![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
EtronTech Etron Confidential Features * * * * * * * * Fast clock rate: 200MHz Differential Clock CK & CK Bi-directional DQS DLL enable/disable by EMRS Fully synchronous operation Internal pipeline architecture Four internal banks, 8M x 16-bit for each bank Programmable Mode and Extended Mode registers - CAS Latency: 2, 2.5, 3 - Burst length: 2, 4, 8 - Burst Type: Sequential & Interleaved Individual byte write mask control * * DM Write Latency = 0 * Auto Refresh and Self Refresh * 8192 refresh cycles / 64ms * Precharge & active power down * Power supplies: VDD & VDDQ = 2.5V 5% * Interface: SSTL_2 I/O Interface * Package: 66 Pin TSOP II, 0.65mm pin pitch - Pb and Halogen free EM6AB160TSA Advanced (Rev. 1.3 May / 2009) Table 1.Ordering Information Clock Data Rate Package Frequency EM6AB160TSA-5G 200MHz 400Mbps/pin TSOPII Part Number TS : indicates TSOPII package A: indicates Generation Code G: indicates Pb and Halogen free 32M x 16 bit DDR Synchronous DRAM (SDRAM) Figure 1. Pin Assignment (Top View) VDD DQ0 VDDQ DQ1 DQ2 VSSQ DQ3 DQ4 VDDQ DQ5 DQ6 VSSQ DQ7 NC VDDQ LDQS NC VDD NC LDM WE CAS RAS CS NC BA0 BA1 A10/AP A0 A1 A2 A3 VDD 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 VSS DQ15 VSSQ DQ14 DQ13 VDDQ DQ12 DQ11 VSSQ DQ10 DQ9 VDDQ DQ8 NC VSSQ UDQS NC VREF VSS UDM CK CK CKE NC A12 A11 A9 A8 A7 A6 A5 A4 VSS Overview The EM6AB160 SDRAM is a high-speed CMOS double data rate synchronous DRAM containing 512 Mbits. It is internally configured as a quad 8M x 16 DRAM with a synchronous interface (all signals are registered on the positive edge of the clock signal, CK). Data outputs occur at both rising edges of CK and CK .d Read and write accesses to the SDRAM are burst oriented; accesses start at a selected location and continue for a programmed number of locations in a programmed sequence. Accesses begin with the registration of a BankActivate command which is then followed by a Read or Write command. The EM6AB160 provides programmable Read or Write burst lengths of 2, 4, or 8. An auto precharge function may be enabled to provide a selftimed row precharge that is initiated at the end of the burst sequence. The refresh functions, either Auto or Self Refresh are easy to use. In addition, EM6AB160 features programmable DLL option. By having a programmable mode register and extended mode register, the system can choose the most suitable modes to maximize its performance. These devices are well suited for applications requiring high memory bandwidth, result in a device particularly well suited to high performance main memory and graphics applications. Etron Technology, Inc. No. 6, Technology Rd. V, Hsinchu Science Park, Hsinchu, Taiwan 30078, R.O.C. TEL: (886)-3-5782345 FAX: (886)-3-5778671 Etron Technology, Inc. reserves the right to change products or specification without notice. EtronTech Figure 2. Block Diagram EM6AB160TSA CK CK CKE DLL CLOCK BUFFER Row Decoder Row Decoder Row Decoder Row Decoder CS RAS CAS WE COMMAND DECODER CONTROL SIGNAL GENERATOR 8M x 16 CELL ARRAY (BANK #0) Column Decoder A10/AP COLUMN COUNTER MODE REGISTER 8M x 16 CELL ARRAY (BANK #1) Column Decoder A0 A9 A11 A12 BA0 BA1 LDQS UDQS DQ0 DQ15 ~ ~ ADDRESS BUFFER REFRESH COUNTER 8M x 16 CELL ARRAY (BANK #2) Column Decoder DATA STROBE BUFFER DQ Buffer 8M x 16 CELL ARRAY (BANK #3) Column Decoder LDM UDM Etron Confidential 2 Rev.1.3 May 2009 EtronTech Pin Descriptions Table 2. Pin Details of EM6AB160 Symbol CK, CK Type Input Description EM6AB160TSA Differential Clock: CK and CK are differential clock inputs. All address and control input signals are sampled on the crossing of the positive edge of CK and negative edge of CK . Input and output data is referenced to the crossing of CK and CK (both directions of the crossing) Clock Enable: CKE activates (HIGH) and deactivates (LOW) the CK signal. If CKE goes low synchronously with clock, the internal clock is suspended from the next clock cycle and the state of output and burst address is frozen as long as the CKE remains low. When all banks are in the idle state, deactivating the clock controls the entry to the Power Down and Self Refresh modes. Bank Activate: BA0 and BA1 define to which bank the BankActivate, Read, Write, or BankPrecharge command is being applied. Address Inputs: A0-A12 are sampled during the BankActivate command (row address A0-A12) and Read/Write command (column address A0-A9 with A10 defining Auto Precharge). Chip Select: CS enables (sampled LOW) and disables (sampled HIGH) the command decoder. All commands are masked when CS is sampled HIGH. CS provides for external bank selection on systems with multiple banks. It is considered part of the command code. Row Address Strobe: The RAS signal defines the operation commands in conjunction with the CAS and WE signals and is latched at the positive edges of CK. When RAS and CS are asserted "LOW" and CAS is asserted "HIGH," either the BankActivate command or the Precharge command is selected by the WE signal. When the WE is asserted "HIGH," the BankActivate command is selected and the bank designated by BA is turned on to the active state. When the WE is asserted "LOW," the Precharge command is selected and the bank designated by BA is switched to the idle state after the precharge operation. Column Address Strobe: The CAS signal defines the operation commands in conjunction with the RAS and WE signals and is latched at the positive edges of CK. When RAS is held "HIGH" and CS is asserted "LOW," the column access is started by asserting CAS "LOW." Then, the Read or Write command is selected by asserting WE "HIGH" or "LOW". Write Enable: The WE signal defines the operation commands in conjunction with the RAS and CAS signals and is latched at the positive edges of CK. The WE input is used to select the BankActivate or Precharge command and Read or Write command. Bidirectional Data Strobe: Specifies timing for Input and Output data. Read Data Strobe is edge triggered. Write Data Strobe provides a setup and hold time for data and DQM. LDQS is for DQ0~7, UDQS is for DQ8~15. Data Input Mask: Input data is masked when DM is sampled HIGH during a write cycle. LDM masks DQ0-DQ7, UDM masks DQ8-DQ15. Data I/O: The DQ0-DQ15 input and output data are synchronized with the positive edges of CK and CK . The I/Os are byte-maskable during Writes. Power Supply: 2.5V CKE Input BA0, BA1 A0-A12 Input Input CS Input RAS Input CAS Input WE Input LDQS, UDQS LDM, UDM DQ0 - DQ15 VDD Input / Output Input Input / Output Supply 5% . Etron Confidential 3 Rev.1.3 May 2009 EtronTech VSS VDDQ VSSQ VREF NC Supply Supply Supply Supply Ground DQ Power: 2.5V EM6AB160TSA 5% . Provide isolated power to DQs for improved noise immunity. DQ Ground: Provide isolated ground to DQs for improved noise immunity. Reference Voltage for Inputs: +0.5*VDDQ No Connect: These pins should be left unconnected. Etron Confidential 4 Rev.1.3 May 2009 EtronTech Operation Mode Table 3 shows the truth table for the operation commands. EM6AB160TSA Table 3. Truth Table (Note (1), (2)) Command BankActivate BankPrecharge PrechargeAll Write Write and AutoPrecharge Read Read and Autoprecharge Mode Register Set Extended MRS No-Operation Burst Stop Device Deselect AutoRefresh SelfRefresh Entry SelfRefresh Exit State CKEn-1 CKEn UDM LDM BA0,1 A10 A0-9, 11-12 CS RAS CAS WE Idle(3) Any Any Active(3) Active(3) Active(3) Active(3) Idle Idle Any Active(4) Any Idle Idle Idle (SelfRefresh) H H H H H H H H H H H H H H L H L H L H X X X X X X X X X X X X H L H L H L H X X X X X X X X X X X X X X X X X X X X L X X X X X X X X X X X X X X X X X X X L V V X V V V V Row address L H L H L H X X Column address (A0 ~ A9) Column address (A0 ~ A9) L L L L L L L L L L L L H H H H L L H H X L L X H X H X H X V X H X X H H H L L L L L L H H X L L X H X H X H X V X H X X H L L L L H H L L H L X H H X H X H X H X V X H X X OP code OP code X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X L L H L L H L H L H L H L H L X Precharge Power Down Mode Entry Precharge Power Down Mode Exit Active Power Down Mode Entry Active Power Down Mode Exit Data Input Mask Disable Data Input Mask Enable(5) Idle Any (PowerDown) Active Any (PowerDown) Active Active H X H H X X X X Note: 1. V=Valid data, X=Don't Care, L=Low level, H=High level 2. CKEn signal is input level when commands are provided. CKEn-1 signal is input level one clock cycle before the commands are provided. 3. These are states of bank designated by BA signal. 4. Device state is 2, 4, and 8 burst operation. 5. LDM and UDM can be enabled respectively. Etron Confidential 5 Rev.1.3 May 2009 EtronTech Mode Register Set (MRS) EM6AB160TSA The Mode Register stores the data for controlling various operating modes of a DDR SDRAM. It programs CAS Latency, Burst Type, and Burst Length to make the DDR SDRAM useful for a variety of applications. The default value of the Mode Register is not defined; therefore the Mode Register must be written by the user. Values stored in the register will be retained until the register is reprogrammed. The Mode Register is written by asserting Low on CS , RAS , CAS , WE , BA1 and BA0 (the device should have all banks idle with no bursts in progress prior to writing into the mode register, and CKE should be High). The state of address pins A0~A12 and BA0, BA1 in the same cycle in which CS , RAS , CAS and WE are asserted Low is written into the Mode Register. A minimum of two clock cycles, tMRD, are required to complete the write operation in the Mode Register. The Mode Register is divided into various fields depending on functionality. The Burst Length uses A0~A2, Burst Type uses A3, and CAS Latency (read latency from column address) uses A4~A6. A logic 0 should be programmed to all the undefined addresses to ensure future compatibility. Reserved states should not be used to avoid unknown device operation or incompatibility with future versions. Refer to the table for specific codes for various burst lengths, burst types and CAS latencies. Table 4. Mode Register Bitmap BA1 BA0 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0 Address Field 0 0 RFU must be set to "0" T.M. CAS Latency BT Burst Length Mode Register A8 0 1 X A7 Test Mode 0 Normal mode 0 DLL Reset 1 Test mode BA0 Mode 0 MRS 1 EMRS A6 0 0 0 0 1 1 1 1 A5 0 0 1 1 0 0 1 1 A4 CAS Latency 0 Reserved 1 Reserved 0 2 1 3 0 Reserved 1 Reserved 0 2.5 1 Reserved A3 Burst Type 0 Sequential 1 Interleave A2 0 0 0 0 1 1 1 1 A1 0 0 1 1 0 0 1 1 A0 Burst Length 0 Reserved 1 2 0 4 1 8 0 Reserved 1 Reserved 0 Reserved 1 Reserved * Burst Length Field (A2~A0) This field specifies the data length of column access using the A2~A0 pins and selects the Burst Length to be 2, 4, 8. Table 5. Burst Length A2 0 0 0 0 1 1 1 1 A1 0 0 1 1 0 0 1 1 A0 0 1 0 1 0 1 0 1 Burst Length Reserved 2 4 8 Reserved Reserved Reserved Reserved Etron Confidential 6 Rev.1.3 May 2009 EtronTech Table 6. Addressing Mode A3 0 1 * EM6AB160TSA * Addressing Mode Select Field (A3) The Addressing Mode can be one of two modes, either Interleave Mode or Sequential Mode. Both Sequential Mode and Interleave Mode support burst length of 2, 4 and 8. Addressing Mode Sequential Interleave Burst Definition, Addressing Sequence of Sequential and Interleave Mode Table 7. Burst Address ordering Burst Length 2 A2 X X X X X X 0 0 0 0 1 1 1 1 Start Address A1 A0 X 0 X 1 0 0 0 1 1 0 1 1 0 0 0 1 1 0 1 1 0 0 0 1 1 0 1 1 Sequential 0, 1 1, 0 0, 1, 2, 3 1, 2, 3, 0 2, 3, 0, 1 3, 0, 1, 2 0, 1, 2, 3, 4, 5, 6, 7 1, 2, 3, 4, 5, 6, 7, 0 2, 3, 4, 5, 6, 7, 0, 1 3, 4, 5, 6, 7, 0, 1, 2 4, 5, 6, 7, 0, 1, 2, 3 5, 6, 7, 0, 1, 2, 3, 4 6, 7, 0, 1, 2, 3, 4, 5 7, 0, 1, 2, 3, 4, 5, 6 Interleave 0, 1 1, 0 0, 1, 2, 3 1, 0, 3, 2 2, 3, 0, 1 3, 2, 1, 0 0, 1, 2, 3, 4, 5, 6, 7 1, 0, 3, 2, 5, 4, 7, 6 2, 3, 0, 1, 6, 7, 4, 5 3, 2, 1, 0, 7, 6, 5, 4 4, 5, 6, 7, 0, 1, 2, 3 5, 4, 7, 6, 1, 0, 3, 2 6, 7, 4, 5, 2, 3, 0, 1 7, 6, 5, 4, 3, 2, 1, 0 4 8 * CAS Latency Field (A6~A4) This field specifies the number of clock cycles from the assertion of the Read command to the first read data. The minimum whole value of CAS Latency depends on the frequency of CK. The minimum whole value satisfying the following formula must be programmed into this field. tCAC(min) CAS Latency X tCK Table 8. CAS Latency A6 0 0 0 0 1 1 1 1 A5 0 0 1 1 0 0 1 1 A4 0 1 0 1 0 1 0 1 CAS Latency Reserved Reserved 2 clocks 3 clocks Reserved Reserved 2.5 clocks Reserved * Test Mode field (A8~A7) These two bits are used to enter the test mode and must be programmed to "00" in normal operation. Table 9. Test Mode A8 0 1 A7 0 0 Test Mode Normal mode DLL Reset Etron Confidential 7 Rev.1.3 May 2009 EtronTech * ( BA0, BA1) EM6AB160TSA Table 10. MRS/EMRS BA1 RFU RFU BA0 0 1 A12 ~ A0 MRS Cycle Extended Functions (EMRS) Etron Confidential 8 Rev.1.3 May 2009 EtronTech Extended Mode Register Set (EMRS) EM6AB160TSA The Extended Mode Register Set stores the data for enabling or disabling DLL and selecting output driver strength. The default value of the extended mode register is not defined, therefore must be written after power up for proper operation. The Extened Mode Register is written by asserting Low on CS , RAS , CAS , WE , BA1 and BA0 (the device should have all banks idle with no bursts in progress prior to writing into the mode register, and CKE should be High). The state of A0 ~ A12, BA0 and BA1 is written in the mode register in the same cycle as CS , RAS , CAS , and WE going low. The DDR SDRAM should be in all bank precharge with CKE already high prior to writing into the extended mode register. A1 is used for setting driver strength to normal, or weak. Two clock cycles are required to complete the write operation in the extended mode register. The mode register contents can be changed using the same command and clock cycle requirements during operation as long as all banks are in the idle state. A0 is used for DLL enable or disable. "High" on BA0 is used for EMRS. Refer to the table for specific codes. Table 11. Extended Mode Register Bitmap BA1 BA0 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0 Address Field 0 1 RFU must be set to "0" DS0 DLL Extend Mode Register BA0 0 1 Mode MRS EMRS A1 0 1 Drive Strength Full Weak A0 0 1 DLL Enable Disable Etron Confidential 9 Rev.1.3 May 2009 EtronTech Table 12.Absolute Maximum Rating Symbol Item Rating EM6AB160TSA Unit VIN, VOUT VDD, VDDQ TA TSTG TSOLDER PD Input, Output Voltage Power Supply Voltage Ambient Temperature Storage Temperature Soldering Temperature Power Dissipation - 0.5~ VDDQ + 0.5 - 1~3.6 0~70 - 55~150 260 1.5 V V C C C W IOUT Short Circuit Output Current 50 mA Note1: Stress greater than those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. Note2: These voltages are relative to Vss Table 13. Recommended D.C. Operating Conditions (TA = 0 ~ 70 C) Parameter Symbol Min. Max. Unit Note Power Supply Voltage Power Supply Voltage (for I/O Buffer) Input Reference Voltage Input High Voltage (DC) Input Low Voltage (DC) Termination Voltage Input Voltage Level, CLK and CLK inputs Input Different Voltage, CLK and CLK inputs Input leakage current Output leakage current Output High Voltage Output Low Voltage Note : All voltages are referenced to VSS. VDD VDDQ VREF 2.375 2.375 0.49*VDDQ 2.625 2.625 0.51* VDDQ VDDQ + 0.3 VREF - 0.15 VREF + 0.04 VDDQ + 0.3 VDDQ + 0.6 2 5 VTT - 0.76 V V V V V V V V A A VIH (DC) VREF + 0.15 VIL (DC) VTT VIN (DC) VID (DC) II IOZ VOH VOL -0.3 VREF - 0.04 -0.3 0.36 -2 -5 VTT + 0.76 - V V IOH = -15.2 mA IOL = +15.2 mA Table 14. Capacitance (VDD = 2.5V, f = 1MHz, TA = 25 C) Symbol Parameter Min. Max. Unit CIN1 CIN2 Input Capacitance (CK, CK ) Input Capacitance (All other input-only pins) 2.5 2.5 3.5 3.5 pF pF CI/O DQ, DQS, DM Input/Output Capacitance 4.0 5.0 pF Note: These parameters are guaranteed by design, periodically sampled and are not 100% tested Etron Confidential 10 Rev.1.3 May 2009 EtronTech Table 15. D.C. Characteristics (VDD = 2.5V 5%, TA = 0~70 C) Parameter & Test Condition OPERATING CURRENT: One bank; Active-Precharge; tRC=tRC(min); tCK=tCK(min); DQ,DM and DQS inputs changing once per clock cycle; Address and control inputs changing once every two clock cycles. OPERATING CURRENT : One bank; Active-ReadPrecharge; BL=4; tRC=tRC(min); tCK=tCK(min); lout=0mA; Address and control inputs changing once per clock cycle PRECHARGE POWER-DOWN STANDBY CURRENT: All banks idle; power-down mode; tCK=tCK(min); CKE=LOW IDLE STANDLY CURRENT : CKE = HIGH; CS =HIGH(DESELECT); All banks idle; tCK=tCK(min); Address and control inputs changing once per clock cycle; VIN=VREF for DQ, DQS and DM ACTIVE POWER-DOWN STANDBY CURRENT : one bank active; power-down mode; CKE=LOW; tCK=tCK(min) ACTIVE STANDBY CURRENT : CS =HIGH;CKE=HIGH; one bank active ; tRC=tRC(max);tCK=tCK(min);Address and control inputs changing once per clock cycle; DQ,DQS,and DM inputs changing twice per clock cycle OPERATING CURRENT BURST READ : BL=2; READS; Continuous burst; one bank active; Address and control inputs changing once per clock cycle; tCK=tCK(min); lout=0mA;50% of data changing on every transfer OPERATING CURRENT BURST Write : BL=2; WRITES; Continuous Burst ;one bank active; address and control inputs changing once per clock cycle; tCK=tCK(min); DQ,DQS,and DM changing twice per clock cycle; 50% of data changing on every transfer AUTO REFRESH CURRENT : tRC=tRFC(min); tCK=tCK(min) SELF REFRESH CURRENT: Sell Refresh Mode ; CKE 0.2V;tCK=tCK(min) Symbol EM6AB160TSA -5 Max. Unit Notes IDD0 220 mA IDD1 IDD2P 250 40 mA mA IDD2N 70 mA IDD3P 55 mA IDD3N 100 mA IDD4R 420 mA IDD4W 420 mA IDD5 IDD6 290 6 mA mA 1 Etron Confidential 11 Rev.1.3 May 2009 EtronTech (VDD = 2.5V 5%, TA = 0~70 C) Symbol Parameter -5 EM6AB160TSA Table 16.Electrical Characteristics and Recommended A.C.Operating Condition tCK tCH tCL tHP tHZ tLZ tDQSCK tAC tDQSQ tRPRE tRPST tDQSS tWPRES tWPRE tWPST tDQSH tDQSL tIS tIH tDS tDH tQH tRC tRFC tRAS tRCD tRP tRRD tWR tWTR tMRD tREFI tXSRD tXSNR tDAL tDIPW tIPW Clock cycle time Clock high level width Clock low level width Clock half period CL = 2 CL = 2.5 CL = 3 Min. 7.5 6 5 0.45 0.45 tCLMIN or tCHMIN Max. 10 10 10 0.55 0.55 - Unit Note ns ns ns tCK tCK ns ns ns ns ns ns tCK tCK tCK ns tCK tCK tCK tCK ns ns ns ns ns ns ns ns ns ns ns ns tCK ns s tCK ns ns ns ns 2 3 3 Data-out-high impedance time from CK, CK Data-out-low impedance time from CK, CK DQS-out access time from CK, CK Output access time from CK, CK DQS-DQ Skew Read preamble Read postamble CK to valid DQS-in DQS-in setup time DQS Write preamble DQS write postamble DQS in high level pulse width DQS in low level pulse width Address and Control input setup time Address and Control input hold time DQ & DM setup time to DQS DQ & DM hold time to DQS DQ/DQS output hold time from DQS Row cycle time Refresh row cycle time Row active time RAS to CAS Delay Row precharge time Row active to Row active delay Write recovery time Internal Write to Read Command Delay Mode register set cycle time Average Periodic Refresh interval Self refresh exit to read command delay Self refresh exit to non-read command delay Auto Precharge write recovery + precharge time DQ and DM input puls width Cntrol and Address input pulse width -0.7 -0.7 -0.7 0.9 0.4 0.8 0 0.35 0.4 0.35 0.35 0.9 0.9 0.45 0.45 tHP -0.55 60 72 40 20 20 10 15 2 10 200 75 35 1.75 2.2 0.7 0.7 0.7 0.7 0.45 1.1 0.6 1.2 0.6 120K 7.8 - 4 5 6 6 7 Etron Confidential 12 Rev.1.3 May 2009 EtronTech Parameter Symbol Min. EM6AB160TSA Max. Unit Table 17. Recommended A.C. Operating Conditions (VDD = 2.5V 5%, TA = 0~70 C) Input High Voltage (AC) Input Low Voltage (AC) Input Different Voltage, CK and CK inputs VIH (AC) VIL (AC) VID (AC) VREF + 0.35 0.7 0.5*VDDQ-0.2 VREF - 0.35 VDDQ + 0.6 0.5*VDDQ+0.2 V V V V Input Crossing Point Voltage, CK and CK inputs VIX (AC) Note: 1) Enables on-chip refresh and address counters. 2) Min(tCL, tCH) refers to ther smaller of the actual clock low time and actual clock high time as provided to the device. 3) tHZ and tLZ transitions occur in the same access time windows as valid data transitions. These parameters are not referenced to a specific voltage level, but specify when the device output is no longer driving(HZ), or begins driving(LZ). 4) The specific requirement is that DQS be valid (High, Low, or at some point on a valid transition) on or before this CLK edge. A valid transition is defined as monotonic, and meeting the input slew rate specifications of the device. When no writes were previously in progress on the bus, DQS will be transitioning from High-Z to logic LOW. If a previous write was in progress, DQS could be HIGH, LOW, or transitioning from HIGH to LOW at this time, depending on tDQSS. 5) The maximum limit for this parameter is not a device limit. The device will operate with a greater value for this parameter, but system performance (bus turnaround) will degrade accordingly. 6) For command/address and CK & CK slew rate 1.0V/ns. 7) A maximum of eight AUTO REFRESH commands can be posted to any given DDR SDRAM device. 8) Power-up sequence is described in Note 10 9) A.C. Test Conditions Etron Confidential 13 Rev.1.3 May 2009 EtronTech Table 17. SSTL _2 Interface Reference Level of Output Signals (VREF) Output Load Input Signal Levels Input Signals Slew Rate Reference Level of Input Signals 0.5 * VDDQ EM6AB160TSA Reference to the Test Load VREF+0.35 V / VREF-0.35 V 1 V/ns 0.5 * VDDQ Figure 3. SSTL_2 A.C. Test Load 0.5 * VDDQ 50 DQ, DQS Z0=50 30pF 10) Power up Sequence Power up must be performed in the following sequence. 1) Apply power to VDD before or at the same time as VDDQ, VTT and VREF when all input signals are held "NOP" state and maintain CKE "LOW". 2) Start clock and maintain stable condition for minimum 200s. 3) Issue a "NOP" command and keep CKE "HIGH" 4) Issue a "Precharge All" command. 5) Issue EMRS - enable DLL. 6) Issue MRS - reset DLL. (An additional 200 clock cycles are required to lock the DLL). 7) Precharge all banks of the device. 8) Issue two or more Auto Refresh commands. 9) Issue MRS - with A8 to low to initialize the mode register. Etron Confidential 14 Rev.1.3 May 2009 EtronTech Timing Waveforms Figure 4. Activating a Specific Row in a Specific Bank CK CK CKE CS HIGH EM6AB160TSA RAS CAS WE Address RA BA0,1 BA RA=Row Address BA=Bank Address Don't Care Etron Confidential 15 Rev.1.3 May 2009 EtronTech Figure 5. tRCD and tRRD Definition CK CK EM6AB160TSA COMMAND ACT NOP NOP ACT NOP NOP RD/WR NOP Address Row Row Col BA0,BA1 Bank A Bank B Bank B tRRD tRCD Don't Care Figure 6. READ Command CK CK CKE CS RAS CAS WE A0 - A9 A10 DIS AP HIGH CA EN AP BA0,1 BA CA=Column Address BA=Bank Address EN AP=Enable Autoprecharge DIS AP=Disable Autoprecharge Don't Care Etron Confidential 16 Rev.1.3 May 2009 EtronTech Figure 7. Read Burst Required CAS Latencies (CL=2) CK CK EM6AB160TSA COMMAND READ NOP NOP NOP NOP NOP ADDRESS Bank A, Col n CL=2 DQS DQ DO n DO n=Data Out from column n Burst Length=4 3 subsequent elements of Data Out appear in the programmed order following DO n Don't Care Read Burst Required CAS Latencies (CL=2.5) CK CK COMMAND READ NOP NOP NOP NOP NOP ADDRESS Bank A, Col n CL=2.5 DQS DQ DO n DO n=Data Out from column n Burst Length=4 3 subsequent elements of Data Out appear in the programmed order following DO n Don't Care Etron Confidential 17 Rev.1.3 May 2009 EtronTech Read Burst Required CAS Latencies (CL=3) CK CK EM6AB160TSA COMMAND READ NOP NOP NOP NOP NOP ADDRESS Bank A, Col n CL=3 DQS DQ DO n DO n=Data Out from column n Burst Length=4 3 subsequent elements of Data Out appear in the programmed order following DO n Don't Care Etron Confidential 18 Rev.1.3 May 2009 EtronTech CK CK EM6AB160TSA Figure 8. Consecutive Read Bursts Required CAS Latencies (CL=2) COMMAND READ NOP READ NOP NOP NOP ADDRESS Bank, Col n CL=2 Bank, Col o DQS DQ DO n DO n DO n (or o)=Data Out from column n (or column o) Burst Length=4 or 8 (if 4, the bursts are concatenated; if 8, the second burst interrupts the first) 3 subsequent elements of Data Out appear in the programmed order following DO n 3 (or 7) subsequent elements of Data Out appear in the programmed order following DO o Read commands shown must be to the same device Don't Care Etron Confidential 19 Rev.1.3 May 2009 EtronTech Consecutive Read Bursts Required CAS Latencies (CL=2.5) CK CK EM6AB160TSA COMMAND READ NOP READ NOP NOP NOP ADDRESS Bank, Col n CL=2.5 Bank, Col o DQS DQ DO n DO o DO n (or o)=Data Out from column n (or column o) Burst Length=4 or 8 (if 4, the bursts are concatenated; if 8, the second burst interrupts the first) 3 subsequent elements of Data Out appear in the programmed order following DO n 3 (or 7) subsequent elements of Data Out appear in the programmed order following DO o Read commands shown must be to the same device Don't Care Etron Confidential 20 Rev.1.3 May 2009 EtronTech Consecutive Read Bursts Required CAS Latencies (CL=3) CK CK EM6AB160TSA COMMAND READ NOP READ NOP NOP NOP ADDRESS Bank, Col n CL=3 Bank, Col o DQS DQ DO n DO o DO n (or o)=Data Out from column n (or column o) Burst Length=4 or 8 (if 4, the bursts are concatenated; if 8, the second burst interrupts the first) 3 subsequent elements of Data Out appear in the programmed order following DO n 3 (or 7) subsequent elements of Data Out appear in the programmed order following DO o Read commands shown must be to the same device Don't Care Etron Confidential 21 Rev.1.3 May 2009 EtronTech CK CK EM6AB160TSA Figure 9. Non-Consecutive Read Bursts Required CAS Latencies (CL=2) COMMAND READ NOP NOP READ NOP NOP ADDRESS Bank, Col n CL=2 Bank, Col o DQS DQ DO n DO o DO n (or o)=Data Out from column n (or column o) Burst Length=4 3 subsequent elements of Data Out appear in the programmed order following DO n (and following DO o) Don't Care Non-Consecutive Read Bursts Required CAS Latencies (CL=2.5) CK CK COMMAND READ NOP NOP READ NOP NOP NOP ADDRESS Bank, Col n Bank, Col o CL=2.5 DQS DQ DO n DO o DO n (or o)=Data Out from column n (or column o) Burst Length=4 3 subsequent elements of Data Out appear in the programmed order following DO n (and following DO o) Don't Care Etron Confidential 22 Rev.1.3 May 2009 EtronTech Non-Consecutive Read Bursts Required CAS Latencies (CL=3) CK CK EM6AB160TSA COMMAND READ NOP NOP READ NOP NOP NOP ADDRESS Bank, Col n CL=3 Bank, Col o DQS DQ DO n (or o)=Data Out from column n (or column o) Burst Length=4 3 subsequent elements of Data Out appear in the programmed order following DO n (and following DO o) DO n DO o Don't Care Etron Confidential 23 Rev.1.3 May 2009 EtronTech CK CK EM6AB160TSA Figure 10. Random Read Accesses Required CAS Latencies (CL=2) COMMAND READ READ READ READ NOP NOP ADDRESS Bank, Col n Bank, Col o Bank, Col p Bank, Col q CL=2 DQS DQ DO n DO n' DO o DO o' DO p DO p' DO q DO n, etc. =Data Out from column n, etc. n', etc. =the next Data Out following DO n, etc. according to the programmed burst order Burst Length=2,4 or 8 in cases shown. If burst of 4 or 8, the burst is interrupted Reads are to active rows in any banks Don't Care Random Read Accesses Required CAS Latencies (CL=2.5) CK CK COMMAND READ READ READ READ NOP NOP ADDRESS Bank, Col n Bank, Col o Bank, Col p Bank, Col q CL=2.5 DQS DQ DO n DO n' DO o DO o' DO p DO p' DO n, etc. =Data Out from column n, etc. n', etc. =the next Data Out following DO n, etc. according to the programmed burst order Burst Length=2,4 or 8 in cases shown. If burst of 4 or 8, the burst is interrupted Reads are to active rows in any banks Don't Care Etron Confidential 24 Rev.1.3 May 2009 EtronTech Random Read Accesses Required CAS Latencies (CL=3) CK CK EM6AB160TSA COMMAND READ READ READ READ NOP NOP ADDRESS Bank, Col n Bank, Col o Bank, Col p Bank, Col q CL=3 DQS DQ DO n DO n' DO o DO o' DO p DO n, etc. =Data Out from column n, etc. n', etc. =the next Data Out following DO n, etc. according to the programmed burst order Burst Length=2,4 or 8 in cases shown. If burst of 4 or 8, the burst is interrupted Reads are to active rows in any banks Don't Care Etron Confidential 25 Rev.1.3 May 2009 EtronTech CK CK EM6AB160TSA Figure 11. Terminating a Read Burst Required CAS Latencies (CL=2) COMMAND READ NOP BST NOP NOP NOP ADDRESS Bank A, Col n CL=2 DQS DQ DO n DO n = Data Out from column n Cases shown are bursts of 8 terminated after 4 data elements 3 subsequent elements of Data Out appear in the programmed order following DO n Don't Care Terminating a Read Burst Required CAS Latencies (CL=2.5) CK CK COMMAND READ NOP BST NOP NOP NOP ADDRESS Bank A, Col n CL=2.5 DQS DQ DO n DO n = Data Out from column n Cases shown are bursts of 8 terminated after 4 data elements 3 subsequent elements of Data Out appear in the programmed order following DO n Don't Care Etron Confidential 26 Rev.1.3 May 2009 EtronTech Terminating a Read Burst Required CAS Latencies (CL=3) CK CK EM6AB160TSA COMMAND READ NOP BST NOP NOP NOP ADDRESS Bank A, Col n CL=3 DQS DQ DO n DO n = Data Out from column n Cases shown are bursts of 8 terminated after 4 data elements 3 subsequent elements of Data Out appear in the programmed order following DO n Don't Care Etron Confidential 27 Rev.1.3 May 2009 EtronTech Figure 12. Read to Write Required CAS Latencies (CL=2) CK CK COMMAND READ BST NOP WRITE EM6AB160TSA NOP NOP ADDRESS Bank, Col n CL=2 Bank, Col o tDQSS min DQS DQ DM DO n (or o)= Data Out from column n (or column o) Burst Length= 4 in the cases shown (applies for bursts of 8 as well; if burst length is 2, the BST command shown can be NOP) 1 subsequent element of Data Out appears in the programmed order following DO n Data in elements are applied following DI o in the programmed order DO n DI o Don't Care Etron Confidential 28 Rev.1.3 May 2009 EtronTech Read to Write Required CAS Latencies (CL=2.5) CK CK COMMAND READ BST NOP NOP EM6AB160TSA WRITE NOP ADDRESS Bank, Col n CL=2.5 Bank, Col o tDQSS min DQS DQ DM DO n (or o)= Data Out from column n (or column o) Burst Length= 4 in the cases shown (applies for bursts of 8 as well; if burst length is 2, the BST command shown can be NOP) 1 subsequent element of Data Out appears in the programmed order following DO n Data in elements are applied following DI o in the programmed order DO n DI o Don't Care Etron Confidential 29 Rev.1.3 May 2009 EtronTech Read to Write Required CAS Latencies (CL=3) CK CK COMMAND READ BST NOP NOP EM6AB160TSA WRITE NOP ADDRESS Bank, Col n CL=3 Bank, Col o tDQSS min DQS DQ DO n DI o DM DO n (or o)= Data Out from column n (or column o) Burst Length= 4 in the cases shown (applies for bursts of 8 as well; if burst length is 2, the BST command shown can be NOP) 1 subsequent element of Data Out appears in the programmed order following DO n Data in elements are applied following DI o in the programmed order Don't Care Etron Confidential 30 Rev.1.3 May 2009 EtronTech Figure 13. Read to Precharge Required CAS Latencies (CL=2) CK CK EM6AB160TSA COMMAND READ NOP PRE NOP NOP ACT tRP ADDRESS Bank A, Col n CL=2 Bank (a or all) Bank A, Row DQS DQ DO n DO n = Data Out from column n Cases shown are either uninterrupted bursts of 4, or interrupted bursts of 8 3 subsequent elements of Data Out appear in the programmed order following DO n Precharge may be applied at (BL/2) tCK after the READ command Note that Precharge may not be issued before tRAS ns after the ACTIVE command for applicable banks The Active command may be applied if tRC has been met Don't Care Etron Confidential 31 Rev.1.3 May 2009 EtronTech Read to Precharge Required CAS Latencies (CL=2.5) CK CK EM6AB160TSA COMMAND READ NOP PRE NOP NOP ACT tRP ADDRESS Bank A, Col n Bank (a or all) Bank A, Row CL=2.5 DQS DQ DO n DO n = Data Out from column n Cases shown are either uninterrupted bursts of 4, or interrupted bursts of 8 3 subsequent elements of Data Out appear in the programmed order following DO n Precharge may be applied at (BL/2) tCK after the READ command Note that Precharge may not be issued before tRAS ns after the ACTIVE command for applicable banks The Active command may be applied if tRC has been met Don't Care Etron Confidential 32 Rev.1.3 May 2009 EtronTech Read to Precharge Required CAS Latencies (CL=3) CK CK EM6AB160TSA COMMAND READ NOP PRE NOP NOP ACT tRP ADDRESS Bank A, Col n CL=3 Bank (a or all) Bank A, Row DQS DQ DO n DO n = Data Out from column n Cases shown are either uninterrupted bursts of 4, or interrupted bursts of 8 3 subsequent elements of Data Out appear in the programmed order following DO n Precharge may be applied at (BL/2) tCK after the READ command Note that Precharge may not be issued before tRAS ns after the ACTIVE command for applicable banks The Active command may be applied if tRC has been met Don't Care Etron Confidential 33 Rev.1.3 May 2009 EtronTech Figure 14. Write Command CK CK CKE CS RAS CAS WE A0 - A9 A10 DIS AP EM6AB160TSA HIGH CA EN AP BA0,1 BA CA=Column Address BA=Bank Address EN AP=Enable Autoprecharge DIS AP=Disable Autoprecharge Don't Care Etron Confidential 34 Rev.1.3 May 2009 EtronTech Figure 15. Write Max DQSS T0 CK CK COMMAND WRITE EM6AB160TSA T1 T2 T3 T4 T5 T6 T7 NOP NOP NOP ADDRESS Bank A, Col n tDQSS max DQS DQ DM DI n = Data In for column n 3 subsequent elements of Data In are applied in the programmed order following DI n A non-interrupted burst of 4 is shown A10 is LOW with the WRITE command (AUTO PRECHARGE disabled) DI n Don't Care Etron Confidential 35 Rev.1.3 May 2009 EtronTech Figure 16. Write Min DQSS T0 CK CK COMMAND WRITE EM6AB160TSA T1 T2 T3 T4 T5 T6 NOP NOP NOP ADDRESS Bank A, Col n tDQSS min DQS DQ DM DI n DI n = Data In for column n 3 subsequent elements of Data In are applied in the programmed order following DI n A non-interrupted burst of 4 is shown A10 is LOW with the WRITE command (AUTO PRECHARGE disabled) Don't Care Etron Confidential 36 Rev.1.3 May 2009 EtronTech Figure 17. Write Burst Nom, Min, and Max tDQSS T0 CK CK COMMAND WRITE EM6AB160TSA T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 NOP NOP NOP NOP NOP ADDRESS Bank , Col n tDQSS (nom) DQS DQ DI n DM tDQSS (min) DQS DQ DI n DM tDQSS (max) DQS DQ DI n DM DI n = Data In for column n 3 subsequent elements of Data are applied in the programmed order following DI n A non-interrupted burst of 4 is shown A10 is LOW with the WRITE command (AUTO PRECHARGE disabled) DM=UDM & LDM Don't Care Etron Confidential 37 Rev.1.3 May 2009 EtronTech Figure 18. Write to Write Max tDQSS T0 CK CK COMMAND WRITE EM6AB160TSA T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 NOP WRITE NOP NOP NOP ADDRESS Bank , Col n Bank , Col o tDQSS (max) DQS DQ DI n DI o DM DI n , etc. = Data In for column n,etc. 3 subsequent elements of Data In are applied in the programmed order following DI n 3 subsequent elements of Data In are applied in the programmed order following DI o Non-interrupted bursts of 4 are shown DM= UDM & LDM Don't Care Etron Confidential 38 Rev.1.3 May 2009 EtronTech Figure 19. Write to Write Max tDQSS, Non Consecutive T0 CK CK COMMAND WRITE EM6AB160TSA T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 NOP NOP WRITE NOP NOP ADDRESS Bank Col n Bank Col o tDQSS (max) DQS DQ DI n DI o DM DI n, etc. = Data In for column n, etc. 3 subsequent elements of Data In are applied in the programmed order following DI n 3 subsequent elements of Data In are applied in the programmed order following DI o Non-interrupted bursts of 4 are shown DM= UDM & LDM Don't Care Etron Confidential 39 Rev.1.3 May 2009 EtronTech Figure 20. Random Write Cycles Max tDQSS T0 CK CK COMMAND WRITE WRITE WRITE WRITE EM6AB160TSA T1 T2 T3 T4 T5 T6 T7 T8 T9 WRITE ADDRESS Bank Col n Bank Col o Bank Col p Bank Col q Bank Col r tDQSS (max) DQS DQ DI n DI n DI o DI o DI p DI p DI q DI q DM DI n, etc. = Data In for column n, etc. n', etc. = the next Data In following DI n, etc. according to the programmed burst order Programmed Burst Length 2, 4, or 8 in cases shown If burst of 4 or 8, the burst would be truncated Each WRITE command may be to any bank and may be to the same or different devices DM= UDM & LDM Don't Care Etron Confidential 40 Rev.1.3 May 2009 EtronTech Figure 21. Write to Read Max tDQSS Non Interrupting T0 CK CK COMMAND WRITE EM6AB160TSA T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 T12 NOP NOP NOP tWTR READ NOP NOP ADDRESS Bank Col n tDQSS (max) Bank Col o CL=3 DQS DQ DI n DM DI n, etc. = Data In for column n, etc. 1 subsequent elements of Data In are applied in the programmed order following DI n A non-interrupted burst of 4 is shown tWTR is referenced from the first positive CK edge after the last Data In Pair A10 is LOW with the WRITE command (AUTO PRECHARGE is disabled) The READ and WRITE commands are to the same devices but not necessarily to the same bank DM= UDM & LDM Don't Care Etron Confidential 41 Rev.1.3 May 2009 EtronTech Figure 22. Write to Read Max tDQSS Interrupting T0 CK CK COMMAND WRITE EM6AB160TSA T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 T12 NOP NOP NOP tWTR READ NOP ADDRESS Bank Col n Bank Col o CL=3 tDQSS (max) DQS DQ DI n DM DI n, etc. = Data In for column n, etc. 1 subsequent elements of Data In are applied in the programmed order following DI n An interrupted burst of 8 is shown, 2 data elements are written tWTR is referenced from the first positive CK edge after the last Data In Pair A10 is LOW with the WRITE command (AUTO PRECHARGE is disabled) The READ and WRITE commands are to the same devices but not necessarily to the same bank DM= UDM & LDM Don't Care Etron Confidential 42 Rev.1.3 May 2009 EtronTech T0 CK CK COMMAND WRITE EM6AB160TSA Figure 23. Write to Read Max tDQSS, ODD Number of Data, Interrupting T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 T12 NOP NOP NOP tWTR READ NOP NOP ADDRESS Bank Col n Bank Col o CL=3 tDQSS (max) DQS DQ DI n DM DI n = Data In for column n An interrupted burst of 8 is shown, 3 data elements are written tWTR is referenced from the first positive CK edge after the last Data In Pair (not the last desired Data In element) A10 is LOW with the WRITE command (AUTO PRECHARGE is disabled) The READ and WRITE commands are to the same devices but not necessarily to the same bank DM= UDM & LDM Don't Care Etron Confidential 43 Rev.1.3 May 2009 EtronTech Figure 24. Write to Precharge Max tDQSS, NON- Interrupting T0 CK CK COMMAND WRITE EM6AB160TSA T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 NOP NOP NOP NOP tWR PRE ADDRESS Bank a, Col n Bank (a or al) tRP tDQSS (max) DQS DQ DI n DM DI n = Data In for column n 1 subsequent elements of Data In are applied in the programmed order following DI n A non-interrupted burst of 4 is shown tWR is referenced from the first positive CK edge after the last Data In Pair A10 is LOW with the WRITE command (AUTO PRECHARGE is disabled) DM= UDM & LDM Don't Care Etron Confidential 44 Rev.1.3 May 2009 EtronTech Figure 25. Write to Precharge Max tDQSS, Interrupting T0 CK CK COMMAND WRITE EM6AB160TSA T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 NOP NOP NOP tWR PRE NOP ADDRESS Bank a, Col n Bank (a or all) tDQSS (max) *2 tRP DQS DQ DI n DM *1 *1 *1 *1 DI n = Data In for column n An interrupted burst of 4 or 8 is shown, 2 data elements are written tWR is referenced from the first positive CK edge after the last Data In Pair A10 is LOW with the WRITE command (AUTO PRECHARGE is disabled) *1 = can be don't care for programmed burst length of 4 *2 = for programmed burst length of 4, DQS becomes don't care at this point DM= UDM & LDM Don't Care Etron Confidential 45 Rev.1.3 May 2009 EtronTech T0 CK CK COMMAND WRITE EM6AB160TSA Figure 26. Write to Precharge Max tDQSS ODD Number of Data Interrupting T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 NOP NOP NOP tWR PRE NOP ADDRESS Bank a, Col n Bank (a or all) tDQSS (max) *2 tRP DQS DQ DI n DM *1 *1 *1 *1 DI n = Data In for column n An interrupted burst of 4 or 8 is shown, 1 data element is written tWR is referenced from the first positive CK edge after the last Data In Pair A10 is LOW with the WRITE command (AUTO PRECHARGE is disabled) *1 = can be don't care for programmed burst length of 4 *2 = for programmed burst length of 4, DQS becomes don't care at this point DM= UDM & LDM Don't Care Etron Confidential 46 Rev.1.3 May 2009 EtronTech Figure 27. Precharge Command CK CK CKE CS RAS CAS WE A0-A9, A11,A12 ALL BANKS EM6AB160TSA HIGH A10 ONE BANK BA0,1 BA BA= Bank Address (if A10 is LOW, otherwise don't care) Don't Care Etron Confidential 47 Rev.1.3 May 2009 EtronTech Figure 28. Power-Down T0 CK CK tIS CKE tIS T1 T2 T3 T4 Tn Tn+1 Tn+2 EM6AB160TSA Tn+3 Tn+4 Tn+5 Tn+6 COMMAND VALID NOP NOP VALID No column access in progress Enter power-down mode Exit power-down mode Don't Care Figure 29. Clock Frequency Change in Precharge T0 CK CK T1 T2 T4 Tx Tx+1 Ty Ty+1 Ty+2 Ty+3 Ty+4 Tz CMD CKE NOP NOP Frequency Change Occurs here NOP DLL RESET NOP NOP Valid tIS tRP Minmum 2 clocks Required before Changing frequency Stable new clock Before power down exit 200 Clocks Etron Confidential 48 Rev.1.3 May 2009 EtronTech Figure 30. Data input (Write) Timing tDQSH DQS tDS DQ tDH tDS DM tDH DI n = Data In for column n Burst Length = 4 in the case shown 3 subsequent elements of Data In are applied in the programmed order following DI n DI n EM6AB160TSA tDQSL Don't Care Figure 31. Data Output (Read) Timing tCH CK CK DQS tCL DQ tDQSQ max tDQSQ tQH max tQH Burst Length = 4 in the case shown Etron Confidential 49 Rev.1.3 May 2009 EtronTech Figure 32. Initialize and Mode Register Sets VDD VDDQ tVDT>=0 EM6AB160TSA VTT (system*) VREF tCK tCH tCL tIS tIH CK CK CKE tIS tIH COMMAND NOP PRE EMRS MRS PRE AR AR MRS ACT DM tIS tIH A0-A9, A11,A12 CODE CODE ALL BANKS CODE RA ALL BANKS tIS tIH CODE CODE A10 CODE RA tIS tIH BA0,BA1 High-Z tIS tIH BA0=H BA1=L BA0=L BA1=L tIS tIH BA0=L BA1=L BA DQS DQ T=200s High-Z **tMRD Extended mode Register set **tMRD tRP 200 cycles of CK** Load Mode Register, Reset DLL (with A8=H) Load Mode Register, (with A8=L) tRFC tRFC **tMRD Power-up: VDD and CLK stable *=VTT is not applied directly to the device, however tVTD must be greater than or equal to zero to avoid device latch-up **=tMRD is required before any command can be applied, and 200 cycles of CK are required before any executable command can be applied The two Auto Refresh commands may be moved to follow the first MRS but precede the second PRECHARGE ALL command Don't Care Etron Confidential 50 Rev.1.3 May 2009 EtronTech Figure 33. Power Down Mode tCK CK CK tIS tIH CKE tIS tIH COMMAND VALID* EM6AB160TSA tCH tCL tIS tIS NOP NOP VALID tIS tIH ADDR VALID VALID DQS DQ DM Enter power-down mode Exit power-down mode No column accesses are allowed to be in progress at the time Power-Down is entered *=If this command is a PRECHARGE ALL (or if the device is already in the idle state) then the Power-Down mode shown is Precharge Power Down. If this command is an ACTIVE (or if at least one row is already active) then the Power-Down mode shown is active Power Down. Don't Care Etron Confidential 51 Rev.1.3 May 2009 EtronTech Figure 34. Auto Refresh Mode tCK CK CK EM6AB160TSA tCH tCL tIS tIH CKE VALID VALID tIS tIH COMMAND NOP PRE NOP NOP AR NOP AR NOP NOP ACT A0-A9 RA A11,A12 RA ALL BANKS A10 ONE BANKS RA tIS tIH BA0,BA1 *Bank(s) RA DQS DQ DM tRP tRFC tRFC * = Don't Care , if A10 is HIGH at this point; A10 must be HIGH if more than one bank is active (i.e., must precharge all active banks) PRE = PRECHARGE, ACT = ACTIVE, RA = Row Address, BA = Bank Address, AR = AUTOREFRESH NOP commands are shown for ease of illustration; other valid commands may be possible after tRFC DM, DQ and DQS signals are all Don't Care /High-Z for operations shown Don't Care Etron Confidential 52 Rev.1.3 May 2009 EtronTech Figure 35. Self Refresh Mode tCK tCH CK CK tIS tIH CKE tIS tIH COMMAND NOP Clock must be stable before Exiting Self Refresh mode EM6AB160TSA tCL tIS tIS AR NOP VALID tIS tIH ADDR VALID DQS DQ DM tXSNR/ tXSRD** Exit Self Refresh mode tRP* Enter Self Refresh mode * = Device must be in the All banks idle state prior to entering Self Refresh mode ** = tXSNR is required before any non-READ command can be applied, and tXSRD (200 cycles of CK) is required before a READ command can be applied. Don't Care Etron Confidential 53 Rev.1.3 May 2009 EtronTech Figure 36. Read without Auto Precharge tCK CK CK EM6AB160TSA tCH tCL tIS tIH CKE tIH VALID VALID VALID tIS tIH COMMAND NOP READ NOP PRE NOP NOP ACT NOP NOP NOP tIS tIH A0-A9 Col n RA A11,A12 tIS A10 DIS AP ONE BANKS RA tIH ALL BANKS RA tIS tIH BA0,BA1 Bank X CL=3 DM Case 1: tAC/tDQSCK=min *Bank X Bank X tRP tDQSCK tRPRE DQS min tRPST tLZ DQ min DO n tLZ Case 2: tAC/tDQSCK=max min tAC min max tDQSCK tRPRE tRPST DQS max DQ max DO n = Data Out from column n Burst Length = 4 in the case shown 3 subsequent elements of Data Out are provided in the programmed order following DO n DIS AP = Disable Autoprecharge *= Don't Care , if A10 is HIGH at this point tLZ DO n tHZ tAC max tLZ max PRE = PRECHARGE, ACT = ACTIVE, RA = Row Address, BA = Bank Address, AR = AUTOREFRESH NOP commands are shown for ease of illustration; other commands may be valid at these times Precharge may not be issued before tRAS ns after the ACTIVE command for applicable banks Don't Care Etron Confidential 54 Rev.1.3 May 2009 EtronTech Figure 37. Read with Auto Precharge tCK CK CK EM6AB160TSA tCH tCL tIS tIH CKE tIH VALID VALID VALID tIS tIH COMMAND NOP READ NOP NOP NOP NOP ACT NOP NOP NOP tIS tIH A0-A9 Col n RA A11,A12 RA EN AP A10 tIS tIH RA tIS tIH BA0,BA1 Bank X CL=3 DM Case 1: tAC/tDQSCK=min tRP Bank X tDQSCK min tRPST tRPRE DQS tLZ min DO n DQ tLZ Case 2: tAC/tDQSCK=max min tAC min tDQSCK max tRPST tRPRE DQS max DQ max DO n = Data Out from column n Burst Length = 4 in the case shown 3 subsequent elements of Data Out are provided in the programmed order following DO n EN AP = Enable Autoprecharge ACT = ACTIVE, RA = Row Address NOP commands are shown for ease of illustration; other commands may be valid at these times The READ command may not be issued until tRAP has been satisfied. If Fast Autoprecharge is supported, tRAP = tRCD, else the READ may not be issued prior to tRASmin (BL*tCK/2) tLZ DO n tHZ tAC max tLZ max Don't Care Etron Confidential 55 Rev.1.3 May 2009 EtronTech Figure 38. Bank Read Access tCK CK CK EM6AB160TSA tCH tCL tIS tIH CKE tIS tIH COMMAND NOP ACT NOP NOP NOP READ NOP PRE NOP NOP ACT tIS tIH A0-A9 RA Col n RA A11,A12 RA tIS tIH RA ALL BANKS A10 RA DIS AP ONE BANKS RA tIS tIH BA0,BA1 Bank X Bank X *Bank X Bank X tRC tRAS tRCD DM Case 1: tAC/tDQSCK=min CL=3 tRP tDQSCK tRPRE DQS min tRPST DQ min tLZ DO n min tLZ Case 2: tAC/tDQSCK=max DQS max DQ min tAC tDQSCK max tRPRE tLZ tRPST tHZ max DO n max tLZ DO n = Data Out from column n Burst Length = 4 in the case shown 3 subsequent elements of Data Out are provided in the programmed order following DO n DIS AP = Disable Autoprecharge *= Don't Care , if A10 is HIGH at this point PRE = PRECHARGE, ACT = ACTIVE, RA = Row Address, BA = Bank Address NOP commands are shown for ease of illustration; other commands may be valid at these times Note that tRCD > tRCD MIN so that the same timing applies if Autoprecharge is enabled (in which case tRAS would be limiting) max tAC Don't Care Etron Confidential 56 Rev.1.3 May 2009 EtronTech Figure 39. Write without Auto Precharge tCK CK CK EM6AB160TSA tCH tCL tIH VALID tIS tIH CKE tIS tIH COMMAND NOP WRITE NOP NOP NOP NOP PRE NOP NOP ACT tIS tIH A0-A9 Col n RA A11,A12 tIS tIH A10 DIS AP ONE BANKS RA ALL BANKS RA tIS tIH BA0,BA1 Bank X *Bank X BA Case 1: tDQSS=min DQS tDQSS tDSH tDQSH tDSH tRP tWR tWPST tWPRES tDQSL DI n tWPRE DQ DM tDSS Case 2: tDQSS=max DQS tDSS tWPST tDQSS tWPRES tWPRE tDQSH tDQSL DI n DQ DM DI n = Data In from column n Burst Length = 4 in the case shown 3 subsequent elements of Data In are provided in the programmed order following DI n DIS AP = Disable Autoprecharge *= Don't Care , if A10 is HIGH at this point PRE = PRECHARGE, ACT = ACTIVE, RA = Row Address, BA = Bank Address, AR = AUTOREFRESH NOP commands are shown for ease of illustration; other commands may be valid at these times Although tDQSS is drawn only for the first DQS rising edge, each rising edge of DQS must fall within the + 25% window of the corresponding positive clock edge Precharge may not be issued before tRAS ns after the ACTIVE command for applicable banks Don't Care Etron Confidential 57 Rev.1.3 May 2009 EtronTech Figure 40. Write with Auto Precharge tCK CK CK EM6AB160TSA tCH tCL tIS tIH CKE VALID VALID VALID tIS tIH COMMAND NOP WRITE NOP NOP NOP NOP NOP NOP NOP ACT tIS tIH A0-A9 Col n RA A11,A12 RA DIS AP A10 tIS tIH BA0,BA1 Bank X RA BA tDAL Case 1: tDQSS=min DQS tDQSS tDSH tDQSH tDSH tWPST tWPRES tWPRE DQ DI n tDQSL DM Case 2: tDQSS=max DQS tDQSS tDSS tDQSH tDSS tWPST tWPRES tWPRE DQ DI n tDQSL DM DI n = Data In from column n Burst Length = 4 in the case shown 3 subsequent elements of Data Out are provided in the programmed order following DI n EN AP = Enable Autoprecharge ACT = ACTIVE, RA = Row Address, BA = Bank Address NOP commands are shown for ease of illustration; other commands may be valid at these times Although tDQSS is drawn only for the first DQS rising edge, each rising edge of DQS must fall within the + 25% window of the corresponding positive clock edge Don't Care Etron Confidential 58 Rev.1.3 May 2009 EtronTech Figure 41. Bank Write Access tCK CK CK EM6AB160TSA tCH tCL tIS tIH CKE tIS tIH COMMAND NOP ACT NOP NOP WRITE NOP NOP NOP NOP PRE tIS tIH A0-A9 RA Col n A11,A12 RA tIS tIH ALL BANKS A10 RA DIS AP ONE BANK tIS tIH BA0,BA1 Bank X Bank X *Bank X tRAS tRCD Case 1: tDQSS=min DQS tWR tDQSS tDSH tDQSH tDSH tWPST tWPRES tWPRE DQ DI n tDQSL DM Case 2: tDQSS=max DQS tDSS tDQSS tDQSH tDSS tWPST tWPRES tWPRE DQ DI n tDQSL DM DI n = Data In from column n Burst Length = 4 in the case shown 3 subsequent elements of Data Out are provided in the programmed order following DI n DIS AP = Disable Autoprecharge *= Don't Care , if A10 is HIGH at this point PRE = PRECHARGE, ACT = ACTIVE, RA = Row Address, BA = Bank Address NOP commands are shown for ease of illustration; other commands may be valid at these times Although tDQSS is drawn only for the first DQS rising edge, each rising edge of DQS must fall within the + 25% window of the corresponding positive clock edge Precharge may not be issued before tRAS ns after the ACTIVE command for applicable banks Don't Care Etron Confidential 59 Rev.1.3 May 2009 EtronTech Figure 42. Write DM Operation tCK CK CK EM6AB160TSA tCH tCL tIS tIH CKE VALID tIS tIH COMMAND NOP WRITE NOP NOP NOP NOP PRE NOP NOP ACT tIS tIH A0-A9 Col n RA A11,A12 tIS A10 DIS AP ONE BANKS RA tIH ALL BANKS RA tIS tIH BA0,BA1 Case 1: tDQSS=min DQS Bank X *Bank X BA tDQSS tDSH tDQSH tDSH tRP tWPST tWR tWPRES tDQSL tWPRE DQ DI n DM tDSS Case 2: tDQSS=max DQS tDSS tWPST tDQSS tDQSH tWPRES tWPRE DI n tDQSL DQ DM DI n = Data In from column n Burst Length = 4 in the case shown 3 subsequent elements of Data In are provided in the programmed order following DI n DIS AP = Disable Autoprecharge *= Don't Care , if A10 is HIGH at this point PRE = PRECHARGE, ACT = ACTIVE, RA = Row Address, BA = Bank Address NOP commands are shown for ease of illustration; other commands may be valid at these times Although tDQSS is drawn only for the first DQS rising edge, each rising edge of DQS must fall within the + 25% window of the corresponding positive clock edge Precharge may not be issued before tRAS ns after the ACTIVE command for applicable banks Don't Care Etron Confidential 60 Rev.1.3 May 2009 EtronTech Figure 43. 66 Pin TSOP II Package Outline Drawing Information Units: mm D EM6AB160TSA C C HE E A2 A1 S e b A F (TYP) Symbol A A1 A2 b e C D E HE L L1 F S Dimension in mm Min Nom Max --0.05 0.9 0.22 --0.095 22.09 10.03 11.56 0.40 ----0 --------1.0 --0.65 0.125 22.22 10.16 11.76 0.5 0.8 0.25 --0.71 --1.2 0.2 1.1 0.45 --0.21 22.35 10.29 11.96 0.6 ----8 --0.10 Dimension in inch Min Nom Max --0.002 0.035 0.009 --0.004 0.87 0.395 0.455 0.016 ----0 --------0.039 --0.026 0.005 0.875 0.4 0.463 0.02 0.032 0.01 --0.028 --0.047 0.008 0.043 0.018 --0.008 0.88 0.405 0.471 0.024 ----8 --0.004 y Etron Confidential D 61 Rev.1.3 L L1 May 2009 |
Price & Availability of EM6AB160TSA-5G
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |