BCD Series Optical blood component detectors FEATURES * Non-invasive optical technology * Micro-controller based integral circuitry * Immunity to ambient light * High accuracy and reliability * Detects blood per ANSI/AAMI RD5:2003 SPECIFICATIONS Maximum ratings Supply voltage (VS) Supply current Temperature limits Storage Operating Humidity limits 5 VDC (optional 6...24 VDC) typ. 150 mA ELECTRICAL CONNECTION -20 ... 85 C 5 ... 60 C 0 - 95 %RH (non-condensing) Sensor 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Brown Red Orange Yellow Green Blue Violet Gray White Return Power in CAL input CAL output Blood output Tube detect output Liquid detect output NC NC NC Red intensity analog output Blue intensity analog output NC NC Note: Set CAL input (Pin 3) momentary high to begin calibration. CAL output (Pin 4) will be high if calibration is complete. November 2007 / 307 1/3 www.sensortechnics.com BCD Series Optical blood component detectors PERFORMANCE CHARACTERISTICS Characteristics Logic low voltage Logic high voltage CAL input min. width1 Response time Calibration2 Blood detect3 Tube detect Liquid detect 100 200 VS-0.7 50 15 500 ms Min. Typ. Max. 0.6 Units V ms s Notes: 1. The minimum width for the CAL input to initiate a calibration cycle. Pulses shorter than this may be ignored 2. The maximum time to perform the tube calibration cycle. 3. The maximum time to detect blood levels rising above the limit or blood levels falling below the limit. OUTLINE DRAWING 0.42 (10.67) Slot for 0.250 (6.35) tube 1.25 (31.75) 1.50 (38.10) 0.75 (19.05) Threaded holes 4-40 x 0.22 (5.59) 1.25 (31.75) 1.00 (25.40) Connector Molex 51021-1400 all dimensions in inches (mm) November 2007 / 307 2/3 www.sensortechnics.com BCD Series Optical blood component detectors ORDERING INFORMATION Series Options BCD Electrical 1 5 V input, logic output 2 3 6...24 V input, logic output 5 V input, analog and logic output 6...24 V input, analog and logic output Options 000 Standard (threshold AAMI), 28 inch leads, no tube detection, no liquid detection 8 9 Design type for rigid tubing for soft tubing Tubing siz e 04 1/4 inch O.D. 4 Example: BCD - 1 000 - 8 04 Notes: Sensortechnics is asking customers for a sample of their tubing. The sensor will then be calibrated for exactly this tubing. For proper function the sensor should only be used with the tubing which was sent to Sensortechnics! Custom specific modifications are widely available. Please contact your nearest Sensortechnics sales office for further information. Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. November 2007 / 307 3/3 www.sensortechnics.com |
Price & Availability of BCD-4000-804
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |