![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Embedded Power for Business-Critical Continuity NLP250 Medical Series Single Output Rev.10.1.09_181 NLP250 Medical Series 1 of 4 Total Power: 250W Input Voltage: 85-264VAC # of Outputs: Single Special Features * Medicalsafeties * ActivePFCand EN61000-3-2 compliant * 250Wonmainchannelwith forced air * Lowprofilefits1Uapplications * U-Channelformaximum thermalperformance * Optionalcover(CJsuffix) * 5Vstandbyoutput * 12Vfanoutput * Integratedcontroland monitoring features * Overcurrent,overvoltageand overtemperatureprotection * CompliancetoEN55022-B conducted noise standard * DualACfuses * RoHScompliant * 2yearwarranty ElectricalSpecifications Input Inputvoltagerange: Inputfrequencyrange: Inputsurgecurrent: Safetygroundleakagecurrent: Inputcurrent: Inputfuse: 264Vac(coldstart) 264Vac,50Hz 120Vac@250W 230Vac@250W UL/IEC127 200LFMforcedair 250LFMwithcover Mainoutput Mainoutput Auxiliaryoutputs @120VacInput Mainoutput 50-100% Stepat0.5A/s Mainoutput Cyclic operation Singles 5Vsb 12V(fan) Universalinput 85-264Vac 47-63Hz 40Amax. 150A 2.78Arms 1.36Arms T6.4AH,250VacInliveand neutral 250watts 5% 2.0% 5.0% 2.0smax. 5.0%or250mV max.dev.,1msmax recoveryto1% 0.02%/C 115%,5% Continuous 0A 5V@1.0A 12V@0.3A Output Maximumpower: Adjustmentrange: Totalregulation: (lineandload) Turn-ondelay: Transientresponse: Safety * * * * VDE0750/EN60950 IEC950/IEC60601-1 FileNo.1177400-3336-0759 UL60601-1 FileNo.E186249 CertificateNo.40014041 CBRefDE1-36628 Temperaturecoefficient: Overvoltageprotection: Shortcircuitprotection: Minimumoutputcurrent: Auxiliaryoutputs: (SeeNote8,page3) Allspecificationsaretypicalatnominalinput,fullloadat25Cunlessotherwisestated Embedded Power for Business-Critical Continuity Rev.10.1.09_181 NLP250 Medical Series 2 of 4 EMCCharacteristics(5) Conductedemissions: Harmoniccurrentcorrection: Voltageflicker: ESDair: ESDcontact: Radiatedimmunity: Fasttransients: Surge: Conductedimmunity: Voltagedips: EN55022,FCCpart15 EN61000-3-2 EN61000-3-3 EN61000-4-2 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-11 85Vac@50Hz 115Vac@250W 230Vac@250W Input/output Input/chassis LevelB Compliant Compliant Level3 Level3 Level3 Level3 Level3 Level3 Compliant 20ms@250W 84%typ. 86%typ. 4000Vac 2000Vac 650g(22oz) TelcordiaSR-332 MIL-HDBK-217F 317,000hoursmin. 158,000hoursmin. GeneralSpecifications Hold-uptime: Efficiency: Isolationvoltage: Safetyapprovals(seeNote6,page3): Weight: MTBF(@25C): UL/cULUL60601-1,VDEEN60601-1,CAN/CSA22.2No.601-1 EnvironmentalSpecifications Thermalperformance: Operatingambient, (Seederatingcurve) Non-operating 0Cto50Cambient, 200LFMforcedair 250LFMwithcover 0Cto50Cambient, 0Cto40Cwithcover Convectioncooled 50Cto70Cambient, Convectioncooled Relativehumidity: Altitude: Vibration(SeeNote7,page3): Shock: Non-condensing Operating Non-operating 5-500Hz PerMIL-STD-810E Deratelinearly to50%load 5-95%RH 10,000feetmax. 30,000feetmax. 2.5Grmspeak 516.4PartIV 175W -40Cto+85C 250W 0Cto+70C Embedded Power for Business-Critical Continuity OrderingInformation OutputVoltage 12V 24V Notes Rev.10.1.09_181 NLP250 Medical Series of 4 Output Current Min 0A 0A Max(freeair)(1,4) Max(forcedair)(2,4) 14.6A 7.3A 21A 10.5A Ripple(3) 120mV 240mV TotalRegulation 2.0% 2.0% ModelNumbers(9,10) NLP250N-99S12J NLP250N-99S24J 1 Freeairconvection.Maximumcontinuousoutputpowernottoexceed175 W. RefertoFigure1forthederatingcurve. 2 200LFM(250LFMwithcover)forcedaircoolingfromthelongerside. Maximumcontinuousoutputpowernottoexceed250W. 3 Figure is peak-to-peak for room temperature rating. Output noise measurementsaremadeacrossa20MHzbandwidthusinga6inchtwisted pair,terminatedwitha10Ftantalumcapacitoranda0.1Fceramic capacitor. 4 CAUTION:Allowaminimumof1secondafterdisconnectinglinepowerwhen makingthermalmeasurements.Foroptimumreliabilitynopartoftheheatsink shouldexceed115Candnosemi-conductorcasetemperatureshouldexceed 120 C. 5 Noexternalfilteringrequiredduringconductedemissionstestingbutsome applicationsmayrequireadditionalfilteringtoachievesystemcompliance. CompliancewithradiatedEMIspecificationsmayrequiremountingina suitable enclosure. 6 Thisproductisonlyforinclusionbyprofessionalinstallerswithinother equipmentandmustnotbeoperatedasastandaloneproduct. 7 Threeorthogonalaxes,randomvibration10minutesforeachaxes,2.4G 8 5Vsb(standby)outputisavailablewheneverACispresent,regardlessof remoteON/OFFsignalstatus.12V(fan)presentwhenmainoutputispresent. 9 The`J'suffixindicatesthatthesepartsarePb-free(RoHS6/6)compliant. "CJ"suffixindicatescoveredRoHSversion. 10 NOTICE:Somemodelsdonotsupportalloptions.Pleasecontactyourlocal EmersonNetworkPowerrepresentativeorusetheon-linemodelnumber searchtoolathttp://www.PowerConversion.comtofindasuitablealternative. MechanicalDrawing CUSTOMER MOUNTING HOLES MAX. SCREW PENETRATION 0.08IN 6-32 J1 4.000 [101.60] E L N 1 J3 JP1 VR7 J4 J2 1.140 (28.96) 1 0.750 (19.05) M3.0 5.850 (148.59) 1 0.25 (6.35) 6.250 (158.75) M3.0 4 PLACES 7.000 [177.80] 6-32 4 PLACES 4.700 (119.38) 1.500 [38.10] 5.500 (139.70) BOTTOM VIEW 2.500 (63.50) Embedded Power for Business-Critical Continuity Figure1:DeratingCurve OutputPower(Watts) DERATING CURVE Output Power (Watts) All Models Forced Air 250 W 200 LFM (1.0 m/s) FORCED AIR COOLING 175 W 24 V Free Air Figure1b:DeratingCurveWithCover OutputPower(Watts) DERATING CURVE Output Power (Watts) WITH COVER All Models Forced Air Americas Rev.10.1.09_181 NLP250 Medical Series 4 of 4 250 W 250 LFM (1.25 m/s) FORCED AIR COOLING 175 W 24 V Free Air 12 V Free Air 5810VanAllenWay Carlsbad,CA92008 USA Telephone:+17609304600 Facsimile: +17609300698 12 V Free Air 125 W NATURAL FREE AIR CONVECTION COOLING 75 W 125 W NATURAL FREE AIR CONVECTION COOLING 87 W 75 W Europe (UK) 0W 0C 10 C 20 C 30 C 40 C 50 C 60 C 70 C 0W 0C 10 C 20 C 30 C 40 C 50 C 60 C 70 C WaterfrontBusinessPark MerryHill,Dudley WestMidlands,DY51LX UnitedKingdom Telephone:+44(0)1384842211 Facsimile: +44(0)1384843355 ConnectorandMatingConnectorTypes Asia (HK) Connector J1 J2 J3 Type MatingConnectorType Molex09-65-2058(5273series)voidpins Molex09-50-8051orequivalentwithMolex08-52-0113or 2and4orequivalent equivalentcrimpterminals Molex22-23-2021(6373series)or equivalent Molexterminalblock387007504or equivalent Molex22-23-2091(6373series)or equivalent Molex22-01-3027(2695series)orequivalentwithMolex 08-50-01113(2759series)orequivalentcrimpterminals Terminalblockcontains#6-32screwwithclamp washersuitableforwiresize12-22awg(0.5-2.5mm2). MaxTorquetp1.36Nm(12in.lb) Molex22-01-3097(2695series)orequivalentwithMolex 08-50-0113(2759series)orequivalentcrimpterminals 14/F,LuPlaza 2WingYipStreet KwunTong,Kowloon HongKong Telephone:+85221763333 Facsimile: +85221763888 Forglobalcontact,visit: www.PowerConversion.com techsupport.embeddedpower @emerson.com Whileeveryprecautionhasbeentakentoensure accuracyandcompletenessinthisliterature,Emerson NetworkPowerassumesnoresponsibility,anddisclaims allliabilityfordamagesresultingfromuseofthis information or for any errors or omissions. J4 Pin Connections J1 Pin 1 Pin 2 Pin 3 Ground/Earth Live Neutral Pin Connections Continued J2 Pin 1 Pin 2 +12V SGND Vo Vo RTN RTN +S -S LS PS OFF PS ON SGND PWOK 5Vsb DCOK FanVoltage Return +MainOutput +MainOutput MainReturn MainReturn +VoRemoteSense VoRemoteSense LoadShareSignal RemoteON/OFFsignalNO RemoteON/OFFsignalNC Signal Common PowerGood Stand-byVoltage DCPowerGoodSignal Emerson Network Power. Thegloballeaderinenabling business-critical continuity. ACPower Connectivity DCPower Embedded Computing Embedded Power Monitoring Outside Plant PowerSwitching&Controls Precision Cooling Racks&IntegratedCabinets Services Surge Protection EmersonNetworkPower.com EmersonNetworkPowerandtheEmerson Network Power logo are trademarks and servicemarksofEmersonElectricCo. (c)2009EmersonElectricCo. J3 Pin 1 Pin 2 Pin 3 Pin4 J4 Pin 1 Pin 2 Pin 3 Pin4 Pin5 Pin 6 Pin7 Pin 8 Pin9 |
Price & Availability of NLP250MEDICAL0910
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |