 S/MOD/SLD03205/D/16/04/2003
Relais Statique miniature sortie DC DC SLIM Solid State Relay
* Compatibilite du brochage avec les Relais Electro-mecaniques . * Commande 5 , 12, 24 et 48 VDC selon modeles * Sortie 24VDC - 4A ( voir derating en temperature) * Ecreteur de surtension integre.
page 1 / 3 F/GB
SLD0x205
DC input 24VDC 4A output
* Pin to pin compatible with Electromechanic Relays. * 5 ; 12; 24 and 48VDC control * 24VDC - 4A output ( see derating curve) * Integrated clamping voltage.
28 (1.10) 5 (0.20)
grid 0,1"/ grille 2,54mm top view/vue de dessus
15 (0.59)
3,5 (0.14)
A2 1,4 (0.06)
A1 +
+
2 - o 0,8 mm 2 - o 1,1mm 0.15 0.65 0.20
3,8 (0.15) 0,5 x 0,4mm (0.02 x 0.015)
16,5 (0.65) Vue de dessous Bottom View
5,1 (0.20)
2 (0.08)
1 x 0,4mm (0.04 x 0.015)
PCB Layout
(-)
4 3 (+) INPUT
(+) 2
1 (-) OUTPUT
Caracteristiques de commande (a 20C) / Control characteristics (at 20C) Parameter Tension de commande / Control voltage Courant de commande / Control current (@ Uc nom ) Tension de relachement/Release voltage Resistance interne / Input internal resistor
SLD01205 SLD02205 SLD03205 SLD04205
DC DC DC DC Symbol Min Nom Max Min Nom Max Min Nom Max Min Nom Max Unit Uc 3 5 10 7 12 20 18 24 32 38 48 58 V Ic Uc off Rc 5,5 12 320 27 1,8 1070 5,5 10 18 3,6 3000 5,5 7,7 10,2 8,3 10800 3,5 4,4 5,3 8,3 mA V
Caracteristiques generales / General characteristics Parameter Plage de temperature de fonctionnement /Operating temperature range Plage de temperature de stockage /Storage temperature range Isolement entree-sortie / Input-output isolation Poids/Weight Temperature de soudage max / Maximum soldering heat(1 mm boitier/case) Conformite / Conformity Homologation / Approved Conditions Boitier / Case Boitier / Case Symbol Tc max Tc max Typ. -20 / +80 C -25 / +80 C 2500 VRMS 8 g Ts max 220 C IEC60947-5-1 & IEC60947-1 UL pending
10 s
Proud to serve you
All technical characteristics are subject to change without previous notice. Caracteristiques sujettes a modifications sans preavis.
celduc
r e l a i
s
S/MOD/SLD03205/D/16/04/2003
page 2 / 3 F/GB
Caracteristiques de sortie(a 20C) / Output characteristics (at 20C) Parameter Tension de charge / Load voltage Plage tension de fonctionnement / Operating range Courant nominal DC12/ DC-12 nominal current (Resistive loads...) Courant nominal DC13/ DC13 nominal current (Electromagnets) Courant nominal DC6/ DC-6 nominal current (Lamps) Courant de surcharge non repetitif /Non repetitive overload current Chute tension directe crete/ On state voltage drop Resistance de sortie a l'etat on / Static output on-resistance Courant de fuite etat bloque/ Off state leakage current Courant de charge minimum / Minimum load current Temps de fermeture/ Turn on time Temps d'ouverture/ Turn off time Frequence max de commutation / Operating switching frequency Transil de protection contre les surtension/Transient voltage suppressor -Tension d'ecretage/ Breakdown voltage -Puissance maximum / Peak power dissipation -Tension crete (ecreteur de tension) / Peak voltage (clamping voltage) EMC Test d'immunite conduite/Conducted immunity level EMC Test d'immunite conduite/Conducted immunity level Symbol Typ. Unit Ul 24 V Ulmin-max 0-32 V ( see Fig. 2 ) Il DC-12 4 A ( see Fig. 2 ) Il DC-13 4 A ( see Fig. 2 &3) Il DC-6 4 A tp=1s (Fig. 3) Il pulse 9A A @ Il nom, Vd 0,24V @ 2A V Uc nom , Il=2A R on max 120 m @Ul=24V Ilk max <1 mA Ilmin 1 mA Uc nom DC ton max 50 s Uc nom DC toff max 600 s Uc nom DC fs 100(*) Hz oui/ yes @1mA Ubr min 36 V Pulse 10/1000s Pr 600 W Up max 60 V IEC 1000-4-4 (bursts) 1kV criterion A /4kV criterion B IEC 1000-4-5 (shocks) Control :0,5kV crit. A Output 1kV crit. A Conditions
(*) : Frequence de commutation : A des frequences elevees, les pertes en commutation peuvent entrainer un echauffement du relais plus important. Il faut donc limiter un peu le courant. A faible courant, les limites en frequence correspondent aux temps de commutation et la frequence de commutation peut etre beaucoup plus importante. (*) : Operating frequency : With high frequency operating, turn ON and turn OFF commutation can increase the temperature of the SSR. So, with high frequency operating, it is necessary to limit a little bit the current. With low current, the frequency limit is given by the turn ON and turn OFF time, that means high frequency operating is possible.
Fig. 2 : Courant en fonction de la temperature ambiante / Load current vs. ambient temperature characteristics
5,5 5 4,5
Fig. 3 : Courant de surcharge non repetitif / Non repetitive surge current
Surge current Itsm (Apeak) = f(t) 50 Itsm (Apeak) 40 30 20 10 0 0,001
4 3,5
I (A)
3 2,5 2 1,5 1 0,5 0 0 10 20 30 40 50 60 70 80 Tambient(C)
0,01
0,1 t(s)
1
10
Precautions : * Dans le cas de plusieurs modules cote a cote, prevoir un derating en courant. * Sur charges inductives prevoir une diode de roue libre (ou ecreteur de surtension ). Voir page 3.
Cautions : * In case of many SSRs side by side , take a derating current in to account . * On inductive loads put a free-wheeling diode (or clamp ). See page 3.
celduc
r e l a i s
www.celduc.com
Rue Ampere B.P. 4 42290 SORBIERS - FRANCE E-Mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tel. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tel. +33 (0) 4 77 53 90 19
S/MOD/SLD03205/D/16/04/2003
page 3 / 3 F/GB
Fonctionnement sur charge Inductive Application on Inductive load Application type : Typical application : a) Utilisation d'une diode de roue libre (DRL) Using Free wheel diode (DRL).
+24VDC
Electovanne / Valve Une diode de roue libre sur la charge protege correctement le relais mais augmente le temps d'ouverture de la charge. DRL A free wheel diode protect the relay, but the turn OFF time increases.
SLD
0VDC
b) Utilisation de la protection interne au relais (Dz) Using internal voltage protection of the relay ( Dz)
+24VDC
SLD
Dz
La diode de protection interne au relais (Dz) peut etre utilisee dans la limite de sa puissance dissipee, ce qui limite la frequence de commutation : F max = 0,6/LI2 ( L= inductance de la charge ; I = courant de charge) The internal voltage protection (Dz)of the relay can be used but the switching frequency must be adapted to the max power dissipation of the internal protection : F max = 0,6/LI2 ( L= inductance of the load ; I = load current)
0VDC
c) Utilisation de protection transils ou VDR sur la charge : utiliser relais de tension superieure : voir fiche technique SLD0x210 Using transils or VDR protection on the load : use a higher voltage relay : see SLD0x210 data-sheet
+24VDC
SLD
0VDC
celduc
r e l a i s
www.celduc.com
Rue Ampere B.P. 4 42290 SORBIERS - FRANCE E-Mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tel. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tel. +33 (0) 4 77 53 90 19


▲Up To Search▲   

 
Price & Availability of SLD04205

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X