 1200W Single Output With Parallel Function
Features :
SCN-1K2
series
AC input 200~260V only Protections: Short circuit / Overload / Over voltage / Over temp. High reliability/ Low ripple noise Built-in remote sense function Built-in remote ON-OFF control Built-in parallel operation function Can adjust from 20~100% output voltage by external control 1-5V Forced air cooling by built-in DC fan Case coating with paint 2 years warranty
SPECIFICATION
ORDER NO. SAFETY MODEL NO. DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE SCN-1K2-05 1K2S-N005 5V 180A 0 ~ 180A 900W SCN-1K2-12 1K2S-N012 12V 100A 0 ~ 100A 1200W 120mVp-p SCN-1K2-15 1K2S-N015 15V 80A 0 ~ 80A 1200W 150mVp-p SCN-1K2-24 1K2S-N024 24V 50A 0 ~ 50A 1200W 240mVp-p SCN-1K2-48 1K2S-N048 48V 24A 0 ~ 24A 1152W 480mVp-p 1.0% 0.5% 0.5%
RIPPLE & NOISE (max.) Note.2 100mVp-p
5.0% typical adjustment by potentiometer 1.0% VOLTAGE TOLERANCE Note.3 2.5% LINE REGULATION LOAD REGULATION VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT (max.) LEAKAGE CURRENT (max.) OVERLOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC
(Note. 4)
20 ~ 100% adjustment by 1 ~ 5VDC external control 1.0% 1.0% 0.5% 0.5% 0.5% 0.5%
0.5% 2.0%
0.5% 0.5%
SETUP, RISE, HOLD UP TIME 800ms, 50ms, 16ms at full load 200 ~ 260VAC 290 ~ 370VDC 47 ~ 63Hz 77% 11A / 230VAC 120A / 230VAC 3.5mA / 240VAC 101 ~ 115% 110 ~ 135% rated output power Protection type : Current limiting, delay shut down o/p voltage, re-power on to recover 110 ~ 135% follow to output set up point Protection type : Shut down o/p voltage, re-power on to recover >100 / measure by heat sink, near transformer Protection type : Shut down o/p voltage, re-power on to recover -10 ~ +65 (Refer to output load derating curve) 20% ~ 90% RH non-condensing -20 ~ +85 0.04% / , 10 ~ 95% RH (0 ~ 50 ) 83% 85% 85% 87%
10 ~ 200Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, CSA22.2, IEC60950 approved I/P-O/P, I/P-FG :1500VAC I/P-O/P, I/P-FG, >100M Ohms / 500VDC / 25
ISOLATION RESISTANCE
/ 70% RH
EMI CONDUCTION & RADIATION Compliance to FCC part 15 class A ---HARMONIC CURRENT EMS IMMUNITY MTBF ---60Khrs min. MIL-HDBK-217F (25 )
OTHERS
DIMENSION PACKING SPECIAL FUNCTION
291*132*132mm (L*W*H) 4.75kg ; 4pcs/20kg/CARTON DC voltage adj., Remote sensing, remote control, parallel operation (refer to terminal instruction manual)
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. 2.Tolerence: includes set up tolerance, line regulation, load regulation. 3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
File Name:SCN-1K2-SPEC 2008-05-06
1200W Single Output With Parallel Function
Mechanical Specification
SCN-1K2
series
Unit:mm
291 200 199.5 L N FG AC INPUT
50.5 41
14.5
#6-32-4 M3(NUT).x3H-4
30
132
15
POS+
9
291 250 M3(NUT)x3H-4 Air flow direction
32
DC OUTPUT
POS
9.5
AC INPUT
BUTTON SIDE
M6
NEG
Terminal Pin No. Assignment
Pin No. 1 2 3 Assignment AC/L AC/N FG
Control terminal Pin No. Assignment (CN1) : Dinkle 51HDBC-O8P or equivalent
Pin No. 1 2 3 4 Assignment VS+ VSVCI VCO Pin No. 5 6 7 8 Assignment Mating With GND PAR Dinkle 51SDB-O8P or equivalent GND INH
Derating Curve
External DC Control VS Output Voltage
Vout
7.5
115
132
O.V.P.
100
100
OUTPUT VOLTAGE (%)
80
non-linear
LOAD (%)
60 40
50
20
-10
0
10
20
30
40
50
60
V 1 2 3 4 5
Ta (
)
EXTERNAL VOLTAGE(Typical)
File Name:SCN-1K2-SPEC 2008-05-06
VS+ VSVCI VCD GND PAR GND INH
LED NEGV ADJ
1200W Single Output With Parallel Function
Control terminal instruction manual
SCN-1K2
series
LOAD
LOAD
LOAD
VS+ VSVCI VCO GND PAR GND INH
VS+ VSVCI VCO GND PAR GND INH
VS+ VSVCI VCO GND PAR GND INH
ON/OFF SWITCH
USING INTERNAL VOLTAGE CONTROL
REMOTE SENSING
ON/OFF CONTROL BY SWITCH
LOAD
LOAD
VS+ VSVCI VCO GND PAR GND INH
H:ON L:OFF
VS+ VSVCI VCO GND PAR GND INH
DC 1-5V
ON/OFF CONTROL BY TRANSISTOR
OUTPUT VOLTAGE ADJUST WITH DC 1-5V
LOAD
LOAD
VS+ VSVCI VCO GND PAR GND INH
VS+ VSVCI VCO GND PAR GND INH
VS+ VSVCI VCO GND PAR GND INH
VS+ VSVCI VCO GND PAR GND INH
VS+ VSVCI VCO GND PAR GND INH
VS+ VSVCI VCO GND PAR GND INH
PARALLEL OPERATION WITH REMOTE SENSING
PARALLEL OPERATION
File Name:SCN-1K2-SPEC 2008-05-06