|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
M25PE20 M25PE10 1 and 2 Mbit, page-erasable serial Flash memories with byte alterability, 75 MHz SPI bus, standard pinout Features 1 or 2 Mbit of page-erasable Flash memory 2.7 V to 3.6 V single supply voltage SPI bus compatible serial interface 75 MHz clock rate (maximum) Page size: 256 bytes - Page Write in 11 ms (typical) - Page Program in 0.8 ms (typical) - Page Erase in 10 ms (typical) SubSector Erase (32 Kbits) Sector Erase (512 Kbits) Bulk Erase (1 Mbit for M25PE10, 2 Mbits for M25PE20) Deep Power-down mode 1 A (typical) Electronic signature - JEDEC standard two-byte signature (8012h for M25PE20, 8011h for M25PE10) - Unique ID code (UID) with 16 bytes readonly, available upon customer request only in the T9HX process Software write protection on a 64-Kbyte sector basis More than 100 000 Write cycles More than 20 years data retention Hardware write protection of the memory area selected using the BP0 and BP1 bits Package - ECOPACK(R) (RoHS compliant) VFQFPN8 (MP) 6 x 5 mm SO8N (MN) 150 mil width March 2008 Rev 5 1/64 www.numonyx.com 1 Contents M25PE20, M25PE10 Contents 1 2 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Signal descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 Serial Data output (Q) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Serial Data input (D) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Serial Clock (C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Chip Select (S) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Reset (Reset) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Top Sector Lock (TSL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Write Protect (W) or Top Sector Lock (TSL) . . . . . . . . . . . . . . . . . . . . . . . . 9 VCC supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 VSS ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 3 4 SPI modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Operating features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 Sharing the overhead of modifying data . . . . . . . . . . . . . . . . . . . . . . . . . . 12 An easy way to modify data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 A fast way to modify data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Polling during a Write, Program or Erase cycle . . . . . . . . . . . . . . . . . . . . 13 Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Active Power, Standby Power and Deep Power-down modes . . . . . . . . . 13 Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Protection modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 4.8.1 4.8.2 Protocol-related protections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Specific hardware and software protections . . . . . . . . . . . . . . . . . . . . . 15 5 6 Memory organization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 6.1 6.2 Write Enable (WREN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Write Disable (WRDI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 2/64 M25PE20, M25PE10 Contents 6.3 6.4 Read Identification (RDID) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Read Status Register (RDSR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 6.4.1 6.4.2 6.4.3 6.4.4 WIP bit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 WEL bit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 BP1, BP0 bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 SRWD bit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 6.5 6.6 6.7 6.8 6.9 6.10 6.11 6.12 6.13 6.14 6.15 6.16 6.17 Write Status Register (WRSR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Read Data Bytes (READ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Read Data Bytes at Higher Speed (FAST_READ) . . . . . . . . . . . . . . . . . . 32 Read Lock Register (RDLR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Page Write (PW) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Page Program (PP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Write to Lock Register (WRLR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Page Erase (PE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 SubSector Erase (SSE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Sector Erase (SE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Bulk Erase (BE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Deep Power-down (DP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Release from Deep Power-down (RDP) . . . . . . . . . . . . . . . . . . . . . . . . . . 44 7 8 9 10 11 12 13 14 Power-up and power-down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Initial delivery state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 DC and AC parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Package mechanical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Ordering information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 3/64 List of tables M25PE20, M25PE10 List of tables Table 1. Table 2. Table 3. Table 4. Table 5. Table 6. Table 7. Table 8. Table 9. Table 10. Table 11. Table 12. Table 13. Table 14. Table 15. Table 16. Table 17. Table 18. Table 19. Table 20. Table 21. Table 22. Table 23. Table 24. Table 25. Table 26. Table 27. Table 28. Table 29. Table 30. Signal names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Software protection truth table (sectors 0 to 3 for M25PE20 or sectors 0 to 1 for M25PE10, 64-Kbyte granularity) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Protected area sizes for M25PE20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Protected area sizes for M25PE10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 M25PE20 memory organization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 M25PE10 memory organization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Instruction set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Read Identification (RDID) data-out sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Status Register format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Protection modes (T9HX process only, see Important note on page 6) . . . . . . . . . . . . . . . 30 Lock Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Lock Register In . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Power-up timing and VWI threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Device status after a Reset Low pulse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Absolute maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Operating conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 AC measurement conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Capacitance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 DC characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 DC characteristics (T9HX (0.11 m) process) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 AC characteristics (25 MHz operation) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 AC characteristics (33 MHz operation) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 AC characteristics (50 MHz operation, T9HX (0.11 m) process) . . . . . . . . . . . . . . . . . . . 53 AC characteristics (75 MHz operation, T9HX (0.11 m) process) . . . . . . . . . . . . . . . . . . . 54 Reset conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Timings after a Reset Low pulse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 SO8N - 8 lead plastic small outline, 150 mils body width, package mechanical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 VFQFPN8 (MLP8), 8-lead very thin fine pitch quad flat package no lead, 6 x 5 mm, package mechanical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Ordering information scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 Document revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 4/64 M25PE20, M25PE10 List of figures List of figures Figure 1. Figure 2. Figure 3. Figure 4. Figure 5. Figure 6. Figure 7. Figure 8. Figure 9. Figure 10. Figure 11. Figure 12. Figure 13. Figure 14. Figure 15. Figure 16. Figure 17. Figure 18. Figure 19. Figure 20. Figure 21. Figure 22. Figure 23. Figure 24. Figure 25. Figure 26. Figure 27. Figure 28. Figure 29. Figure 30. Figure 31. Figure 32. Logic diagram - previous T7X process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Logic diagram - new T9HX process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 VFQFPN and SO connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Bus master and memory devices on the SPI bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 SPI modes supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 M25PE20 block diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 M25PE10 block diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Write Enable (WREN) instruction sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Write Disable (WRDI) instruction sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Read Identification (RDID) instruction sequence and data-out sequence . . . . . . . . . . . . . 26 Read Status Register (RDSR) instruction sequence and data-out sequence . . . . . . . . . . 28 Write Status Register (WRSR) instruction sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Read Data Bytes (READ) instruction sequence and data-out sequence . . . . . . . . . . . . . . 31 Read Data Bytes at Higher Speed (FAST_READ) instruction sequence and data-out sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Read Lock Register (RDLR) instruction sequence and data-out sequence . . . . . . . . . . . . 33 Page Write (PW) instruction sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Page Program (PP) instruction sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Write to Lock Register (WRLR) instruction sequence. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Page Erase (PE) instruction sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 SubSector Erase (SSE) instruction sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Sector Erase (SE) instruction sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Bulk Erase (BE) instruction sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Deep Power-down (DP) instruction sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Release from Deep Power-down (RDP) instruction sequence . . . . . . . . . . . . . . . . . . . . . . 44 Power-up timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 AC measurement I/O waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Serial input timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Top Sector Lock (T7X process) or Write Protect (T9HX process) setup and hold timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Output timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Reset AC waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 SO8N - 8 lead Plastic small outline, 150 mils body width, package outline . . . . . . . . . . . . 58 VFQFPN8 (MLP8), 8-lead very thin fine pitch quad flat package no lead, 6 x 5 mm, package outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 5/64 Description M25PE20, M25PE10 1 Description The M25PE20 and M25PE10 are 2 Mbit (256 Kb x 8 bit) and 1 Mbit (128 Kb x 8 bit) serial paged Flash memories, respectively. They are accessed by a high speed SPI-compatible bus. The memories can be written or programmed 1 to 256 bytes at a time, using the Page Write or Page Program instruction. The Page Write instruction consists of an integrated Page Erase cycle followed by a Page Program cycle. The M25PE20 memory is organized as 4 sectors, each containing 256 pages. Each page is 256 bytes wide. Thus, the whole memory can be viewed as consisting of 1024 pages, or 262,144 bytes. The M25PE10 memory is organized as 2 sectors, each containing 256 pages. Each page is 256 bytes wide. Thus, the whole memory can be viewed as consisting of 512 pages, or 131, 072 bytes. The memories can be erased a page at a time, using the Page Erase instruction, a subsector at a time, using the SubSector Erase instruction, a sector at a time, using the Sector Erase instruction or as a whole, using the Bulk Erase instruction. The memory can be write protected by either hardware or software using a mix of volatile and non-volatile protection features, depending on the application needs. The protection granularity is of 64 Kbytes (sector granularity). Important note This datasheet details the functionality of the M25PE20 and M25PE10 devices, based on the previous T7X process or based on the current T9HX process (available since July 2007). Delivery of parts operating with a maximum clock rate of 75 MHz starts from week 8 of 2008. What are the changes? The M25PE10/M25PE20 in T9HX process offers the following additional features: the whole memory array is partitioned into 4-Kbyte subsectors five new instructions: Write Status Register (WRSR), Write to Lock Register (WRLR), Read Lock Register (RDLR), 4-Kbyte SubSector Erase (SSE) and Bulk Erase (BE) Status Register: 3 bits can be written (BP0, BP1, SRWD) WP input (pin 3): write protection limits are extended, depending on the value of the BP0, BP1, SRWD bits. The WP write protection remains the same if bits (BP1, BP0) are set to (0, 1) or (1, 0) VFQFPN8 6 x 5 mm package added. 6/64 M25PE20, M25PE10 Description Figure 1. Logic diagram - previous T7X Figure 2. process VCC Logic diagram - new T9HX process VCC D C S TSL Reset M25PE20 M25PE10 Q D C S W Reset M25PE10 M25PE20 Q VSS AI09713 VSS AI13808 Table 1. Signal names Function Serial Clock Serial Data input Serial Data output Chip Select Top Sector Lock or Write Protect Reset Supply voltage Ground Input Input Output Input Input Input - - Direction Signal name C D Q S TSL or W(1) Reset VCC VSS 1. In the previous T7X process the pin is a Top Sector Lock input whereas in the new T9HX process, the pin is a Write Protect input (see Figure 1 and Figure 2). Figure 3. VFQFPN and SO connections M25PE20 M25PE10 S Q TSL or W VSS 1 2 3 4 8 7 6 5 VCC Reset C D AI09715b 1. There is an exposed central pad on the underside of the VFQFPN package. This is pulled, internally, to VSS, and must not be allowed to be connected to any other voltage or signal line on the PCB. 2. See Package mechanical section for package dimensions, and how to identify pin-1. 7/64 Signal descriptions M25PE20, M25PE10 2 2.1 Signal descriptions Serial Data output (Q) This output signal is used to transfer data serially out of the device. Data is shifted out on the falling edge of Serial Clock (C). 2.2 Serial Data input (D) This input signal is used to transfer data serially into the device. It receives instructions, addresses, and the data to be programmed. Values are latched on the rising edge of Serial Clock (C). 2.3 Serial Clock (C) This input signal provides the timing of the serial interface. Instructions, addresses, or data present at Serial Data input (D) are latched on the rising edge of Serial Clock (C). Data on Serial Data output (Q) changes after the falling edge of Serial Clock (C). 2.4 Chip Select (S) When this input signal is High, the device is deselected and Serial Data output (Q) is at high impedance. Unless an internal Read, Program, Erase or Write cycle is in progress, the device will be in the Standby Power mode (this is not the Deep Power-down mode). Driving Chip Select (S) Low selects the device, placing it in the Active Power mode. After power-up, a falling edge on Chip Select (S) is required prior to the start of any instruction. 2.5 Reset (Reset) The Reset (Reset) input provides a hardware reset for the memory. When Reset (Reset) is driven High, the memory is in the normal operating mode. When Reset (Reset) is driven Low, the memory will enter the Reset mode. In this mode, the output is high impedance. Driving Reset (Reset) Low while an internal operation is in progress will affect this operation (write, program or erase cycle) and data may be lost. 2.6 Top Sector Lock (TSL) This input signal puts the device in the Hardware Protected mode, when Top Sector Lock (TSL) is connected to VSS, causing the top 256 pages (upper addresses) of the memory to become read-only (protected from write, program and erase operations). When Top Sector Lock (TSL) is connected to VCC, the top 256 pages of memory behave like the other pages of memory. 8/64 M25PE20, M25PE10 Signal descriptions 2.7 Write Protect (W) or Top Sector Lock (TSL) The Write Protect function is available in the T9HX process only (see Important note on page 6) The Write Protect (W) input is used to freeze the size of the area of memory that is protected against write, program and erase instructions (as specified by the values in the BP1 and BP0 bits of the Status Register. See Section 6.4: Read Status Register (RDSR) for a description of these bits. The Top Sector Lock function is available in the T7X process only (see Important note on page 6) The input signal sets the device in the Hardware Protected mode, when Top Sector Lock (TSL) is connected to VSS, causing the top 256 pages (upper addresses) of the memory to become read-only (protected from write, program and erase operations). When Top Sector Lock (TSL) is connected to VCC, the top 256 pages of memory behave like the other pages of memory. 2.8 VCC supply voltage VCC is the supply voltage. 2.9 VSS ground VSS is the reference for the VCC supply voltage. 9/64 SPI modes M25PE20, M25PE10 3 SPI modes These devices can be driven by a microcontroller with its SPI peripheral running in either of the two following modes: CPOL=0, CPHA=0 CPOL=1, CPHA=1 For these two modes, input data is latched in on the rising edge of Serial Clock (C), and output data is available from the falling edge of Serial Clock (C). The difference between the two modes, as shown in Figure 5, is the clock polarity when the bus master is in Standby mode and not transferring data: C remains at 0 for (CPOL=0, CPHA=0) C remains at 1 for (CPOL=1, CPHA=1) Bus master and memory devices on the SPI bus VSS VCC R SDO SPI interface with (CPOL, CPHA) = (0, 0) or (1, 1) SDI SCK CQD SPI Bus Master R CS3 CS2 CS1 S W Reset or TSL S W Reset or TSL S Reset W or TSL SPI memory device VCC VSS R SPI memory device CQD VCC VSS R SPI memory device CQD VCC VSS Figure 4. AI13558b 1. The Write Protect or Top Sector Lock (W or TSL) signal should be driven, High or Low as appropriate. Figure 4 shows an example of three devices connected to an MCU, on an SPI bus. Only one device is selected at a time, so only one device drives the Serial Data output (Q) line at a time, the other devices are high impedance. Resistors R (represented in Figure 4) ensure that the M25PE20 or M25PE10 is not selected if the Bus Master leaves the S line in the high impedance state. As the Bus Master may enter a state where all inputs/outputs are in high impedance at the same time (for example, when the Bus Master is reset), the clock line (C) must be connected to an external pull-down resistor so that, when all inputs/outputs become high impedance, the S line is pulled High while the C line is pulled Low (thus ensuring that S and C do not become High at the same time, and so, that the tSHCH requirement is met). The typical value of R is 100 k assuming that the time constant R*Cp (Cp = parasitic , capacitance of the bus line) is shorter than the time during which the Bus Master leaves the SPI bus in high impedance. 10/64 M25PE20, M25PE10 SPI modes Example: Cp = 50 pF, that is R*Cp = 5 s <=> the application must ensure that the Bus Master never leaves the SPI bus in the high impedance state for a time period shorter than 5 s. Figure 5. CPOL CPHA C SPI modes supported 0 0 1 1 C D MSB Q MSB AI01438B 11/64 Operating features M25PE20, M25PE10 4 4.1 Operating features Sharing the overhead of modifying data To write or program one (or more) data bytes, two instructions are required: Write Enable (WREN), which is one byte, and a Page Write (PW) or Page Program (PP) sequence, which consists of four bytes plus data. This is followed by the internal cycle (of duration tPW or tPP). To share this overhead, the Page Write (PW) or Page Program (PP) instruction allows up to 256 bytes to be programmed (changing bits from 1 to 0) or written (changing bits to 0 or 1) at a time, provided that they lie in consecutive addresses on the same page of memory. 4.2 An easy way to modify data The Page Write (PW) instruction provides a convenient way of modifying data (up to 256 contiguous bytes at a time), and simply requires the start address, and the new data in the instruction sequence. The Page Write (PW) instruction is entered by driving Chip Select (S) Low, and then transmitting the instruction byte, three address bytes (A23-A0) and at least one data byte, and then driving Chip Select (S) High. While Chip Select (S) is being held Low, the data bytes are written to the data buffer, starting at the address given in the third address byte (A7-A0). When Chip Select (S) is driven High, the Write cycle starts. The remaining, unchanged, bytes of the data buffer are automatically loaded with the values of the corresponding bytes of the addressed memory page. The addressed memory page then automatically put into an Erase cycle. Finally, the addressed memory page is programmed with the contents of the data buffer. All of this buffer management is handled internally, and is transparent to the user. The user is given the facility of being able to alter the contents of the memory on a byte-by-byte basis. For optimized timings, it is recommended to use the Page Write (PW) instruction to write all consecutive targeted bytes in a single sequence versus using several Page Write (PW) sequences with each containing only a few bytes (see Page Write (PW), Table 23: AC characteristics (50 MHz operation, T9HX (0.11 m) process) and Table 24: AC characteristics (75 MHz operation, T9HX (0.11 m) process)). 12/64 M25PE20, M25PE10 Operating features 4.3 A fast way to modify data The Page Program (PP) instruction provides a fast way of modifying data (up to 256 contiguous bytes at a time), provided that it only involves resetting bits to 0 that had previously been set to 1. This might be: when the designer is programming the device for the first time when the designer knows that the page has already been erased by an earlier Page Erase (PE), SubSector Erase (SSE), Sector Erase (SE) or Bulk Erase (BE) instruction. This is useful, for example, when storing a fast stream of data, having first performed the erase cycle when time was available when the designer knows that the only changes involve resetting bits to `0' that are still set to `1'. When this method is possible, it has the additional advantage of minimizing the number of unnecessary erase operations, and the extra stress incurred by each page. For optimized timings, it is recommended to use the Page Program (PP) instruction to program all consecutive targeted bytes in a single sequence versus using several Page Program (PP) sequences with each containing only a few bytes (see Section 6.10: Page Program (PP), Table 23: AC characteristics (50 MHz operation, T9HX (0.11 m) process) and Table 24: AC characteristics (75 MHz operation, T9HX (0.11 m) process)). 4.4 Polling during a Write, Program or Erase cycle A further improvement in the write, program or erase time can be achieved by not waiting for the worst case delay (tPW, tPP, tPE, tBE, tW or tSE). The Write In Progress (WIP) bit is provided in the Status Register so that the application program can monitor its value, polling it to establish when the previous cycle is complete. 4.5 Reset An internal power-on Reset circuit helps protect against inadvertent data writes. Addition protection is provided by driving Reset (Reset) Low during the power-on process, and only driving it High when VCC has reached the correct voltage level, VCC(min). 4.6 Active Power, Standby Power and Deep Power-down modes When Chip Select (S) is Low, the device is selected, and in the Active Power mode. When Chip Select (S) is High, the device is deselected, but could remain in the Active Power mode until all internal cycles have completed (Program, Erase, Write). The device then goes in to the Standby Power mode. The device consumption drops to ICC1. The Deep Power-down mode is entered when the specific instruction (the Deep Powerdown (DP) instruction) is executed. The device consumption drops further to ICC2. The device remains in this mode until the Release from Deep Power-down instruction is executed. 13/64 Operating features M25PE20, M25PE10 All other instructions are ignored while the device is in the Deep Power-down mode. This can be used as an extra software protection mechanism, when the device is not in active use, to protect the device from inadvertent Write, Program or Erase instructions. 4.7 Status Register The Status Register contains two status bits that can be read by the Read Status Register (RDSR) instruction. See Section 6.4: Read Status Register (RDSR) for a detailed description of the Status Register bits. 4.8 Protection modes The environments where non-volatile memory devices are used can be very noisy. No SPI device can operate correctly in the presence of excessive noise. To help combat this, the M25PE10 and M25PE20 feature the following data protection mechanisms: 4.8.1 Protocol-related protections Power On Reset and an internal timer (tPUW) can provide protection against inadvertent changes while the power supply is outside the operating specification Program, Erase and Write instructions are checked that they consist of a number of clock pulses that is a multiple of eight, before they are accepted for execution All instructions that modify data must be preceded by a Write Enable (WREN) instruction to set the Write Enable Latch (WEL) bit. This bit is returned to its reset state by the following events: - - - - - - - - - - Power-up Reset (RESET) driven Low Write Disable (WRDI) instruction completion Page Write (PW) instruction completion Page Program (PP) instruction completion Write to Lock Register (WRLR) instruction completion Page Erase (PE) instruction completion SubSector Erase (SSE) instruction completion Sector Erase (SE) instruction completion Bulk Erase (BE) instruction completion The Reset (Reset) signal can be driven Low to freeze and reset the internal logic. For the specific cases of Program and Write cycles, the designer should refer to Section 6.5: Write Status Register (WRSR), Section 6.9: Page Write (PW), Section 6.10: Page Program (PP), Section 6.12: Page Erase (PE), Section 6.14: Sector Erase (SE), and Section 6.13: SubSector Erase (SSE), and to Table 14: Device status after a Reset Low pulse In addition to the low power consumption feature, the Deep Power-down mode offers extra software protection from inadvertent Write, Program and Erase instructions while the device is not in active use. 14/64 M25PE20, M25PE10 Operating features 4.8.2 Specific hardware and software protections The M25PE10/M25PE20 features a Hardware Protected mode, HPM, and two Software Protected modes, SPM1 and SPM2, that can be combined to protect the memory array as required. They are described below: HPM HPM in T7X process (see Important note on page 6): The Hardware Protected mode (HPM) is entered when Top Sector Lock (TSL) is driven Low, causing the top 256 pages of memory to become read-only. When Top Sector Lock (TSL) is driven High, the top 256 pages of memory behave like the other pages of memory and the protection depends on the Block Protect bits (see SPM2 below) HPM in T9HX process (see Important note on page 6): The Hardware Protected mode (HPM) is used to write-protect the non-volatile bits of the Status Register (that is, the Block Protect bits, BP1 and BP0, and the Status Register Write Disable bit, SRWD). HPM is entered by driving the Write Protect (W) signal Low with the SRWD bit set to High. This additional protection allows the Status Register to be hardware-protected. (see also Section 6.4.4: SRWD bit). SPM1 and SPM2 The first Software Protected mode (SPM1) is managed by specific Lock Registers assigned to each 64-Kbyte sector. The Lock Registers can be read and written using the Read Lock Register (RDLR) and Write to Lock Register (WRLR) instructions. In each Lock Register two bits control the protection of each sector: the Write Lock bit and the Lock Down bit. - Write Lock bit: The Write Lock bit determines whether the contents of the sector can be modified (using the Write, Program or Erase instructions). When the Write Lock bit is set to `1', the sector is write protected - any operations that attempt to change the data in the sector will fail. When the Write Lock bit is reset to `0', the sector is not writeprotected by the Lock Register, and may be modified - Lock Down bit: The Lock Down bit provides a mechanism for protecting software data from simple hacking and malicious attack. When the Lock Down bit is set to `1', further modification to the Write Lock and Lock Down bits cannot be performed. A reset, or power-up, is required before changes to these bits can be made. When the Lock Down bit is reset to `0', the Write Lock and Lock Down bits can be changed. The Write Lock bit and the Lock Down bit are volatile and their value is reset to `0' after a power-down or a reset. 15/64 Operating features Table 2. M25PE20, M25PE10 Software protection truth table (sectors 0 to 3 for M25PE20 or sectors 0 to 1 for M25PE10, 64-Kbyte granularity) Protection status Sector Lock Register Lock Down bit 0 0 1 1 Write Lock bit 0 1 0 1 Sector unprotected from program/erase/write operations, protection status reversible Sector protected from program/erase/write operations, protection status reversible Sector unprotected from program/erase/write operations, sector protection status cannot be changed except by a reset or power-up. Sector protected from program/erase/write operations, Sector protection status cannot be changed except by a reset or power-up. The second Software Protected mode (SPM2) uses the block protect (BP1, BP0, see Section 6.4.3)) bits to allow part of the memory to be configured as read-only. Protected area sizes for M25PE20 Memory content Protected area none Upper quarter (sector 3) Upper half (two sectors: 2 and 3) All sectors (four sectors: 0 to 3) Unprotected area All sectors(1) (four sectors: 0 to 3) Lower three quarters (three sectors: 0 to 2) Lower half (two sectors: 0 to 1) none Table 3. Status Register content BP1 bit BP0 bit 0 0 1 1 0 1 0 1 1. The device is ready to accept a Bulk Erase instruction if, and only if, all block protect bits (BP1, BP0) are 0. Table 4. Protected area sizes for M25PE10 Memory content Protected area none Upper half (1 sector: sector 1) Upper half (1 sector: sector 1) All sectors (two sectors: 0 and 1) Unprotected area All sectors(1) (two sectors: 0 and 1) Lower half (one sector: sector 0) Lower half (one sector: sector 0) none Status Register content BP1 bit BP0 bit 0 0 1 1 0 1 0 1 1. The device is ready to accept a Bulk Erase instruction if, and only if, all block protect bits (BP1, BP0) are 0. 16/64 M25PE20, M25PE10 Memory organization 5 Memory organization The M25PE20 memory is organized as: 1024 pages (256 bytes each). 262,144 bytes (8 bits each) 64 subsectors (32 Kbits, 4,096 bytes each) 4 sectors (512 Kbits, 65,536 bytes each) 512 pages (256 bytes each). 131,074 bytes (8 bits each) 32 subsectors (32 Kbits, 4,096 bytes each) 2 sectors (512 Kbits, 65,536 bytes each) programmed (bits are programmed from 1 to 0) erased (bits are erased from 0 to 1) written (bits are changed to either 0 or 1). The M25PE10 memory is organized as: In the M25PE20 and M25PE10, each page can be individually: The device is page or sector erasable (bits are erased from 0 to 1). Table 5. Sector M25PE20 memory organization Subsector 63 3 ... 3F000h ... Address range 3FFFFh ... 30FFFh 2FFFFh ... 20FFFh 1FFFFh ... 10FFFh 0FFFFh ... 04FFFh 03FFFh 02FFFh 01FFFh 00FFFh 48 47 2 ... 30000h 2F000h ... 20000h 1F000h ... 10000h 0F000h ... 04000h 03000h 02000h 01000h 00000h 32 31 1 ... 16 15 ... 4 0 3 2 1 0 17/64 Memory organization Table 6. Sector M25PE20, M25PE10 M25PE10 memory organization Subsector 31 1F000h ... Address range 1FFFFh ... 10FFFh 0FFFFh ... 04FFFh 03FFFh 02FFFh 01FFFh 00FFFh 1 16 15 ... ... 10000h 0F000h ... 04000h 03000h 02000h 01000h 00000h 4 0 3 2 1 0 18/64 M25PE20, M25PE10 Figure 6. Reset TSL or W S C D Q Control Logic High Voltage Generator Memory organization M25PE20 block diagram I/O Shift Register Address Register and Counter 256 byte Data Buffer Status Register 3FF00h 3FFFFh Top 256 pages can be made read-only by using the TSL pin(1) 2FFFFh Y Decoder The whole memory array can be made read-only on a 64-Kbyte basis through the Lock Registers 00000h 256 bytes (page size) X Decoder 000FFh AI3294b 1. These features (in gray) are only available in the T7X process. 19/64 Memory organization Figure 7. Reset TSL or W S C D Q Control Logic High Voltage Generator M25PE20, M25PE10 M25PE10 block diagram I/O Shift Register Address Register and Counter 256 byte Data Buffer Status Register 1FF00h 1FFFFh Top 256 pages can be made read-only by using the TSL pin(1) Y Decoder FFFFh The whole memory array can be made read-only on a 64-Kbyte basis through the Lock Registers 000FFh 256 bytes (page size) X Decoder 00000h AI13295b 1. These features (in gray) are only available in the T7X process. 20/64 M25PE20, M25PE10 Instructions 6 Instructions All instructions, addresses and data are shifted in and out of the device, most significant bit first. Serial Data input (D) is sampled on the first rising edge of Serial Clock (C) after Chip Select (S) is driven Low. Then, the one-byte instruction code must be shifted into the device, most significant bit first, on Serial Data input (D), each bit being latched on the rising edges of Serial Clock (C). The instruction set is listed in Table 7. Every instruction sequence starts with a one-byte instruction code. Depending on the instruction, this might be followed by address bytes, or by data bytes, or by both or none. In the case of a Read Data Bytes (READ), Read Data Bytes at Higher Speed (Fast_Read), Read Status Register (RDSR) or Read to Lock Register (RDLR) instruction, the shifted-in instruction sequence is followed by a data-out sequence. Chip Select (S) can be driven High after any bit of the data-out sequence is being shifted out. In the case of a Page Write (PW), Page Program (PP), Page Erase (PE), SubSector Erase (SSE), Sector Erase (SE), Bulk Erase (BE), Write Enable (WREN), Write Disable (WRDI), Write Status Register (WRSR), Write to Lock Register (WRLR), Deep Power-down (DP) or Release from Deep Power-down (RDP) instruction, Chip Select (S) must be driven High exactly at a byte boundary, otherwise the instruction is rejected, and is not executed. That is, Chip Select (S) must driven High when the number of clock pulses after Chip Select (S) being driven Low is an exact multiple of eight. All attempts to access the memory array during a Write cycle, Program cycle or Erase cycle are ignored, and the internal Write cycle, Program cycle or Erase cycle continues unaffected. 21/64 Instructions Table 7. Instruction WREN WRDI RDID RDSR(2) WRLR(2) WRSR(2) RDLR READ M25PE20, M25PE10 Instruction set Description Write Enable Write Disable Read Identification Read Status Register Write to Lock Register Write Status Register Read Lock Register Read Data Bytes One-byte instruction code 0000 0110 0000 0100 1001 1111 0000 0101 1110 0101 0000 0001 1110 1000 0000 0011 0000 1011 0000 1010 0000 0010 1101 1011 0010 0000 1101 1000 1100 0111 1011 1001 1010 1011 06h 04h 9Fh 05h E5h 01h E8h 03h 0Bh 0Ah 02h DBh 20h D8h C7h B9h ABh Addr Dummy bytes bytes 0 0 0 0 3 0 3 3 3 3 3 3 3 3 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 Data bytes 0 0 1 to 20(1) 1 to 1 1 1 1 to 1 to 1 to 256 1 to 256 0 0 0 0 0 0 FAST_READ Read Data Bytes at Higher Speed PW PP PE SSE(2) SE BE(2) DP RDP Page Write Page Program Page Erase SubSector Erase Sector Erase Bulk Erase Deep Power-down Release from Deep Power-down 1. The 17 bytes of Unique ID code are available only in the T9HX process (see Important note on page 6). 2. Instruction available only in the T9HX process (see Important note on page 6). 22/64 M25PE20, M25PE10 Instructions 6.1 Write Enable (WREN) The Write Enable (WREN) instruction (Figure 8) sets the Write Enable Latch (WEL) bit. The Write Enable Latch (WEL) bit must be set prior to every Page Write (PW), Page Program (PP), Page Erase (PE), and Sector Erase (SE) instruction. The Write Enable (WREN) instruction is entered by driving Chip Select (S) Low, sending the instruction code, and then driving Chip Select (S) High. Figure 8. Write Enable (WREN) instruction sequence S 0 C Instruction D High Impedance Q AI02281E 1 2 3 4 5 6 7 23/64 Instructions M25PE20, M25PE10 6.2 Write Disable (WRDI) The Write Disable (WRDI) instruction (Figure 9) resets the Write Enable Latch (WEL) bit. The Write Disable (WRDI) instruction is entered by driving Chip Select (S) Low, sending the instruction code, and then driving Chip Select (S) High. The Write Enable Latch (WEL) bit is reset under the following conditions: Power-up Write Disable (WRDI) instruction completion Page Write (PW) instruction completion Page Program (PP) instruction completion Write Status Register (WRSR) instruction completion Write to Lock Register (WRLR) instruction completion Page Erase (PE) instruction completion SubSector Erase (SSE) instruction completion Sector Erase (SE) instruction completion Bulk Erase (BE) instruction completion Write Disable (WRDI) instruction sequence S 0 C Instruction D High Impedance Q AI03750D Figure 9. 1 2 3 4 5 6 7 24/64 M25PE20, M25PE10 Instructions 6.3 Read Identification (RDID) The Read Identification (RDID) instruction allows to read the device identification data: Manufacturer identification (1 byte) Device identification (2 bytes) A Unique ID code (UID) (17 bytes, of which 16 available upon customer request)(a). The manufacturer identification is assigned by JEDEC, and has the value 20h for Numonyx. The device identification is assigned by the device manufacturer, and indicates the memory type in the first byte (80h), and the memory capacity of the device in the second byte (12h for the M25PE20 and 11h for the M25PE10). The UID contains the length of the following data in the first byte (set to 10h), and 16 bytes of the optional Customized Factory Data (CFD) content. The CFD bytes are read-only and can be programmed with customers data upon their demand. If the customers do not make requests, the devices are shipped with all the CFD bytes programmed to zero (00h). Any Read Identification (RDID) instruction while an Erase or Program cycle is in progress, is not decoded, and has no effect on the cycle that is in progress. The device is first selected by driving Chip Select (S) Low. Then, the 8-bit instruction code for the instruction is shifted in. After this, the 24-bit device identification, stored in the memory, the 8-bit CFD length followed by 16 bytes of CFD content will be shifted out on Serial Data output (Q). Each bit is shifted out during the falling edge of Serial Clock (C). The instruction sequence is shown in Figure 10. The Read Identification (RDID) instruction is terminated by driving Chip Select (S) High at any time during data output. When Chip Select (S) is driven High, the device is put in the Standby Power mode. Once in the Standby Power mode, the device waits to be selected, so that it can receive, decode and execute instructions. Table 8. Read Identification (RDID) data-out sequence Device identification Memory type 80h 80h Memory capacity 12h (M25PE20) 11h (M25PE10) CFD length 10h 10h UID(1) CFD content 16 bytes 16 bytes Manufacturer identification 20h 20h 1. The Unique ID code is available only in the T9HX process (see Important note on page 6). a. The 17 bytes of Unique ID code are available only in the T9HX process (see Important note on page 6). 25/64 Instructions M25PE20, M25PE10 Figure 10. Read Identification (RDID) instruction sequence and data-out sequence S 0 C Instruction D Manufacturer identification High Impedance Q MSB 15 14 13 MSB 3 2 1 0 MSB AI06809c 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 28 29 30 31 Device identification UID 1. The Unique ID code is available only in the T9HX process (see Important note on page 6). 26/64 M25PE20, M25PE10 Instructions 6.4 Read Status Register (RDSR) The Read Status Register (RDSR) instruction allows the Status Register to be read. The Status Register may be read at any time, even while a Program, Erase or Write cycle is in progress. When one of these cycles is in progress, it is recommended to check the Write In Progress (WIP) bit before sending a new instruction to the device. It is also possible to read the Status Register continuously, as shown in Figure 11. The status bits of the Status Register are as follows: 6.4.1 WIP bit The Write In Progress (WIP) bit indicates whether the memory is busy with a Write, Program or Erase cycle. When set to `1', such a cycle is in progress, when reset to `0' no such cycle is in progress. 6.4.2 WEL bit The Write Enable Latch (WEL) bit indicates the status of the internal Write Enable Latch. When set to `1' the internal Write Enable Latch is set, when set to `0' the internal Write Enable Latch is reset and no write, program or erase instruction is accepted. 6.4.3 BP1, BP0 bits The Block Protect (BP1, BP0) bits are non-volatile. They define the size of the area to be software protected against Program and Erase instructions. These bits are written with the Write Status Register (WRSR) instruction. When one or both of the Block Protect (BP1, BP0) bits is set to `1', the relevant memory area (as defined in Table 3) becomes protected against Page Program (PP), Page Erase (PE), Sector Erase (SE) and SubSector Erase (SSE) instructions. The Block Protect (BP1, BP0) bits can be written provided that the Hardware Protected mode has not been set. The Bulk Erase (BE) instruction is executed if, and only if: all Block Protect (BP1, BP0) bits are 0 the Lock Register protection bits are not all set to `1'. 6.4.4 SRWD bit The Status Register Write Disable (SRWD) bit is operated in conjunction with the Write Protect (W) signal. When the Status Register Write Disable (SRWD) bit is set to `1', and Write Protect (W) is driven Low, the non-volatile bits of the Status Register (SRWD, BP1, BP0) become read-only bits. In such a state, as the Write Status Register (WRSR) instruction is no longer accepted for execution, the definition of the size of the Write Protected area cannot be further modified. Table 9. b7 SRWD 0 0 0 BP1 BP0 WEL(3) Status Register format(1) (2) b0 WIP(3) 1. SRWD = Status Register Write Protect bit; BP0, BP1 = block protect bits (only available with T9HX). 2. The BP bits and the SRWD bit exist only in the T9HX process. 3. WEL (Write Enable Latch) and WIP (Write In Progress) are volatile read-only bits (WEL is set and reset by specific instructions; WIP is automatically set and reset by the internal logic of the device). 27/64 Instructions M25PE20, M25PE10 Figure 11. Read Status Register (RDSR) instruction sequence and data-out sequence S 0 C Instruction D Status Register Out High Impedance Q 7 MSB 6 5 4 3 2 1 0 7 MSB AI02031E 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Status Register Out 6 5 4 3 2 1 0 7 28/64 M25PE20, M25PE10 Instructions 6.5 Write Status Register (WRSR) The Write Status Register (WRSR) instruction allows new values to be written to the Status Register. Note: The Status Register BPi and SRWD bits are available in the T9HX process only. See Important note on page 6 for more details. Before the Write Status Register (WRSR) instruction can be accepted, a Write Enable (WREN) instruction must previously have been executed. After the Write Enable (WREN) instruction has been decoded and executed, the device sets the Write Enable Latch (WEL). The Write Status Register (WRSR) instruction is entered by driving Chip Select (S) Low, followed by the instruction code and the data byte on Serial Data input (D). The instruction sequence is shown in Figure 12. The Write Status Register (WRSR) instruction has no effect on b6, b5, b1 and b0 of the Status Register. b6 and b5 are always read as 0. Chip Select (S) must be driven High after the eighth bit of the data byte has been latched in. If not, the Write Status Register (WRSR) instruction is not executed. As soon as Chip Select (S) is driven High, the self-timed Write Status Register cycle (whose duration is tW) is initiated. While the Write Status Register cycle is in progress, the Status Register may still be read to check the value of the Write In Progress (WIP) bit. The Write In Progress (WIP) bit is 1 during the self-timed Write Status Register cycle, and is 0 when it is completed. When the cycle is completed, the Write Enable Latch (WEL) is reset. The Write Status Register (WRSR) instruction allows the user to change the values of the Block Protect (BP1, BP0) bits, to define the size of the area that is to be treated as readonly, as defined in Table 3. The Write Status Register (WRSR) instruction also allows the user to set or reset the Status Register Write Disable (SRWD) bit in accordance with the Write Protect (W) signal (see Section 6.4.4). If a Write Status Register (WRSR) instruction is interrupted by a Reset Low pulse, the internal cycle of the Write Status Register operation (whose duration is tW) is first completed (provided that the supply voltage VCC remains within the operating range). After that the device enters the Reset mode (see also Table 14: Device status after a Reset Low pulse and Table 26: Timings after a Reset Low pulse). Figure 12. Write Status Register (WRSR) instruction sequence S 0 C Instruction Status Register In 7 High Impedance Q AI02282D 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 D 6 5 4 3 2 1 0 MSB 29/64 Instructions Table 10. M25PE20, M25PE10 Protection modes (T9HX process only, see Important note on page 6) Mode Write protection of the Status Register Status Register is writable (if the WREN instruction has set the WEL bit) The values in the SRWD, BP1 and BP0 bits can be changed Memory content Protected area(1) Unprotected area(1) W SRWD signal bit 1 0 1 0 0 1 Second Software Protected (SPM2) Protected against Page Program, Sector Erase and Bulk Erase Ready to accept Page Program and Sector Erase instructions 0 1 Status Register is Hardware Hardware write protected Protected The values in the SRWD, (HPM) BP1 and BP0 bits cannot be changed Protected against Page Program, Sector Erase and Bulk Erase Ready to accept Page Program and Sector Erase instructions 1. As defined by the values in the Block Protect (BP1, BP0) bits of the Status Register, as shown in Table 3. The protection features of the device are summarized in Table 10. When the Status Register Write Disable (SRWD) bit of the Status Register is 0 (its initial delivery state), it is possible to write to the Status Register provided that the Write Enable Latch (WEL) bit has previously been set by a Write Enable (WREN) instruction, regardless of the whether Write Protect (W) is driven High or Low. When the Status Register Write Disable (SRWD) bit of the Status Register is set to `1', two cases need to be considered, depending on the state of Write Protect (W): If Write Protect (W) is driven High, it is possible to write to the Status Register provided that the Write Enable Latch (WEL) bit has previously been set by a Write Enable (WREN) instruction If Write Protect (W) is driven Low, it is not possible to write to the Status Register even if the Write Enable Latch (WEL) bit has previously been set by a Write Enable (WREN) instruction. Attempts to write to the Status Register are rejected, and are not accepted for execution. As a consequence, all the data bytes in the memory area that are software protected (SPM2) by the Block Protect (BP1, BP0) bits of the Status Register, are also hardware protected against data modification. Regardless of the order of the two events, the Hardware Protected Mode (HPM) can be entered: by setting the Status Register Write Disable (SRWD) bit after driving Write Protect (W) Low or by driving Write Protect (W) Low after setting the Status Register Write Disable (SRWD) bit. The only way to exit the Hardware Protected Mode (HPM) once entered is to pull Write Protect (W) High. If Write Protect (W) is permanently tied High, the Hardware Protected mode (HPM) can never be activated, and only the Software Protected mode (SPM2), using the Block Protect (BP1, BP0) bits of the Status Register, can be used. 30/64 M25PE20, M25PE10 Instructions 6.6 Read Data Bytes (READ) The device is first selected by driving Chip Select (S) Low. The instruction code for the Read Data Bytes (READ) instruction is followed by a 3-byte address (A23-A0), each bit being latched-in during the rising edge of Serial Clock (C). Then the memory contents, at that address, is shifted out on Serial Data output (Q), each bit being shifted out, at a maximum frequency fR, during the falling edge of Serial Clock (C). The instruction sequence is shown in Figure 13. The first byte addressed can be at any location. The address is automatically incremented to the next higher address after each byte of data is shifted out. The whole memory can, therefore, be read with a single Read Data Bytes (READ) instruction. When the highest address is reached, the address counter rolls over to 000000h, allowing the read sequence to be continued indefinitely. The Read Data Bytes (READ) instruction is terminated by driving Chip Select (S) High. Chip Select (S) can be driven High at any time during data output. Any Read Data Bytes (READ) instruction, while an Erase, Program or Write cycle is in progress, is rejected without having any effects on the cycle that is in progress. Figure 13. Read Data Bytes (READ) instruction sequence and data-out sequence S 0 C Instruction 24-Bit Address 1 2 3 4 5 6 7 8 9 10 28 29 30 31 32 33 34 35 36 37 38 39 D High Impedance Q 23 22 21 MSB 3 2 1 0 Data Out 1 7 6 5 4 3 2 1 0 Data Out 2 7 MSB AI03748D 1. Address bits A23 to A18 are `Don't care' in the M25PE20. Address bits A23 to A17 are `Don't care' in the M25PE10. 31/64 Instructions M25PE20, M25PE10 6.7 Read Data Bytes at Higher Speed (FAST_READ) The device is first selected by driving Chip Select (S) Low. The instruction code for the Read Data Bytes at Higher Speed (FAST_READ) instruction is followed by a 3-byte address (A23A0) and a dummy byte, each bit being latched-in during the rising edge of Serial Clock (C). Then the memory contents, at that address, is shifted out on Serial Data output (Q), each bit being shifted out, at a maximum frequency fC, during the falling edge of Serial Clock (C). The instruction sequence is shown in Figure 14. The first byte addressed can be at any location. The address is automatically incremented to the next higher address after each byte of data is shifted out. The whole memory can, therefore, be read with a single Read Data Bytes at Higher Speed (FAST_READ) instruction. When the highest address is reached, the address counter rolls over to 000000h, allowing the read sequence to be continued indefinitely. The Read Data Bytes at Higher Speed (FAST_READ) instruction is terminated by driving Chip Select (S) High. Chip Select (S) can be driven High at any time during data output. Any Read Data Bytes at Higher Speed (FAST_READ) instruction, while an Erase, Program or Write cycle is in progress, is rejected without having any effects on the cycle that is in progress. Figure 14. Read Data Bytes at Higher Speed (FAST_READ) instruction sequence and data-out sequence S 0 C Instruction 24-bit address 1 2 3 4 5 6 7 8 9 10 28 29 30 31 D High Impedance Q 23 22 21 3 2 1 0 S 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 C Dummy byte D 7 6 5 4 3 2 1 0 DATA OUT 1 DATA OUT 2 1 0 7 MSB 6 5 4 3 2 1 0 7 MSB AI04006 Q 7 MSB 6 5 4 3 2 1. Address bits A23 to A18 are `Don't care' in the M25PE20. Address bits A23 to A17 are `Don't care' in the M25PE10. 32/64 M25PE20, M25PE10 Instructions 6.8 Note: Read Lock Register (RDLR) The Read Lock Register (RDLR) instruction is decoded only in the T9HX process (see Important note on page 6). The device is first selected by driving Chip Select (S) Low. The instruction code for the Read Lock Register (RDLR) instruction is followed by a 3-byte address (A23-A0) pointing to any location inside the concerned sector (or subsector). Each address bit is latched-in during the rising edge of Serial Clock (C). Then the value of the Lock Register is shifted out on Serial Data output (Q), each bit being shifted out, at a maximum frequency fC, during the falling edge of Serial Clock (C). The instruction sequence is shown in Figure 15. The Read Lock Register (RDLR) instruction is terminated by driving Chip Select (S) High at any time during data output. Any Read Lock Register (RDLR) instruction, while an Erase, Program or Write cycle is in progress, is rejected without having any effects on the cycle that is in progress. Table 11. Bit b7-b4 `1' b1 Sector Lock Down `0' `1' b0 Sector Write Lock `0' Lock Registers Bit name Value Reserved The Write Lock and Lock Down bits cannot be changed. Once a `1' is written to the Lock Down bit it cannot be cleared to `0', except by a reset or power-up. The Write Lock and Lock Down bits can be changed by writing new values to them (default value). Write, program and erase operations in this sector will not be executed. The memory contents will not be changed. Write, program and erase operations in this sector are executed and will modify the sector contents (default value). Function Figure 15. Read Lock Register (RDLR) instruction sequence and data-out sequence S 0 C Instruction 24-bit address 1 2 3 4 5 6 7 8 9 10 28 29 30 31 32 33 34 35 36 37 38 39 D High Impedance Q 23 22 21 MSB 3 2 1 0 Lock Register Out 7 6 5 4 3 2 1 0 MSB AI10783 33/64 Instructions M25PE20, M25PE10 6.9 Page Write (PW) The Page Write (PW) instruction allows bytes to be written in the memory. Before it can be accepted, a Write Enable (WREN) instruction must previously have been executed. After the Write Enable (WREN) instruction has been decoded, the device sets the Write Enable Latch (WEL). The Page Write (PW) instruction is entered by driving Chip Select (S) Low, followed by the instruction code, three address bytes and at least one data byte on Serial Data input (D). The rest of the page remains unchanged if no power failure occurs during this write cycle. The Page Write (PW) instruction performs a page erase cycle even if only one byte is updated. If the 8 least significant address bits (A7-A0) are not all zero, all transmitted data exceeding the addressed page boundary roll over, and are written from the start address of the same page (the one whose 8 least significant address bits (A7-A0) are all zero). Chip Select (S) must be driven Low for the entire duration of the sequence. The instruction sequence is shown in Figure 16. If more than 256 bytes are sent to the device, previously latched data are discarded and the last 256 data bytes are guaranteed to be written correctly within the same page. If less than 256 data bytes are sent to device, they are correctly written at the requested addresses without having any effects on the other bytes of the same page. For optimized timings, it is recommended to use the Page Write (PW) instruction to write all consecutive targeted bytes in a single sequence versus using several Page Write (PW) sequences with each containing only a few bytes (see Table 23: AC characteristics (50 MHz operation, T9HX (0.11 m) process) and Table 24: AC characteristics (75 MHz operation, T9HX (0.11 m) process)). Chip Select (S) must be driven High after the eighth bit of the last data byte has been latched in, otherwise the Page Write (PW) instruction is not executed. As soon as Chip Select (S) is driven High, the self-timed Page Write cycle (whose duration is tPW) is initiated. While the Page Write cycle is in progress, the Status Register may be read to check the value of the Write In Progress (WIP) bit. The Write In Progress (WIP) bit is 1 during the self-timed Page Write cycle, and is 0 when it is completed. At some unspecified time before the cycle is complete, the Write Enable Latch (WEL) bit is reset. A Page Write (PW) instruction applied to a page that is Hardware Protected is not executed. Any Page Write (PW) instruction, while an Erase, Program or Write cycle is in progress, is rejected without having any effects on the cycle that is in progress. 34/64 M25PE20, M25PE10 Figure 16. Page Write (PW) instruction sequence S 0 C Instruction 24-bit address Data byte 1 1 2 3 4 5 6 7 8 9 10 Instructions 28 29 30 31 32 33 34 35 36 37 38 39 D 23 22 21 MSB 3 2 1 0 7 6 5 4 3 2 1 0 MSB S 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 C Data byte 2 Data byte 3 Data byte n D 7 6 5 4 3 2 1 0 7 MSB 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 MSB MSB AI04045 1. Address bits A23 to A18 are `Don't care' in the M25PE20. Address bits A23 to A17 are `Don't care' in the M25PE10. 2. 1 n 256. 35/64 Instructions M25PE20, M25PE10 6.10 Page Program (PP) The Page Program (PP) instruction allows bytes to be programmed in the memory (changing bits from 1 to 0, only). Before it can be accepted, a Write Enable (WREN) instruction must previously have been executed. After the Write Enable (WREN) instruction has been decoded, the device sets the Write Enable Latch (WEL). The Page Program (PP) instruction is entered by driving Chip Select (S) Low, followed by the instruction code, three address bytes and at least one data byte on Serial Data input (D). If the 8 least significant address bits (A7-A0) are not all zero, all transmitted data exceeding the addressed page boundary roll over, and are programmed from the start address of the same page (the one whose 8 least significant address bits (A7-A0) are all zero). Chip Select (S) must be driven Low for the entire duration of the sequence. The instruction sequence is shown in Figure 17. If more than 256 bytes are sent to the device, previously latched data are discarded and the last 256 data bytes are guaranteed to be programmed correctly within the same page. If less than 256 data bytes are sent to device, they are correctly programmed at the requested addresses without having any effects on the other bytes of the same page. For optimized timings, it is recommended to use the Page Program (PP) instruction to program all consecutive targeted bytes in a single sequence versus using several Page Program (PP) sequences with each containing only a few bytes (see Table 23: AC characteristics (50 MHz operation, T9HX (0.11 m) process) and Table 24: AC characteristics (75 MHz operation, T9HX (0.11 m) process)). Chip Select (S) must be driven High after the eighth bit of the last data byte has been latched in, otherwise the Page Program (PP) instruction is not executed. As soon as Chip Select (S) is driven High, the self-timed Page Program cycle (whose duration is tPP) is initiated. While the Page Program cycle is in progress, the Status Register may be read to check the value of the Write In Progress (WIP) bit. The Write In Progress (WIP) bit is 1 during the self-timed Page Program cycle, and is 0 when it is completed. At some unspecified time before the cycle is complete, the Write Enable Latch (WEL) bit is reset. A Page Program (PP) instruction applied to a page that is hardware protected is not executed. Any Page Program (PP) instruction, while an Erase, Program or Write cycle is in progress, is rejected without having any effects on the cycle that is in progress. 36/64 M25PE20, M25PE10 Figure 17. Page Program (PP) instruction sequence S 0 C Instruction 24-bit address Data byte 1 1 2 3 4 5 6 7 8 9 10 Instructions 28 29 30 31 32 33 34 35 36 37 38 39 D 23 22 21 MSB 3 2 1 0 7 6 5 4 3 2 1 0 MSB S 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 C Data byte 2 Data byte 3 Data byte n D 7 6 5 4 3 2 1 0 7 MSB 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 MSB MSB AI04044 1. Address bits A23 to A18 are `Don't care' in the M25PE20. Address bits A23 to A17 are `Don't care' in the M25PE10. 2. 1 n 256. 37/64 Instructions M25PE20, M25PE10 6.11 Note: Write to Lock Register (WRLR) The Write to Lock Register (WRLR) instruction is decoded only in the T9HX process (see Important note on page 6). The Write to Lock Register (WRLR) instruction allows bits to be changed in the Lock Registers. Before it can be accepted, a Write Enable (WREN) instruction must previously have been executed. After the Write Enable (WREN) instruction has been decoded, the device sets the Write Enable Latch (WEL). The Write to Lock Register (WRLR) instruction is entered by driving Chip Select (S) Low, followed by the instruction code, three address bytes (pointing to any address in the targeted sector and one data byte on Serial Data input (D). The instruction sequence is shown in Figure 18. Chip Select (S) must be driven High after the eighth bit of the data byte has been latched in, otherwise the Write to Lock Register (WRLR) instruction is not executed. Lock Register bits are volatile, and therefore do not require time to be written. When the Write to Lock Register (WRLR) instruction has been successfully executed, the Write Enable Latch (WEL) bit is reset after a delay time less than tSHSL minimum value. Any Write to Lock Register (WRLR) instruction, while an Erase, Program or Write cycle is in progress, is rejected without having any effects on the cycle that is in progress. Figure 18. Write to Lock Register (WRLR) instruction sequence S 0 C Instruction 24-bit address Lock Register value 1 2 3 4 5 6 7 8 9 10 28 29 30 31 32 33 34 35 36 37 38 39 D 23 22 21 MSB 3 2 1 0 7 6 5 4 3 2 1 0 MSB AI10784b Table 12. Lock Register In Sector Bit b7-b2 Value `0' Sector Lock Down bit value Sector Write Lock bit value All sectors b1 b0 38/64 M25PE20, M25PE10 Instructions 6.12 Page Erase (PE) The Page Erase (PE) instruction sets to `1' (FFh) all bits inside the chosen page. Before it can be accepted, a Write Enable (WREN) instruction must previously have been executed. After the Write Enable (WREN) instruction has been decoded, the device sets the Write Enable Latch (WEL). The Page Erase (PE) instruction is entered by driving Chip Select (S) Low, followed by the instruction code, and three address bytes on Serial Data input (D). Any address inside the page is a valid address for the Page Erase (PE) instruction. Chip Select (S) must be driven Low for the entire duration of the sequence. The instruction sequence is shown in Figure 19. Chip Select (S) must be driven High after the eighth bit of the last address byte has been latched in, otherwise the Page Erase (PE) instruction is not executed. As soon as Chip Select (S) is driven High, the self-timed Page Erase cycle (whose duration is tPE) is initiated. While the Page Erase cycle is in progress, the Status Register may be read to check the value of the Write In Progress (WIP) bit. The Write In Progress (WIP) bit is 1 during the selftimed Page Erase cycle, and is 0 when it is completed. At some unspecified time before the cycle is complete, the Write Enable Latch (WEL) bit is reset. A Page Erase (PE) instruction applied to a page that is hardware protected is not executed. Any Page Erase (PE) instruction, while an Erase, Program or Write cycle is in progress, is rejected without having any effects on the cycle that is in progress. Figure 19. Page Erase (PE) instruction sequence S 0 C Instruction 24-bit address 1 2 3 4 5 6 7 8 9 29 30 31 D 23 22 MSB 2 1 0 AI04046 1. Address bits A23 to A18 are `Don't care' in the M25PE20. Address bits A23 to A17 are `Don't care' in the M25PE10. 39/64 Instructions M25PE20, M25PE10 6.13 Note: SubSector Erase (SSE) The SubSector Erase (SSE) instruction is decoded only in the T9HX process (see Important note on page 6). The SubSector Erase (SSE) instruction sets to `1' (FFh) all bits inside the chosen subsector. Before it can be accepted, a Write Enable (WREN) instruction must previously have been executed. After the Write Enable (WREN) instruction has been decoded, the device sets the Write Enable Latch (WEL). The SubSector Erase (SE) instruction is entered by driving Chip Select (S) Low, followed by the instruction code, and three address bytes on Serial Data input (D). Any address inside the SubSector (see Table 5) is a valid address for the SubSector Erase (SE) instruction. Chip Select (S) must be driven Low for the entire duration of the sequence. The instruction sequence is shown in Figure 21. Chip Select (S) must be driven High after the eighth bit of the last address byte has been latched in, otherwise the SubSector Erase (SE) instruction is not executed. As soon as Chip Select (S) is driven High, the self-timed SubSector Erase cycle (whose duration is tSSE) is initiated. While the SubSector Erase cycle is in progress, the Status Register may be read to check the value of the Write In Progress (WIP) bit. The Write In Progress (WIP) bit is 1 during the self-timed SubSector Erase cycle, and is 0 when it is completed. At some unspecified time before the cycle is complete, the Write Enable Latch (WEL) bit is reset. A SubSector Erase (SSE) instruction applied to a subsector that contains a page that is hardware or software protected is not executed. Any SubSector Erase (SSE) instruction, while an Erase, Program or Write cycle is in progress, is rejected without having any effects on the cycle that is in progress. If Reset (Reset) is driven Low while a SubSector Erase (SSE) cycle is in progress, the SubSector Erase cycle is interrupted and data may not be erased correctly (see Table 14: Device status after a Reset Low pulse). On Reset going Low, the device enters the Reset mode and a time of tRHSL is then required before the device can be re-selected by driving Chip Select (S) Low. For the value of tRHSL see Table 26: Timings after a Reset Low pulse in Section 11: DC and AC parameters. Figure 20. SubSector Erase (SSE) instruction sequence S 0 C Instruction 24-bit address 1 2 3 4 5 6 7 8 9 29 30 31 D 23 22 MSB 2 1 0 AI12356 1. Address bits A23 to A18 are `Don't care' in the M25PE20. Address bits A23 to A17 are `Don't care' in the M25PE10. 40/64 M25PE20, M25PE10 Instructions 6.14 Sector Erase (SE) The Sector Erase (SE) instruction sets to `1' (FFh) all bits inside the chosen sector. Before it can be accepted, a Write Enable (WREN) instruction must previously have been executed. After the Write Enable (WREN) instruction has been decoded, the device sets the Write Enable Latch (WEL). The Sector Erase (SE) instruction is entered by driving Chip Select (S) Low, followed by the instruction code, and three address bytes on Serial Data input (D). Any address inside the sector (see Table 5 or Table 6) is a valid address for the Sector Erase (SE) instruction. Chip Select (S) must be driven Low for the entire duration of the sequence. The instruction sequence is shown in Figure 21. Chip Select (S) must be driven High after the eighth bit of the last address byte has been latched in, otherwise the Sector Erase (SE) instruction is not executed. As soon as Chip Select (S) is driven High, the self-timed Sector Erase cycle (whose duration is tSE) is initiated. While the Sector Erase cycle is in progress, the Status Register may be read to check the value of the Write In Progress (WIP) bit. The Write In Progress (WIP) bit is 1 during the self-timed Sector Erase cycle, and is 0 when it is completed. At some unspecified time before the cycle is complete, the Write Enable Latch (WEL) bit is reset. A Sector Erase (SE) instruction applied to a sector that contains a page that is hardware protected is not executed. Any Sector Erase (SE) instruction, while an Erase, Program or Write cycle is in progress, is rejected without having any effects on the cycle that is in progress. Figure 21. Sector Erase (SE) instruction sequence S 0 C Instruction 24-bit address 1 2 3 4 5 6 7 8 9 29 30 31 D 23 22 MSB 2 1 0 AI03751D 1. Address bits A23 to A18 are `Don't care' in the M25PE20. Address bits A23 to A17 are `Don't care' in the M25PE10. 41/64 Instructions M25PE20, M25PE10 6.15 Note: Bulk Erase (BE) The Bulk Erase (BE) instruction is decoded only in the T9HX process (see Important note on page 6). The Bulk Erase (BE) instruction sets all bits to `1' (FFh). Before it can be accepted, a Write Enable (WREN) instruction must previously have been executed. After the Write Enable (WREN) instruction has been decoded, the device sets the Write Enable Latch (WEL). The Bulk Erase (BE) instruction is entered by driving Chip Select (S) Low, followed by the instruction code on Serial Data input (D). Chip Select (S) must be driven Low for the entire duration of the sequence. The instruction sequence is shown in Figure 22. Chip Select (S) must be driven High after the eighth bit of the instruction code has been latched in, otherwise the Bulk Erase instruction is not executed. As soon as Chip Select (S) is driven High, the self-timed Bulk Erase cycle (whose duration is tBE) is initiated. While the Bulk Erase cycle is in progress, the Status Register may be read to check the value of the Write In Progress (WIP) bit. The Write In Progress (WIP) bit is 1 during the self-timed Bulk Erase cycle, and is 0 when it is completed. At some unspecified time before the cycle is completed, the Write Enable Latch (WEL) bit is reset. Any Bulk Erase (BE) instruction, while an Erase, Program or Write cycle is in progress, is rejected without having any effects on the cycle that is in progress. A Bulk Erase (BE) instruction is ignored if at least one sector or subsector is write-protected (hardware or software protection). If Reset (Reset) is driven Low while a Bulk Erase (BE) cycle is in progress, the Bulk Erase cycle is interrupted and data may not be erased correctly (see Table 14: Device status after a Reset Low pulse). On Reset going Low, the device enters the Reset mode and a time of tRHSL is then required before the device can be re-selected by driving Chip Select (S) Low. For the value of tRHSL see Table 26: Timings after a Reset Low pulse in Section 11: DC and AC parameters. Figure 22. Bulk Erase (BE) instruction sequence S 0 C Instruction D 1 2 3 4 5 6 7 AI03752D 42/64 M25PE20, M25PE10 Instructions 6.16 Deep Power-down (DP) Executing the Deep Power-down (DP) instruction is the only way to put the device in the lowest consumption mode (the Deep Power-down mode). It can also be used as an extra software protection mechanism, while the device is not in active use, since in this mode, the device ignores all write, program and erase instructions. Driving Chip Select (S) High deselects the device, and puts the device in Standby Power mode (if there is no internal cycle currently in progress). But this mode is not the Deep Power-down mode. The Deep Power-down mode can only be entered by executing the Deep Power-down (DP) instruction, subsequently reducing the standby current (from ICC1 to ICC2, as specified in Table 19). Once the device has entered the Deep Power-down mode, all instructions are ignored except the Release from Deep Power-down (RDP) instruction. This releases the device from this mode. The Deep Power-down mode automatically stops at power-down, and the device always powers up in Standby Power mode. The Deep Power-down (DP) instruction is entered by driving Chip Select (S) Low, followed by the instruction code on Serial Data input (D). Chip Select (S) must be driven Low for the entire duration of the sequence. The instruction sequence is shown in Figure 23. Chip Select (S) must be driven High after the eighth bit of the instruction code has been latched in, otherwise the Deep Power-down (DP) instruction is not executed. As soon as Chip Select (S) is driven High, it requires a delay of tDP before the supply current is reduced to ICC2 and the Deep Power-down mode is entered. Any Deep Power-down (DP) instruction, while an Erase, Program or Write cycle is in progress, is rejected without having any effects on the cycle that is in progress. Figure 23. Deep Power-down (DP) instruction sequence S 0 C Instruction D 1 2 3 4 5 6 7 tDP Standby Power mode Deep Power-down mode AI03753D 43/64 Instructions M25PE20, M25PE10 6.17 Release from Deep Power-down (RDP) Once the device has entered the Deep Power-down mode, all instructions are ignored except the Release from Deep Power-down (RDP) instruction. Executing this instruction takes the device out of the Deep Power-down mode. The Release from Deep Power-down (RDP) instruction is entered by driving Chip Select (S) Low, followed by the instruction code on Serial Data input (D). Chip Select (S) must be driven Low for the entire duration of the sequence. The instruction sequence is shown in Figure 24. The Release from Deep Power-down (RDP) instruction is terminated by driving Chip Select (S) High. Sending additional clock cycles on Serial Clock (C), while Chip Select (S) is driven Low, cause the instruction to be rejected, and not executed. After Chip Select (S) has been driven High, followed by a delay, tRDP, the device is put in Standby Power mode. Chip Select (S) must remain High at least until this period is over. The device waits to be selected, so that it can receive, decode and execute instructions. Any Release from Deep Power-down (RDP) instruction, while an Erase, Program or Write cycle is in progress, is rejected without having any effects on the cycle that is in progress. Figure 24. Release from Deep Power-down (RDP) instruction sequence S 0 C Instruction D 1 2 3 4 5 6 7 tRDP High Impedance Q Deep Power-down mode Standby Power mode AI06807 44/64 M25PE20, M25PE10 Power-up and power-down 7 Power-up and power-down At power-up and power-down, the device must not be selected (that is Chip Select (S) must follow the voltage applied on VCC) until VCC reaches the correct value: VCC(min) at power-up, and then for a further delay of tVSL VSS at power-down A safe configuration is provided in Section 3: SPI modes. To avoid data corruption and inadvertent write operations during power-up, a power on reset (POR) circuit is included. The logic inside the device is held reset while VCC is less than the power on reset (POR) threshold value, VWI - all operations are disabled, and the device does not respond to any instruction. Moreover, the device ignores all Write Enable (WREN), Page Write (PW), Page Program (PP), Page Erase (PE) and Sector Erase (SE) instructions until a time delay of tPUW has elapsed after the moment that VCC rises above the VWI threshold. However, the correct operation of the device is not guaranteed if, by this time, VCC is still below VCC(min). No write, program or erase instructions should be sent until the later of: tPUW after VCC passed the VWI threshold tVSL after VCC passed the VCC(min) level These values are specified in Table 13. If the delay, tVSL, has elapsed, after VCC has risen above VCC(min), the device can be selected for read instructions even if the tPUW delay is not yet fully elapsed. As an extra protection, the Reset (Reset) signal could be driven Low for the whole duration of the power-up and power-down phases. At power-up, the device is in the following state: The device is in the Standby Power mode (not the Deep Power-down mode) The Write Enable Latch (WEL) bit is reset The Write In Progress (WIP) bit is reset The Lock Registers are reset (Write Lock bit, Lock Down bit) = (0, 0). Normal precautions must be taken for supply rail decoupling, to stabilize the VCC supply. Each device in a system should have the VCC rail decoupled by a suitable capacitor close to the package pins. (Generally, this capacitor is of the order of 100 nF). At power-down, when VCC drops from the operating voltage, to below the power on reset (POR) threshold voltage, VWI, all operations are disabled and the device does not respond to any instruction. The designer needs to be aware that if a power-down occurs while a Write, Program or Erase cycle is in progress, some data corruption can result. 45/64 Power-up and power-down Figure 25. Power-up timing VCC VCC(max) Program, Erase and Write commands are rejected by the device Chip selection not allowed VCC(min) Reset state of the device VWI tPUW tVSL M25PE20, M25PE10 Read access allowed Device fully accessible time AI04009C Table 13. Symbol tVSL (1) Power-up timing and VWI threshold Parameter VCC(min) to S low Time delay before the first write, program or erase instruction Write inhibit voltage Min. 30 1 1.5 10 2.5 Max. Unit s ms V tPUW(1) VWI(1) 1. These parameters are characterized only, over the temperature range -40 C to +85 C. 46/64 M25PE20, M25PE10 Reset 8 Reset Driving Reset (Reset) Low while an internal operation is in progress will affect this operation (write, program or erase cycle) and data may be lost. All the Lock bits are reset to `0' after a Reset Low pulse. Table 14 shows the status of the device after a Reset Low pulse. Table 14. Device status after a Reset Low pulse Conditions: Reset pulse occurred While decoding an instruction(1): WREN, WRDI, RDID, RDSR, READ, RDLR, Fast_Read, WRLR, PW, PP, PE, SE, BE, SSE, DP, RDP Under completion of an Erase or Program cycle of a PW, PP, PE, SSE, SE, BE operation Under completion of a WRSR operation Device deselected (S High) and in Standby mode 1. S remains Low while Reset is Low. Lock bits status Internal logic status Addressed data Reset to `0' Same as POR Not significant Reset to `0' Equivalent to POR Equivalent to POR (after tW) Same as POR Addressed data could be modified Write is correctly completed Not significant Reset to `0' Reset to `0' 9 Initial delivery state The device is delivered with the memory array erased: all bits are set to `1' (each byte contains FFh). All usable Status Register bits are 0. 47/64 Maximum ratings M25PE20, M25PE10 10 Maximum ratings Stressing the device above the rating listed in Table 15: Absolute maximum ratings may cause permanent damage to the device. These are stress ratings only and operation of the device at these or any other conditions above those indicated in the operating sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Refer also to the Numonyx SURE Program and other relevant quality documents. Table 15. Symbol TSTG TLEAD VIO VCC VESD Storage temperature Lead temperature during soldering Input and output voltage (with respect to ground) Supply voltage Electrostatic discharge voltage (Human Body model)(2) Absolute maximum ratings Parameter Min. -65 Max. 150 Unit C C V V V See note (1) -0.6 -0.6 -2000 VCC + 0.6 4.0 2000 1. Compliant with JEDEC Std J-STD-020C (for small body, Sn-Pb or Pb assembly), the Numonyx ECOPACK(R) 7191395 specification, and the European directive on Restrictions on Hazardous Substances (RoHS) 2002/95/EU. 2. JEDEC Std JESD22-A114A (C1 = 100 pF, R1 = 1500 , R2 = 500 ). 48/64 M25PE20, M25PE10 DC and AC parameters 11 DC and AC parameters This section summarizes the operating and measurement conditions, and the DC and AC characteristics of the devices. The parameters in the DC and AC characteristic tables that follow are derived from tests performed under the measurement conditions summarized in the relevant tables. Designers should check that the operating conditions in their circuit match the measurement conditions when relying on the quoted parameters. Table 16. Symbol VCC TA Supply voltage Ambient operating temperature Operating conditions Parameter Min. 2.7 -40 Max. 3.6 85 Unit V C Table 17. Symbol CL AC measurement conditions Parameter Load capacitance Input rise and fall times Input pulse voltages Input and output timing reference voltages Min. 30 5 0.2VCC to 0.8VCC 0.3VCC to 0.7VCC Max. Unit pF ns V V 1. Output Hi-Z is defined as the point where data out is no longer driven. Figure 26. AC measurement I/O waveform Input levels 0.8VCC Input and output timing reference levels 0.7VCC 0.3VCC AI00825B 0.2VCC Table 18. Symbol COUT CIN Capacitance(1) Parameter Output capacitance (Q) Input capacitance (other pins) Test condition VOUT = 0 V VIN = 0 V Min. Max. 8 6 Unit pF pF 1. Sampled only, not 100% tested, at TA=25 C and a frequency of 25 MHz. 49/64 DC and AC parameters Table 19. Symbol ILI ILO ICC1 ICC2 M25PE20, M25PE10 DC characteristics Parameter Test condition (in addition to those in Table 16) Min. Max. 2 2 S = VCC, VIN = VSS or VCC S = VCC, VIN = VSS or VCC C = 0.1VCC / 0.9.VCC at 20 MHz, Q = open C = 0.1VCC / 0.9.VCC at 33 MHz, Q = open S = VCC S = VCC - 0.5 0.7VCC IOL = 1.6 mA IOH = -100 A VCC-0.2 50 10 6 mA 8 15 15 0.3VCC VCC+0.4 0.4 mA mA V V V V Unit A A A A Input Leakage current Output Leakage current Standby current (Standby and Reset modes) Deep Power-down current ICC3 Operating current (FAST_READ) ICC4 ICC5 VIL VIH VOL VOH Operating current (PW) Operating current (SE) Input Low voltage Input High voltage Output Low voltage Output High voltage Table 20. Symbol ILI ILO ICC1 DC characteristics (T9HX (0.11 m) process) Parameter Input Leakage current Output Leakage current Standby current (Standby and Reset modes) Deep Power-down current S = VCC, VIN = VSS or VCC Test condition (in addition to those in Table 16) Min. Max. 2 2 50 Unit A A A ICC2 S = VCC, VIN = VSS or VCC C = 0.1VCC / 0.9.VCC at 33 MHz, Q = open C = 0.1VCC / 0.9.VCC at 75 MHz, Q = open S = VCC S = VCC - 0.5 0.7VCC IOL = 1.6 mA IOH = -100 A VCC-0.2 10 4 A ICC3 Operating current (FAST_READ) mA 12 15 15 0.3VCC VCC+0.4 0.4 mA mA V V V V ICC4 ICC5 VIL VIH VOL VOH Operating current (PW) Operating current (SE) Input Low voltage Input High voltage Output Low voltage Output High voltage 50/64 M25PE20, M25PE10 Table 21. AC characteristics (25 MHz operation) DC and AC parameters Test conditions specified in Table 16 and Table 17 Symbol fC fR tCH(1) tCL(1) tCLH tCLL Alt. fC Parameter Clock frequency for the following instructions: FAST_READ, PW, PP, PE, SE, DP, RDP, WREN, WRDI, RDSR Clock frequency for read instructions Clock High time Clock Low time Clock Slew rate(2)(peak to peak) tSLCH tCHSL tDVCH tCHDX tCHSH tSHCH tSHSL tSHQZ(2) tCLQV tCLQX tTHSL tSHTL tDP(2) tRDP(2) tPW(3) tCSH tDIS tV tHO tDSU tDH tCSS S Active Setup time (relative to C) S Not Active Hold time (relative to C) Data In Setup time Data In Hold time S Active Hold time (relative to C) S Not Active Setup time (relative to C) S Deselect time Output Disable time Clock Low to Output Valid Output Hold time Top Sector Lock Setup time Top Sector Lock Hold time S to Deep Power-down S High to Standby Power mode Page Write cycle time (256 bytes) Page Write cycle time (n bytes) Page Program cycle time (256 bytes) tPP(3) tPE tSE Page Program cycle time (n bytes) Page Erase cycle time Sector Erase cycle time 11 10.2 + n*0.8/256 1.2 0.4 + n*0.8/256 10 1 5 ms 25 ms 0 50 100 3 30 Min. D.C. D.C. 18 18 0.1 10 10 5 5 10 10 200 15 15 Typ. Max. 25 20 Unit MHz MHz ns ns V/ns ns ns ns ns ns ns ns ns ns ns ns ns s s 20 5 ms s 1. tCH + tCL must be greater than or equal to 1/ fC. 2. Value guaranteed by characterization, not 100% tested in production. 3. When using PP and PW instructions to update consecutive bytes, optimized timings are obtained with one sequence including all the bytes versus several sequences of only a few bytes (1 n 256). 51/64 DC and AC parameters Table 22. AC characteristics (33 MHz operation) M25PE20, M25PE10 33 MHz only available for products marked since week 40 of 2005(1). Test conditions specified in Table 16 and Table 17 Symbol fC fR tCH(2) tCL(2) tCLH tCLL Alt. fC Parameter Clock frequency for the following instructions: FAST_READ, PW, PP, PE, SE, DP, RDP, WREN, WRDI, RDSR Clock frequency for READ instructions Clock High time Clock Low time Clock Slew rate tSLCH tCHSL tDVCH tCHDX tCHSH tSHCH tSHSL tSHQZ(3) tCLQV tCLQX tTHSL tSHTL tDP(3) tRDP(3) tPW(4) tCSH tDIS tV tHO tDSU tDH tCSS (3) Min. D.C. D.C. 13 13 Typ. Max. 33 20 Unit MHz MHz ns ns V/ns ns ns ns ns ns ns ns (peak to peak) 0.1 10 10 3 5 5 5 200 12 12 0 50 100 3 30 11 10.2+ n*0.8/256 1.2 0.4+ n*0.8/256 10 1 5 25 S Active Setup time (relative to C) S Not Active Hold time (relative to C) Data In Setup time Data In Hold time S Active Hold time (relative to C) S Not Active Setup time (relative to C) S Deselect time Output Disable time Clock Low to Output Valid Output Hold time Top Sector Lock Setup time Top Sector Lock Hold time S to Deep Power-down S High to Standby Power mode Page Write cycle time (256 bytes) Page Write cycle time (n bytes) Page Program cycle time (256 bytes) ns ns ns ns ns s s ms tPP(4) tPE tSE ms Page Program cycle time (n bytes) Page Erase cycle time Sector Erase cycle time 20 5 ms s 1. Details of how to find the date of marking are given in application note, AN1995. 2. tCH + tCL must be greater than or equal to 1/ fC. 3. Value guaranteed by characterization, not 100% tested in production. 4. When using PP and PW instructions to update consecutive bytes, optimized timings are obtained with one sequence including all the bytes versus several sequences of only a few bytes (1 n 256). 52/64 M25PE20, M25PE10 Table 23. DC and AC parameters AC characteristics (50 MHz operation, T9HX (0.11 m) process(1))(2) Test conditions specified in Table 16 and Table 17 Symbol fC fR tCH(3) tCL(3) tSLCH tCHSL tDVCH tCHDX tCHSH tSHCH tSHSL tSHQZ(4) tCLQV tCLQX tWHSL(5) tSHWL(5) tDP(4) tRDP(4) tW tPW(6) tPP(6) tPE tSE tSSE tBE Alt. fC Parameter Clock frequency for the following instructions: FAST_READ, RDLR, PW, PP, WRLR, PE, SE, SSE, DP, RDP, WREN, WRDI, RDSR, WRSR Clock frequency for READ instructions Min. D.C. D.C. 9 9 Typ. Max. 50 33 Unit MHz MHz ns ns V/ns ns ns ns ns ns ns ns tCLH tCLL tCSS tDSU tDH Clock High time Clock Low time Clock Slew Rate (peak to peak) S Active Setup time (relative to C) S Not Active Hold time (relative to C) Data In Setup time Data In Hold time S Active Hold time (relative to C) S Not Active Setup time (relative to C) 2 0.1 5 5 2 5 5 5 100 8 8 0 50 100 3 30 3 11 0.8 int(n/8) x 0.025(7) 10 1.5 80 4.5 15 23 3 20 5 150 10 tCSH tDIS tV tHO S Deselect time Output Disable time Clock Low to Output Valid Output Hold time Write Protect Setup time Write Protect Hold time S to Deep Power-down S High to Standby mode Write Status Register cycle time Page Write cycle time (256 bytes) Page Program cycle time (256 bytes) Page Program cycle time (n bytes) Page Erase cycle time Sector Erase cycle time SubSector Erase cycle time Bulk Erase cycle time ns ns ns ns ns s s ms ms ms ms s ms s 1. See Important note on page 6. 2. Details of how to find the technology process in the marking are given in AN1995, see also Section 13: Ordering information. 3. tCH + tCL must be greater than or equal to 1/ fC. 4. Value guaranteed by characterization, not 100% tested in production. 5. Only applicable as a constraint for a WRSR instruction when SRWD is set to `1'. 6. When using PP and PW instructions to update consecutive bytes, optimized timings are obtained with one sequence including all the bytes versus several sequences of only a few bytes (1 n 256). 7. int(A) corresponds to the upper integer part of A. E.g. int(12/8) = 2, int(32/8) = 4 int(15.3) =16. 53/64 DC and AC parameters Table 24. M25PE20, M25PE10 AC characteristics (75 MHz operation, T9HX (0.11 m) process(1))(2) Test conditions specified in Table 16 and Table 17 Symbol fC fR tCH(3) tCL(2) tSLCH tCHSL tDVCH tCHDX tCHSH tSHCH tSHSL tSHQZ(4) tCLQV tCLQX tWHSL (5) Alt. fC Parameter Clock frequency for the following instructions: FAST_READ, RDLR, PW, PP, WRLR, PE, SE, SSE, DP, RDP, WREN, WRDI, RDSR, WRSR Clock frequency for READ instructions Min. D.C. D.C. 6 6 Typ. Max. 75 33 Unit MHz MHz ns ns V/ns ns ns ns ns ns ns ns tCLH tCLL tCSS tDSU tDH Clock High time Clock Low time Clock Slew Rate (peak to peak) S Active Setup time (relative to C) S Not Active Hold time (relative to C) Data In Setup time Data In Hold time S Active Hold time (relative to C) S Not Active Setup time (relative to C) 2 0.1 5 5 2 5 5 5 100 8 8/6 0 20 100 3 30 3 11 0.8 int(n/8) x 0.025(7) 10 1.5 80 4.5 3 20 5 150 10 15 23 tCSH tDIS tV tHO S Deselect time Output Disable time Clock Low to Output Valid under 30 pF/10 pF Output Hold time Write Protect Setup time Write Protect Hold time S to Deep Power-down S High to Standby mode Write Status Register cycle time Page Write cycle time (256 bytes) Page Program cycle time (256 bytes) ns ns ns ns ns s s ms ms ms ms s ms s tSHWL(4) tDP(4) tRDP(4) tW tPW(6) tPP(5) tPE tSE tSSE tBE Page Program cycle time (n bytes) Page Erase cycle time Sector Erase cycle time SubSector Erase cycle time Bulk Erase cycle time 1. See Important note on page 6. 2. Details of how to find the technology process in the marking are given in AN1995, see also Section 13: Ordering information. 3. tCH + tCL must be greater than or equal to 1/ fC. 4. Value guaranteed by characterization, not 100% tested in production. 5. Only applicable as a constraint for a WRSR instruction when SRWD is set to `1'. 6. When using PP and PW instructions to update consecutive bytes, optimized timings are obtained with one sequence including all the bytes versus several sequences of only a few bytes (1 n 256). 7. int(A) corresponds to the upper integer part of A. E.g. int(12/8) = 2, int(32/8) = 4 int(15.3) =16. 54/64 M25PE20, M25PE10 Figure 27. Serial input timing DC and AC parameters tSHSL S tCHSL C tDVCH tCHDX D MSB IN tCLCH LSB IN tCHCL tSLCH tCHSH tSHCH Q High Impedance AI01447C Figure 28. Top Sector Lock (T7X process) or Write Protect (T9HX process) setup and hold timing TSL or W tTHSL tWHSL S tSHTL tSHWL C D High Impedance Q AI3559 1. For the differences between devices produced in the two processes, see Important note on page 6. 55/64 DC and AC parameters Figure 29. Output timing S tCH C tCLQV tCLQX Q tQLQH tQHQL D ADDR.LSB IN M25PE20, M25PE10 tCLQV tCLQX tCL tSHQZ LSB OUT AI01449e Table 25. Reset conditions Test conditions specified in Table 16 and Table 17 Symbol tRLRH(1) tSHRH Alt. tRST Parameter Reset Pulse width Conditions Min. 10 10 Typ. Max. Unit s ns Chip Select High to Reset Chip should have been deselected High before Reset is de-asserted 1. Value guaranteed by characterization, not 100% tested in production. Table 26. Timings after a Reset Low pulse(1)(2) Test conditions specified in Table 16 and Table 17 Symbol Alt. Parameter Conditions: Reset pulse occurred While decoding an instruction(3): WREN, WRDI, RDID, RDSR, READ, RDLR, Fast_Read, WRLR, PW, PP, PE, SE, BE, SSE, DP, RDP Under completion of an Erase or Program cycle of a PW, PP, PE, SE, BE operation Max. Unit 30 s 300 3 tW (see Table 23 or Table 24) 0 s ms tRHSL tREC Reset recovery time Under completion of an Erase cycle of an SSE operation Under completion of a WRSR operation Device deselected (S High) and in Standby mode ms s 1. All the values are guaranteed by characterization, and not 100% tested in production. 2. See Table 14 for a description of the device status after a Reset Low pulse. 3. S remains Low while Reset is Low. 56/64 M25PE20, M25PE10 Figure 30. Reset AC waveforms DC and AC parameters S tSHRH tRLRH tRHSL Reset AI06808 57/64 Package mechanical M25PE20, M25PE10 12 Package mechanical In order to meet environmental requirements, Numonyx offers these devices in ECOPACK(R) packages. ECOPACK(R) packages are lead-free. The category of second level interconnect is marked on the package and on the inner box label, in compliance with JEDEC Standard JESD97. The maximum ratings related to soldering conditions are also marked on the inner box label. Figure 31. SO8N - 8 lead Plastic small outline, 150 mils body width, package outline h x 45 A2 b e 0.25 mm GAUGE PLANE k 8 A ccc c D E1 1 E A1 L L1 SO-A 1. Drawing is not to scale. 58/64 M25PE20, M25PE10 Table 27. Package mechanical SO8N - 8 lead plastic small outline, 150 mils body width, package mechanical data millimeters inches Max 1.75 0.10 1.25 0.28 0.17 0.48 0.23 0.10 4.90 6.00 3.90 1.27 4.80 5.80 3.80 - 0.25 0 0.40 1.04 5.00 6.20 4.00 - 0.50 8 1.27 0.041 0.193 0.236 0.154 0.050 0.189 0.228 0.150 - 0.010 0 0.016 0.25 0.004 0.049 0.011 0.007 0.019 0.009 0.004 0.197 0.244 0.157 - 0.020 8 0.050 Typ Min Max 0.069 0.010 Symbol Typ A A1 A2 b c ccc D E E1 e h k L L1 Min 59/64 Package mechanical M25PE20, M25PE10 Figure 32. VFQFPN8 (MLP8), 8-lead very thin fine pitch quad flat package no lead, 6 x 5 mm, package outline A R1 D1 B MCAB bbb D aaa C A E E1 E2 e 2x 0.10 C B aaa C B b 0.10 C A A2 D2 L ddd A A1 A3 C 70-ME 1. Drawing is not to scale. Table 28. VFQFPN8 (MLP8), 8-lead very thin fine pitch quad flat package no lead, 6 x 5 mm, package mechanical data millimeters inches Max 1.00 0.05 0.026 0.008 0.35 0.48 0.016 0.236 0.226 3.20 3.60 0.134 0.197 0.187 3.80 - 0.00 0.50 0.75 12 0.15 0.10 0.05 4.30 - 0.157 0.050 0.004 0.024 0.150 - 0.000 0.020 0.029 12 0.006 0.004 0.002 0.169 - 0.126 0.142 0.014 0.019 Typ 0.033 Min 0.031 0.000 Max 0.039 0.002 Symbol Typ A A1 A2 A3 b D D1 D2 E E1 E2 e R1 L aaa bbb ddd 0.65 0.20 0.40 6.00 5.75 3.40 5.00 4.75 4.00 1.27 0.10 0.60 0.85 Min 0.80 0.00 60/64 M25PE20, M25PE10 Ordering information 13 Ordering information Table 29. Example: Ordering information scheme M25PE20 - V MN 6 TG Device type M25PE = Page-erasable serial Flash memory Device function 10 = 1 Mbit (128 K x 8) 20 = 2 Mbit (256 K x 8) Operating voltage V = VCC = 2.7 V to 3.6 V Package MN = SO8N (150 mil width) MP = VFQFPN8 6 x 5 mm (MLP8)(1) Device grade 6 = Industrial: device tested with standard test flow over -40 to 85 C Option blank = Standard packing T = Tape and reel packing Plating technology P or G = ECOPACK(R) (RoHS compliant) 1. Package only available for products in the T9HX process. Note: For a list of available options (speed, package, etc.), for further information on any aspect of this device or when ordering parts operating at 75 MHz (0.11 m, process digit `4'), please contact your nearest Numonyx Sales Office. 61/64 Revision history M25PE20, M25PE10 14 Revision history Table 30. Date 07-Dec-2004 21-Dec-2004 Document revision history Version 0.1 0.2 Document written Notes 1 and 2 removed from Table 29: Ordering information scheme. S08N silhouette corrected on page 1. Added Table 22: AC characteristics (33 MHz operation). Document status promoted to full Datasheet. An easy way to modify data, A fast way to modify data, Page Write (PW) and Page Program (PP) sections updated to explain optimal use of Page Write and Page Program instructions. Clock slew rate changed from 0.03 to 0.1 V/ns. Updated Table 29: Ordering information scheme. Added ECOPACK(R) information. Document converted to the new Numonyx template. MLP package removed, SO8N package specifications updated (see Section 12: Package mechanical). Figure 5: SPI modes supported updated and Note 2 added. Timing line of tSHQZ moved in Figure 29. 50 MHz frequency added. VFQFPN package added (see Section 12: Package mechanical). The sectors are further divided up into subsectors (see Table 5: M25PE20 memory organization and Table 6: M25PE10 memory organization). Important note on page 6 added. Figure 4: Bus master and memory devices on the SPI bus updated and explanatory paragraph added. VCC supply voltage and VSS ground added. Section 4.8: Protection modes modified. Section 8: Reset added, Reset timings table split into Table 25: Reset conditions and Table 26: Timings after a Reset Low pulse. At power-up the WIP bit is reset and the Lock Registers are reset (see Section 7: Power-up and power-down). VIO max changed in Table 15: Absolute maximum ratings. M25PE20 and M25PE10 products processed in T9HX process added to datasheet: - WP pin replaces TSL (T7X technology), see Section 2.7: Write Protect (W) or Top Sector Lock (TSL) - Read Lock Register (RDLR), Write to Lock Register (WRLR), Write Status Register (WRSR), SubSector Erase (SSE) and Bulk Erase (BE) instructions added for T9HX process - subsector protection granularity removed in T9HX process, still exists in T7X process - Table 5: M25PE20 memory organization and Table 6: M25PE10 memory organization updated to show subsectors - Status Register BP1, BP0 bits and SRWD bit added. Small text changes. Changes 6-Oct-2005 1.0 10-Jul-2006 2 25-Jan-2007 3 62/64 M25PE20, M25PE10 Table 30. Date Revision history Document revision history (continued) Version Changes Removed `low voltage' from the title. Updated the value for the maximum clock frequency (from 50 to 75 MHz) through the document. Added: Table 20: DC characteristics (T9HX (0.11 m) process), Table 24: AC characteristics (75 MHz operation, T9HX (0.11 m) process) and ECOPACK(R) text in Section 12: Package mechanical. Modified: Table 22: AC characteristics (33 MHz operation), Figure 4: Bus master and memory devices on the SPI bus, and Section 6.3: Read Identification (RDID). Applied Numonyx branding. 30-Jan-2008 4 20-Mar-2008 5 63/64 M25PE20, M25PE10 Please Read Carefully: INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH NUMONYXTM PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN NUMONYX'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, NUMONYX ASSUMES NO LIABILITY WHATSOEVER, AND NUMONYX DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF NUMONYX PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. Numonyx products are not intended for use in medical, life saving, life sustaining, critical control or safety systems, or in nuclear facility applications. Numonyx may make changes to specifications and product descriptions at any time, without notice. Numonyx, B.V. may have patents or pending patent applications, trademarks, copyrights, or other intellectual property rights that relate to the presented subject matter. The furnishing of documents and other materials and information does not provide any license, express or implied, by estoppel or otherwise, to any such patents, trademarks, copyrights, or other intellectual property rights. Designers must not rely on the absence or characteristics of any features or instructions marked "reserved" or "undefined." Numonyx reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them. Contact your local Numonyx sales office or your distributor to obtain the latest specifications and before placing your product order. Copies of documents which have an order number and are referenced in this document, or other Numonyx literature may be obtained by visiting Numonyx's website at http://www.numonyx.com. Numonyx StrataFlash is a trademark or registered trademark of Numonyx or its subsidiaries in the United States and other countries. *Other names and brands may be claimed as the property of others. Copyright (c) 11/5/7, Numonyx, B.V., All Rights Reserved. 64/64 |
Price & Availability of M25PE20 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |