![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Presente / Presents: DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Quebec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com NHG RELAYS JQX- 102F 03001003507 R 30.5 16.0 23.5 30.5 16.0 26.5 Features R2133344 C US E158859 Can be welded directly onto PCB. Used in household appliances like air conditioning , heater and instruments etc. Ordering Information JQX-102F A 1 2 Z 20 3 4 b DC12V C 0.9 5 6 7 8 5 Terminal b:PC type NIL:PC type and QC type 6 Coil rated voltage(V) DC:5,12,24,48 7 Contact material C:AgCdO NIL:AgSnO2 8 Coil power consumption 0.9:0.9W 1 Part number JQX-102F 2 Contact arrangement A:1A 3 Enclosure Z: Dust cover 4 Contact rating Resistive:20A/250VAC Contact Data Contact Arrangement Contact Material Contact Rating( Resistive) Max. Switching Power Max. Switching Voltage Contact Resistance or Voltage drop Operation Electrical 1A SPSTNO AgSnO2 AgCd 20A/250VAC 5000VA 300VAC 30m (at 1A/14VDC) 105 Max. Switching Current:20A Item 3.12 of IEC255-7 Item 3.30 of IEC255-7 life Mechanical 2 106 Item 3.31 of IEC255-7 Coil Parameter Dash numbers Coil voltage VDC Rated 005-900 012-900 024-900 048-500 5 12 24 48 Max. 6 14.4 28.8 57.6 27.8 160 640 2560 Coil resistance 10% Pick up voltage VDC(max) (70% of rated voltage ) Release voltage VDC(min) (10% of rated voltage) 0.5 1.2 2.4 4.8 Coil power consumption W Operate Time ms Release Time ms 3.5 8.4 16.8 33.6 0.9 20 10 CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 2.Pickup and release voltage are for test purposes only and are not to be used as design criteria. JQX- 102F Operation condition Insulation Resistance Dielectric Strength Between contacts Between contact and coil Shock resistance Vibration resistance Terminals strength Solderability Ambient Temperature Relative Humidity Mass 1000M min (at 500VDC) Item 7 of IEC255-5 Item 6 of IEC255-5 Item 6 of IEC255-5 Item 8 of IEC255-5 IEC68-2-27 Test Ea IEC68-2-6 Test Fc IEC68-2-6 Test Fc IEC68-2-21 Test Ua1 and Ua2 IEC68-2-20 Test Ta method 1 IEC68-2-3Test Ca 50Hz 1500V 50Hz 4500V Surge voltage:10kV Functional:200m/s2 11ms Survival:1000 m/s2 11ms 10~55Hz double amplitude Functional 1.5mm double amplitude Survival 2.0mm 10N 8N 235 2 3 0.5s -25~70 85% (at 40 ) 23g Qualification inspection: Perform the qualification test as specified in the table of IEC255-19-1 and minimum sample size 24. TU V 20A/250VAC COS =0.9 CQC 20A/250VAC Safety approvals Safety approval Load UL&CUR 20A/250VAC Dimensions 16max. 0.630max. 6.4 0.252 4 3 10.2 8.3 0.402 0.327 18.4 0.724 6.3 0.248 mm /inch 30.5max. 1.201max. 26.5max. 1.043max. 3.2 0.126 9.4 0.370 1.8 0.071 3.4 0.138 2 0.079 10 0.394 6.2 0.244 23.5max. 0.925max. 8.0 0.244 3.5 0.138 8.4 0.331 0.5 0.020 1.4 0.055 0.8 0.031 2-1.5 0.3 0.059 0.012 1.8 0.071 2-1.5 0.8 0.059 0.031 0.3 0.012 16max. 0.630max. 3.5 0.138 1.4 0.055 2-1.5 0.3 0.059 0.012 30.5max. 1.201max. 0.8 0.031 0.5 0.020 1.8 0.071 2-1.5 0.8 0.059 0.031 0.3 0.012 Dimensions 1.8 12 0.472 0.071 27.6 1.087 1.4 0.055 16 0.630 NO 4 1 COM 3 2 4- 1.8 0.071 22 0.866 5.2 0.205 Mounting (Bottom view) NOTES 1).Dimensions are in millimeters. 2).Inch equivalents are given for general information only. Wiring diagram (Bottom view) Ningbo Huaguan Relay Corporation LTD. |
Price & Availability of JQX-102FAZ20BDC12C09
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |