If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Issue: 01 Date: 2005-07-15 Specification AXIOM25 Oscillator type : OCXO in DIL14 package, Sinewave Output Parameter Frequency range Standard frequencies Frequency stability Initial tolerance vs. temperature (steady state) min. 10 typ. max. Unit MHz MHz ppm ppb ppb ppb ppb ppb C ppb ppb ppm ppm V V % k Condition 80 10 / 12.8 / 16.384 500 100 200 300 500 +60 10 20 0.5 5 3.15 4.75 operating temperature range vs. supply voltage variation vs. load change long term (aging) 1st year (Note 3) Frequency adjustment range Electronic Frequency Control (EFC) EFC voltage VC EFC slope (f / VC) EFC linearity EFC input impedance RF output Signal waveform Load Output amplitude Harmonic attenuation Warm-up time Supply voltage VS Current consumption (steady state) @ +25C Current consumption (warm-up) Enable/disable function Operable temperature range Storage temperature range Enclosure (see drawing) Weight Packing ESD Sensitivity -10 @+25C, VC= 2.5V Option II ="100" Option II ="200" Option II ="300" Option II ="500" Note 2 @ +40C, after 30 days 2 0.15 0.25 1.65 2.5 positive Option I = "33" Option I =50" 100 Sinus 50 +3 30 3.13 4.75 3.3 5.0 2 3.47 5.25 300 200 800 500 Ohm dBm dBc min V mA mA mA mA C C mm gram V ffinal/f0 < 0.1 ppm Option I = "33" Option I =50" Option I = "33" Option I =50" Option I = "33" Option I =50" -30 +75 -40 +85 20.7x13.1x8.5 max. 5 Palette or stick 1500 IEC 60679-3 CO 02 HBM as in IEC 610004-2 Notes: 1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated 2. Operating temperature range -20C to +70C on request 3. Aging of 0.2 ppm / 1st year on request Ordering Code: Model (Specification) Option I Option II AXIOM25 50 100 Frequency [MHz] 10.000 GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany AXIOM25 page 1(2) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: info@axtal.com Enclosure drawing Pin connections Pin # Symbol 1 VC 7 GND 8 RF OUT 14 VS Function Voltage Control (EFC) Ground RF Output Supply Voltage Environmental conditions Test Visual inspection, dimensions Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* Bump* Free fall* Vibration, sinusoidal* Rapid change of temperature Dry heat IEC 60068 Part ... IEC 60679-1 clause ... 4.3 4.6.2 4.6.3 Test conditions Enclosure styles as in IEC 60679-3 or 61837, if applicable Gross leak: Test Qc, Fine leak: Test Qk Test Ta (235 5)C Method 1 Test Tb Method 1A, 5s Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Eb, 4000 bumps per Axes, 40g, 6 ms Test Ed procedure 1, 2 drops from 1m height Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Test Na, 10 cycles at extremes of operating temperature range Test Ba, 16 h at upper temperature indicated by climatic category Test Db variant 1 severity b), 55C/95% r.H., 6 cycles Test Aa, 2 h at lower temperature indicated by climatic category st Sequence of 4.6.14, 4.6.15 (1 cycle), 4.6.16, 4.6.15 (5 cycles) Test Ca, 56 days 2-17 2-20 2-58 2-27 2-29 2-32 2-6 4.6.8 4.6.6 4.6.9 4.6.7 2-14 2-2 4.6.5 4.6.14 Damp heat, cyclic* Cold 2-30 2-1 4.6.15 4.6.16 Climatic sequence* Damp heat, steady state* Endurance tests - ageing - extended aging 1-7 2-3 4.6.17 4.6.18 4.7.1 4.7.2 30 days @ 85C, OCXO @25C 1000h, 2000h, 8000h @85C GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany AXIOM25 page 2(2) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: info@axtal.com |
Price & Availability of AXIOM25
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |