INSTALLATION AND MAINTENANCE INSTRUCTIONS ZCK-1, ZCK-1E, ZCK-1EG, ZCK-1EN and ZCK-50 Zonecheck Keyswitch for Control and Monitoring of the Zonecheck Flow Switch Tester Electrical Specifications OperatingVoltage: OperatingTemperature: OperatingHumidity: MountingOptions: OperationModes: LEDOperation: TestedtoEN61010-1 3825OhioAvenue,St.Charles,Illinois60174 1-800-SENSOR2,FAX:630-377-6495 www.systemsensor.com ZCK-1:120V,60Hz;ZCK-1E,ZCK-1EG,ZCK-1ENandZCK-50:220VAC,50Hz,3wMax. 0Cto49C(32Fto120F) 5%to95%RH(non-condensing) Includesbackboxforsurfaceorflushmounting. Forpre-wiring,usea411/16x411/16backbox Self-test:Wiredlocally Grouptest:Interconnected Readystate:NoLED Testinitiation:GreenLED Flowswitchactivation:RedLED(ZCK-1),GreenLED(ZCK-1E,ZCK-1EG,ZCK-1ENandZCK-50) WIRING DIAGRAM FOR STAND ALONE APPLICATION WARNING TO EARTH GND. Ifthisproductisnotusedasspecified,itmaybecomeimpaired. OR ATTACH TO JUNCTION BOX AC GROUND FOR INTERCONNECTING MULTIPLE ZONECHECK UNITS TO EARTH GND. OR ATTACH TO JUNCTION BOX GND AC AC PUMP INTERCONNECTING PUMP AC GROUND WIRING GND AC AC PUMP DIAGRAM PUMP AC POWER AC POWER FOR STAND ALONE APPLICATION TO EARTH GND. OR ATTACH TO JUNCTION BOX FOR MULTIPLE ZONECHECK UNIT TO EARTH GND. OR ATTACH TO JUNCTION BOX GND AC AC PUMP PUMP } } WF INPUT INTER-CONNECT AC GROUND GND AC AC WATERFLOW PUMP DETECTOR PUMP } } WF INPUT INTER-CONNECT AC GROUND AC POWER WATERFLOW DETECTOR AC POWE PUMP } } WF INPUT INTER-CONNECT PUMP } } WF INPUT INTER-CONNECT WATERFLOW DETECTOR TO EARTH GND. OR ATTACH TO JUNCTION BOX GND AC AC PUMP PUMP WATERFLOW DETECTOR AC GROUND PUMP PUMP AC POWER W0158-00 NOTE: WF input not required for keyswitch operation if waterflowdetectorisconnectedtopanelorothermonitoringdevice. ACpowerandpumpwiringmustconformtoNECoryour localcodes. } } WF INPUT INTER-CONNECT TO EARTH GND. OR ATTACH TO JUNCTION BOX GND AC AC WATERFLOW PUMP DETECTOR PUMP AC GROUND AC POWE PUMP TO NEXT ZONECHECK SWITCH FOR INTERCONNECT } } WF INPUT INTER-CONNECT W0158-00 WATERFLOW DETECTOR D770-31-00 1 PUMP I56-1610-007R ZCK-1E, ZCK-1EG, ZCK-1EN and ZCK-50 ZCK-1E, ZCK-1EG, ZCK-1EN and ZCK-50 If the pump used in this application is grounded, it must ToactivatetheZonecheckwiredlocallytothekeyswitchinsharethesameinput/outputearthgroundasthedevice. sertkeyandturntotheright.GreenLEDswillilluminatewhen eitherthepumporthewaterflowdetectorareactivated. Anovercurrentprotectiondevicesuchasaswitchorcircuit breakerisrequired.Theprotectiondevicemustbeclearly NOTE:TheLEDforthewaterflowdetectorwillnotillumimarkedandhaveamaximumratingof16A. nateifthedetectorisnotwiredtothekeyswitch.When testing has been completed, turn the key back to the Therearenoventilationrequirements. standbyposition. Pre-operation Guidelines Zonecheck Testing: Group-Test Mode Contactcentralmonitoringstationorappropriatefiresafety All Zonecheck systems whose key switches are interconpersonnelpriortotestingZonecheck. nected (refer to interconnecting wiring diagram), may be activated from any key switch. To initiate the group test, WARNING insertkeyandturntotheleft. Only activate the Zonecheck key switch when the valves TheLEDsonthekeyswitchusedtoinitiatethegrouptest areopenedandthesprinklersystemisfull. indicatetheactivityfortheZonecheckunitandwaterflow detectorconnectedtothatkeyswitchonly. Zonecheck Testing: Self-Test Mode ZCK-1 ToactivatetheZonecheckwiredlocallytothekeyswitchinsertkeyandturntotheright.ThegreenLEDwillilluminate toshowthatthepumphasbeenactivated.TheredLEDwill illuminateoncethewaterflowdetectorhasbeenactivated. NOTE: The red LED will not illuminate if the waterflow detectorisnotwiredtothekeyswitch.Whentestinghas beencompleted,turnthekeybacktothestandbyposition. Whentestinghasbeencompleted,turnthekeybacktothe standbyposition. Please refer to insert for the Limitations of Fire Alarm Systems Three-Year Limited Warranty SystemSensorwarrantsitsenclosedproducttobefreefromdefectsinmaterialsandworkmanshipundernormaluseandserviceforaperiodofthreeyears from date of manufacture. System Sensor makes no other express warranty fortheenclosedproduct.Noagent,representative,dealer,oremployeeofthe Companyhastheauthoritytoincreaseoraltertheobligationsorlimitations ofthisWarranty.TheCompany'sobligationofthisWarrantyshallbelimited tothereplacementofanypartoftheproductwhichisfoundtobedefective in materials or workmanship under normal use and service during the three yearperiodcommencingwiththedateofmanufacture.AfterphoningSystem Sensor'stollfreenumber800-SENSOR2(736-7672)foraReturnAuthorization number, send defective units postage prepaid to: System Sensor, Returns Department,RA#__________,3825OhioAvenue,St.Charles,IL60174.Please include a note describing the malfunction and suspected cause of failure. TheCompanyshallnotbeobligatedtoreplaceunitswhicharefoundtobe defectivebecauseofdamage,unreasonableuse,modifications,oralterations occurring after the date of manufacture. In no case shall the Company be liable for any consequential or incidental damages for breach of this or any otherWarranty,expressedorimpliedwhatsoever,evenifthelossordamage iscausedbytheCompany'snegligenceorfault.Somestatesdonotallowthe exclusionorlimitationofincidentalorconsequentialdamages,sotheabove limitationorexclusionmaynotapplytoyou.ThisWarrantygivesyouspecific legalrights,andyoumayalsohaveotherrightswhichvaryfromstatetostate. D770-31-00 2 I56-1610-007R (c)2005SystemSensor |
Price & Availability of ZCK-50
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |