicator threshold at start up DC LOW indicator threshold at start up Parallel operation Efficiency Vi nom, Io nom CONTROL AND PROTECTION Characteristics Input fuse Rated over load protection Power Rdy (for 24V model only) Vi nom Threshold voltage of contact closed(at start up) Electrical isolation Contact rating at 60VDC Conditions min. 120 17.6 500 typ. max. 140 19.4 0.3 unit % VDC VDC A V V 2A / 600VAC internal / phase Over voltage protection Output short circuit Over temperature Vi nom, Io nom Vi nom 24V model 48V model 30 60 33 68 Current limited 100 110 o Detect on heatsink, shut down O/P voltage, recovers automatically after temperature goes down. C *1. Single phase input is permissible, but output is derated to 75%. www.chinfa.com 2008.08.14 sales@chinfa.com WRA240 SERIES SPECIFICATION All Specifications Typical At Nominal Line, Full Load, 25oC Unless Otherwise Noticed APPROVALS AND STANDARDS UL / cUL TUV CE UL508 Listed, UL60950-1 Recognized EN60950-1 EN61000-6-3, EN55022 class B EN61000-3-2, EN61000-3-3 EN61000-6-2, EN55024 EN61204-3 CIRCUIT SCHEMATIC Block diagram for WRA240 series L1 L2 L3 Fuse1 Fuse2 Fuse3 Filter X X X Vo + Bridge Rectifier Filter P .F.C Circuit Switching Device Rectifier Current Detection Vo Single / Parallel Select Vout ADJ. Y PWM Controller Opto Isolation Opto Isolation Reference & Error Amp. Over Voltage Detection Output Level Detection Note: 1) For 24V Model Only DC ON (Green LED) DC LOW (Red LED) RDY 1) (Relay Contact) PHYSICAL CHARACTERISTICS CASE SIZE SCREW TERMINAL TYPE 123.6 x 89.0 x 118.2 mm (4.87 x 3.5 x 4.65 inches) 1100g WEIGHT DERATING 100 Power out [ % ] 75 0 -25 Temperature [ oC ] 61 71 www.chinfa.com 2008.08.14 sales@chinfa.com WRA240 SERIES MECHANISM & PIN CONFIGURATION mm [inch] 111.3 [4.38] 106.6 [4.2] 6.9 [0.27] WRA240 123.60 [4.87] Rdy IND.CONT.EQ. E196362 2JF4 CHINFA Chinfa Electronics ind. Co., Ltd. ISO 9001 Certified DC LO DC ON L1 L2 L3 ++ 5 8 89 [3.5] 1 4 CONSTRUCTION Easy snap-on mounting onto the DIN-Rail (TS35/7.5 or TS35/15), unit sits safeIy and firmly on the rail. 9 10 INSTALLATION Ventilation / Cooling Normal convection All sides 25mm free space For cooling recommended Connector size range 10-24AWG flexible / solid cable, 8 m/m stripping at cable end recommends PIN ASSIGNMENT PIN NO. 1 Designation V+ Description Positive output terminal Positive output terminal Negative output terminal Negative output terminal Ground this terminal to minimize high-frequency emissions Input terminals Input terminals Input terminals A normal open relay contact for DC ON level control (Never connect except 24V model) Operation indicator LED DC LOW voltage indicator LED Trimmer-potentiometer for Vout adjustment Single / Parallel select switch 3 4 5 7 8 10 9 6 OUT 2 V+ VVL1 L2 L3 RDY RDY DC ON DC LO Vout ADJ. S/P www.chinfa.com 2008.08.14 OTHER OUT IN sales@chinfa.com |
Price & Availability of WRA240-24 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |