  Datasheet File OCR Text:
 Green Power Solutions srl
Via Greto di Cornigliano 6R - 16152 Genova , Italy
Phone: +39-010-659 1869 Fax: +39-010-659 1870 Web: www.gpsemi.it E-mail: info@gpsemi.it
GC118...F
BAR CLAMP FOR HOCKEY PUK DEVICES
Clamping total thikness of assembly from 21mm to 125mm Pre-loaded to the specific clamping force (22 / 32 kN) Maximum device diameter: 105mm Surface passivation to provide extra protection Hexagon head bolt partially threaded M8x1.25, UNI5737, 8.8 steel Various lengths of bolts and insulators Flat clamping head for optimal clamping force application Four styles available User friendly clamping force indicator UL94 certified insulation material
Parameter
Unit g
Types GC118S...F GC118B...F GC118...22F GC118...24F GC118...30F GC118...32F
Testing conditions
Notes Min 930 1750
Values Typ Max 1030 1870 22 24 30 32 10%
Weight
Clamping Force*
kN
Clamping Force tolerance Insulation Voltage VRMS 1 min Noryl E121562 C mm mm C mm UL94 V-1 Flame class rating UL94 V-0 Flame class rating CSA Flammability mm mm * Other clamping forces available: contact factory
** Noryl is a registered trade mark of General Electric
3000
Insulating Material
UL File Max. working temperature Creepage distance: Clearance distance: Storage temperature
-30 28 20.3 -40 1.5 8.00 1.00
110
110
Flammability
Document GC118...FT001
BAR CLAMP FOR HOCKEY PUK DEVICES
GC118...F
ORDERING INFORMATION TABLE
Clamps can be ordered using the following part numbering system
GC118
B
(1)
N
(2)
B
(3)
A
(4)
24
(5)
F
S
(6)
(1) Construction type: (2) Insulator position: (3) Insulator code: (4) Bolt code: (5) Clamping force (in kN):
B = with double bar S = with single bar N = upper side R = lower side see table below 22 24 30 32
K
see table below
K
(6) Special accessories
blank = no accessories S = extra bar spacer K: Total thickness of the assembly to be clamped
For thicknesses S' Min < K < S Min an additional 4mm thick bar spacer is needed (see list of special accessories)
Type GC118BN...F: suggested insulator/bolt types Allowed clearance S
S' Min [mm]** 21 31 41 51 61 71 81 S Min [mm] 25 35 45 55 65 75 85 S Max [mm] 40 50 60 70 80 90 100 (3) A B B C C C D Insulator choice Ins. Length [mm] 50 70 70 95 95 95 120 (4) Z A B C D E F Bolt choice Bolt Length [mm] 100 110 120 130 140 150 160 Max height T [mm] 117 127 137 147 157 167 177
** with additional metal spacer only
Type GC118BR...F: suggested insulator/bolt types Allowed clearance S Insulator choice
S' Min [mm]** 21 31 41 51 61 71 81 S Min [mm] 25 35 45 55 65 75 85 S Max [mm] 40 50 60 70 80 90 100 (3) A A A B B C C Ins. Length [mm] 50 *** 50 50 70 70 95 95 *** For S Max (4) Z A B C D E F
Bolt choice Bolt Length [mm] 100 110 120 130 140 150 160
Max height T [mm] 129 139 149 159 169 179 189
** with additional metal spacer only
Type GC118SN...F: suggested insulator/bolt types Allowed clearance S Insulator choice
S' Min [mm]** 21 31 41 51 61 71 81 S Min [mm] 25 35 45 55 65 75 85 S Max [mm] 40 50 60 70 80 90 100 (3) A B B C C C D Ins. Length [mm] 50 70 70 95 95 95 120 (4) Z A B C D E F
Bolt choice Bolt Length [mm] 100 110 120 130 140 150 160
Max height T [mm] 110 120 130 140 150 160 170
** with additional metal spacer only
Type GC118SR...F: suggested insulator/bolt types Allowed clearance S Insulator choice
S' Min [mm]** 46 56 66 76 86 96 106 S Min [mm] 50 60 70 80 90 100 110 S Max [mm] 65 75 85 95 105 115 125 (3) B B B C C D D Ins. Length [mm] 70 70 70 95 95 120 120 (4) Z A B C D E F
Bolt choice Bolt Length [mm] 100 110 120 130 140 150 160
Max height T [mm] 129 139 149 159 169 179 189
** with additional metal spacer only Document GC118...FT001
BAR CLAMP FOR HOCKEY PUK DEVICES
GC118...F
BAR CLAMP OUTLINES
143 143
39 22.5
67
T
22.5
106
O12
S
O12
106
118
25
118
GC118BN...F
143
25
GC118BR...F
143
22.5
25 14
O12
50 UP TO 120
106
22.5
S
106 O12 118
118
GC118SN...F
Document GC118...FT001
22
GC118SR...F
Dimensions in mm - Tolerances according to ISO 2768 MK
T
BAR CLAMP FOR HOCKEY PUK DEVICES
GC118...F
PRESSURE DISC
S Min
SPECIAL ACCESSORIES The following special accessories are available on request (see ordering information table) Bar spacer
145
S Max
OPTIONAL BAR SPACER
S' Min
O13
Dimensions in mm - Tolerances according to ISO 2768 MK
In the interest of product improvement Green Power Solutions reserves the right to change any specification given in this data sheet without
notice. Document GC118...FT001
4
25


▲Up To Search▲   

 
Price & Availability of GC11822F

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X