  Datasheet File OCR Text:
 TFS 135C.doc
version 2.0
22.03.01
VI TELEFILTER
1. Measurement condition
Ambient temperature TA: Input power level: Terminating impedances at fc:
Filter Specification
TFS 135 C
1/5
23 C 0 dBm for input: for output:
50 -19,2 pF 50 -16,4 pF
2. Characteristics
Remark: Reference level for the relative attenuation arel of the TFS 135C is the insertion loss. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of the filter in the operating temperature range.
Data Insertion loss (Reference level) Centre frequency Relative attenuation fc fc fc 1,25 MHz 4 15 MHz MHz fc 15 MHz fc 25 MHz fc 1,0 MHz ae fc arel
typ. value 14,6 dB
tolerance / limit max 15,5 dB kHz
135,420 MHz 60
45...48 50...60 dB dB
max min min
3 40 38
dB dB dB
Group delay ripple:
80
ns
Temperature coefficient of frequency ( Tcf ) Frequency deviation of fc over temperature T: Operating Temperature Range
-19
ppm/K
fc(Hz) = Tcf(ppm/K) x (T - TA) x fCAT (MHz) - 10 C ... + 85 C
Generated:
_____________
Checked/Approved:
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
TFS 135C.doc
version 2.0
22.03.01
VI TELEFILTER
Filter Specification
TFS 135 C
2/5
3. Construction, pin configuration and 50 - matching network
(All dimensions in mm) Datecode L M N ... Year+week 1999 2000 2001
N06 S 135C
1 2 3 4 5 6 7 8 9 10 11 12
Ground Ground Output Ground Ground Ground Ground Ground Input Ground Ground Ground
50 test circuit
9
3
IN
L1
SAW
L2
OUT
1,2,4,5,6,7,8,10,11,12
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
TFS 135C.doc
version 2.0
22.03.01
VI TELEFILTER
Filter Specification
TFS 135 C
3/5
4. Stability characteristics
After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Damp heat: (cycle) 4. Resistance to solder heat (reflow): 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 25 C to 55C / 95% r.H. / 10 cycles DIN IEC 68 - 2 - 30 Db max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
5. Packing
Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: Reel of empty components at start: Reel of empty components at start including leader: Trailer 2000 min 300 mm min 500 mm min 300 mm
Tape (all dimensions in mm) W Po Do E F P2 P1 Ao Bo CT : : : : : : : : : : 16 4 0,3 0,1
Do Po
EMBOSSED CARRIER TAPE
P2
1,5 + 0,1 1,75 0,1
Ao E
7,5 0,1 0,6 2 8 1,5 5,5 7,5 0,1 0,1
COVER TAPE P1 D1 CT F W
G (min) :
0,1 0,1
Bo
D1(min) :
G
13,5 + 0,1
W2
Reel (all dimensions in mm): A W1 N (min) C : : : : 330 16,4 +2 22,4 50 13 +0,5 / -0,2
A C N
W2 (max) :
W1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is readable if the sprocket holes are on the left side of the tape, i.e. pin 1 identifier is close to the sprocket holes.
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
TFS 135C.doc
version 2.0
22.03.01
VI TELEFILTER
6. Air reflow temperature conditions
Filter Specification
TFS 135 C
4/5
1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 C - 170 main-heating periods Cover 200 C 60 sec. - 90 sec. peak temperature 255 C 5 C 20 sec. - 25 sec.
Air reflow profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 140 160 180 200 220 240
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
TFS 135C.doc
version 2.0
22.03.01
VI TELEFILTER
Filter Specification
TFS 135 C
5/5
7. History Version Reason of Changes Name Date
1.0 2.0
- generate specification
Pfeiffer
09.02.01 22.03.01
- new definition of insertion loss (minimum of the passband attenuation) Pfeiffer - new teminating impedances at fC - fC = 135,420 MHz 60 kHz - change from nominal frequency to centre frequency as basis for relative attenuation - ae = 15,5 dB - group delay ripple = 80 ns
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information


▲Up To Search▲   

 
Price & Availability of TFS135C

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X