![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Sensing element/Gauge Features . Dual-In-line-Package (DIP)or SMD, Easy to mount on PCB . Vacuum pressure measurable FPN,FGN-6 Data sheet Applications . Home use Non-Invasive Blood Pressure(NIBP)monitors . Vacuum cleaner . Washing machine Part number for ordering FGN - 6 07P G S R Model FPN FGN Rated pressure (PSI) Length of the pressure port (FGN only) Pressure type 6 : 6mm G : Gauge Terminal leads direction(See Outline Diagram) No mark : R: Terminal leads configuration No mark : DIP(FPN) S : Surface mount package(FGN) Pressure type FPN Gauge pressure FGN-6 Model Package configuration Dual-In-line-Package(DIP) Surface mount package, 6mm pressure port Measurable pressure range(kPa) 13.79 13.79 34.47 34.47 48.26 48.26 98.07 103.4 FPN-02PG FPN-05PG FPN-07PG FPN-15PG Part number for ordering FPN-02PGR FPN-05PGR FPN-07PGR FPN-15PGR FGN-602PGSR FGN-605PGSR FGN-607PGSR FGN-615PGSR Specifications Model/Rated pressure Recommended operating conditions Pressure type Rated pressure 13.79 0.141 13.79 13.79 02PG 05PG 07PG 15PG unit Measurable pressure range Pressure media Excitation current(Constant) Absolute maximum rating Maximum load pressure Twice of rated pressure Maximum excitation current 3.0 Operating temperature 0 80 Storage temperature 20 100 Operating humidity 30 80(No dew condensation) Electric performances/characteristics(Excitation current I=1.5mA constant, Ambient temperature Ta=25 ) Full scale span voltage 40 130 Offset voltage 40 25 Bridge impedance 4000 6000 Mechanical response time 2(For the reference) Temperature sensitivity of offset(TSO) 10.0 8.0 Temperature coefficient of sensitivity(TCS) 5.0 2.5 Linearity 0.6 0.3 Pressure hystersis 1.0 0.7 Accuracy Gauge pressure 34.47 48.26 0.352 0.492 34.47 34.47 48.26 48.26 Non-corrosive gas 1.5 103.4 1.055 98.07 103.4 kPa kg/cm2 kPa mADC mADC RH mV mV msec FS/0 50 FS/0 50 FS FS 1 Sensing element/Gauge Outline dimensions FPN,FGN-6 Data sheet unit(mm) FPN 12 6 5 4 4 2.2 8 5 0.2 max 15 Pressure port 0.8 0.6 Vent hole 4.5 4 5 6 15.24(600mil) R1.5 3 C0.5 14 1 2 3 Terminal leads 3 2 1 Labelled faceplate 6.8 2.8 Recommended footprint for PCB 6- 0.9(Diameter of through holes) 2.54 2.54 6- 1.8(Diameter of lands) 1.2 60 15.2 unit(mm) unit(mm) FPN-R 0.2 12 max 15 4 2.2 8 5 6 5 4 0.8 Pressure port 4 5 6 R1.5 14 3 C0.5 1 2 3 Terminal leads Labelled faceplate 0.6 Vent hole 32 4.5 1 0.5 15.24(600mil) 2.54 2.54 Recommended footprint for PCB 6- 0.9(Diameter of through holes) 6- 1.8(Diameter of lands) 1.2 60 2.8 6.8 15.2 unit(mm) 2 2.54 2.54 2.54 2.54 0.5 Sensing element/Gauge Outline dimensions FPN,FGN-6 Data sheet unit(mm) FGN-6 Pressure port 1 2.54 2.54 0.8 2 3 7 6 5 7 4 3 Vent hole Index 6 9.5 0.8 10.3 15 MA Projections 0.5 X. 0.25 3.5 Labelled faceplate 6 5 4 2-R0.5 Recommended footprint for PCB 1.7 1.4 2- 1(Holes for projections) 2.54 2.54 6.2 9.4 1 Projections 1 2 3 Land-pads unit(mm) Connection diagram unit(mm) FPN, FGN-6 i 1.5mA 2 Output voltage R2 Constant current source 3 6 R3 R4 1 6 Zero balancing trimmer (VR0) is available. VR0 :200 R1 1 5 VR0 Note ; Please read instruction "Notes" before using the sensor. Fujikura reserves the right to change specifications without notice. If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538 3 E-mail : sensor@fujikura.co.jp 6.2 |
Price & Availability of FPN-07PG
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |