ER3A ... ER3M ER3A ... ER3M Superfast Switching Surface Mount Si-Diodes Superschnelle Si-Dioden fur die Oberflachenmontage Version 2006-04-20 7.9 0.2 0.2 Nominal current Nennstrom 0.1 3A 50...1000 V ~ SMC ~ DO-214AB 0.21 g 1.2 0.15 Repetitive peak reverse voltage Periodische Spitzensperrspannung Plastic case Kunststoffgehause 2.2 2.1 5.8 Type Typ Weight approx. - Gewicht ca. Plastic material has UL classification 94V-0 Gehausematerial UL94V-0 klassifiziert Standard packaging taped and reeled Standard Lieferform gegurtet auf Rolle 0.2 7.5 0.2 Dimensions - Mae [mm] Maximum ratings Type Typ ER3A ER3B ER3D ER3G ER3J ER3K ER3M Repetitive peak reverse voltage Periodische Spitzensperrspannung VRRM [V] 50 100 200 400 600 800 1000 TT = 100C f > 15 Hz TA = 25C TA = 25C IFAV IFRM IFSM i2t 3 Grenzwerte Surge peak reverse voltage Stospitzensperrspannung VRSM [V] 50 100 200 400 600 800 1000 3A 15 A 1) 100 A 50 A2s -50...+150C -50...+150C Max. average forward rectified current, R-load Dauergrenzstrom in Einwegschaltung mit R-Last Repetitive peak forward current Periodischer Spitzenstrom Peak forward surge current, 50 Hz half sine-wave Stostrom fur eine 50 Hz Sinus-Halbwelle Rating for fusing, t < 10 ms Grenzlastintegral, t < 10 ms Junction temperature - Sperrschichttemperatur Storage temperature - Lagerungstemperatur TS Tj 1 Max. temperature of the terminals TT = 100C - Max. Temperatur der Anschlusse TT = 100C http://www.diotec.com/ (c) Diotec Semiconductor AG 1 ER3A ... ER3M Characteristics Type Typ ER3A...ER3D ER3G ER3J...ER3M Leakage current Sperrstrom Thermal resistance junction to ambient air Warmewiderstand Sperrschicht - umgebende Luft Thermal resistance junction to terminal Warmewiderstand Sperrschicht - Anschluss Reverse recovery time Sperrverzugszeit trr [ns] 1) < 35 < 35 < 75 Kennwerte Forward voltage Durchlass-Spannung VF [V] at / bei IF [A] < 1.0 < 1.25 < 1.7 Tj = 25C VR = VRRM Tj = 100C VR = VRRM IR IR RthA RthL 3 3 3 < 5 A < 300 A < 40 K/W 2) < 10 K/W 120 [%] 100 10 [A] 1 ER3A...D ER3G ER3J...M 80 60 0.1 40 10-2 20 IFAV 0 0 TT 50 100 150 [C] IF 10-3 Tj = 25C VF Forward characteristics (typical values) Durchlasskennlinien (typische Werte) [V] Rated forward current vs. temp. of the terminals Zul. Richtstrom in Abh. v. d. Temp. der Terminals 1 2 IF = 0.5 A through/uber IR = 1 A to/auf IR = 0.25 A Mounted on P.C. board with 50 mm2 copper pads at each terminal Montage auf Leiterplatte mit 50 mm2 Kupferbelag (Lotpad) an jedem Anschluss http://www.diotec.com/ (c) Diotec Semiconductor AG 2 |
Price & Availability of ER3B
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |