![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Presente / Presents: DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Quebec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com NHG RELAYS JQ104E 40 35 36 Features Small size and light weight. Heavy contact load (100A). Contact arrangement Form A and C available. Suitable for automobile and lamp accessories application. PC board mounting and direct insert mounting available. Ordering Information JQ104E 1 A 2 Z 3 100 b 4 5 DC12V 6 N 7 5 6 7 8 D 8 1Part number NVF7 2Contact arrangement A:1A 3Enclosure S: Sealed type Z: Dust cover 4Contact current 100A Terminals b: PCB type a: plug in type Coil rated voltage(V) DC:6,12,24 Contact material N:AgNi NIL: AgSnO2 Coil transient suppression: D: with diode.; 2D:with two diodes.;. R: with resistance.; DR: with diode and resistance; NIL: standard Contact Data Contact Arrangement Contact Material Contact Rating (resistive) Max. Switching Power Max. Switching Voltage Contact Resistance or Voltage drop 1A SPSTNO AgSnO 2 , AgNi 100A/14VDC 400W 75VDC 30m 10 5 10 7 Max. Switching Current:100A Item 3.12 of IEC255-7 Item 3.30 of IEC255-7 Item 3.31 of IEC255-7 Operation life Electrical Mechanical Coil Parameter Coil voltage VDC Coil resistance 10% Pick up voltage VDC(max) (55%of rated voltage) Release voltage VDC(min) (10% of rated voltage) Coil power consumption W Operate Time ms Release Time ms Dash numbers Rated Max. 012-10000 12 14.5 80 6.6 1.2 10 7 2 CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 2.Pickup and release voltage are for test purposes only and are not to be used as design criteria. JQ104E Operation condition Insulation Resistance1) Dielectric Strength Between contacts Between contact and coil Shock resistance Vibration resistance Terminals strength Solderability Ambient Temperature Relative Humidity Mass 1) 100M min (at 500VDC) Item 7 of IEC255-5 Item 6 of IEC255-5 Item 6 of IEC255-5 IEC68-2-27 Test Ea IEC68-2-6 Test Fc IEC68-2-21 Test Ua2 IEC68-2-20 Test Ta method 1 IEC68-2-3Test Ca 50Hz 1000V 50Hz 2000V 147m/s2 11ms 10~40Hz double amplitude 1.5mm 8N 4N PC type 235 2 3 0.5s -40~105 85% (at 40 ) 46g Note: 1). When testing, coil terminals should be connected, If coil transient suppression is installed in relay . Qualification inspection: Perform the qualification test as specified in the table of IEC255-19-1 and minimum sample size 24. Dimensions 5 mm /inch 36 Max. 0.630max. 0.197 1.12 0.044 0.276 ?7 50 1.969 39.5 1.555 1.375 35 3.433max. 87.2max. 77.4max. 0.393 1.118 0.669 12.8 17 10 0.504 44.4max. 1.748max. Dimensions Cover 1.575max. 0.791 0.346 0.201 0.024 1.375max. 0.031 0.268 0.118 Mounting (Bottom view) Wiring diagram (Bottom view) NOTES 1).Dimensions are in millimeters. 2).Inch equivalents are given for general information only. Ningbo Huaguan Relay Corporation LTD. 2.382max. 60.5max. 40 Max. 1.575max. 3.047max. 3 |
Price & Availability of JQ104EAZ100A
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |