|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
TOTAL POWER INT'L 40W Triple Output Switching Power Supply Features : Universal AC input / Full range Cooling by free air convection 100% full load burn-in test Fixed switching frequency at 40KHz 2 years warranty T- 4 0 series Protections:Short circuit/Over load/Over voltage SPECIFICATION MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT T-40A 5V 3A 0.6 ~ 5A 41.5W 100mVp-p 8.0% 1.0% 6.0% T-40B 12V 2A 0.2 ~ 3A -5V 0.5A 0.1 ~ 1A 5V 3A 0.6 ~ 5A 45W 100mVp-p 120mVp-p 120mVp-p 8.0% 1.0% 6.0% T-40C 12V 2A 0.2 ~ 3A -12V 0.5A 0.1 ~ 1A 5V 3A 0.6 ~ 5A 45W 100mVp-p 2.0% 0.5% 0.5% 15V 1.5A 0.2 ~ 2A 120mVp-p 6.0% 1.0% 4.0% -15V 0.5A 0.1 ~ 1A 120mVp-p 6.0% 1.0% 4.0% 120mVp-p RIPPLE & NOISE (max.) Note.2 100mVp-p VOLTAGE ADJ. RANGE CH1 : 4.75 ~ 5.5V 6.0% VOLTAGE TOLERANCE Note.3 2.0% LINE REGULATION LOAD REGULATION SETUP, RISE, HOLD TIME VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY(Typ.) AC CURRENT INRUSH CURRENT(max.) LEAKAGE CURRENT OVER LOAD 0.5% 0.5% 85 ~ 264VAC 47 ~ 63Hz 72%/115VAC CH1 : 4.75 ~ 5.5V 2.0% 6.0% 0.5% 0.5% 1.0% 4.0% CH1 : 4.75 ~ 5.5V 1.0% 4.0% 800ms, 50ms, 60ms/230VAC 120 ~ 370VDC 1.6s, 50ms,16ms/115VAC at full load INPUT 72%/115VAC 72%/115VAC 1.2A/115VAC 0.7A/230VAC COLD START 20A/115VAC 40A/230VAC <3.5mA / 240VAC 105 ~ 150%/115VAC of rate load Protection type : Hiccup mode, recovers automatically after fault condition is removed 5V: 5.75 ~ 6.75V Protection type : Hiccup mode, recovers automatically after fault condition is removed -10 ~ +60 -20 ~ +85 PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE (Refer to output load derating curve) , 10 ~ 95% RH 20 ~ 90% RH non-condensing 0.03%/ (0 ~ 50 )on +5V output 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes CSA 950, (UL1950, IEC950, TUV EN60950) Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B EMC (Note 4) HARMONIC CURRENT EMS IMMUNITY MTBF DIMENSION PACKING Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, Light industry level, criteria A 305.6K hrs min. MIL-HDBK-217F (25 129*98*38mm (L*W*H) 0.45Kg; 30pcs/13.5Kg/0.86CUFT ) OTHERS NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 40W Triple Output Switching Power Supply Mechanical Specification 4.5 T- 4 0 Case No. 903 series Unit:mm 122.5 1 9.5 2 3 5 8.2 6 7 3 .5 4.5 73.5 129 6.5 120 9 .5 9 1 8 .5 3 .5 9 3 7 .5 3 -M 3 32 77 Terminal Pin. No Assignment Pin No. 1 2 3 Assignment AC/L AC/N FG Pin No. 4 5 6 Assignment DC OUTPUT -V DC OUTPUT +V2 DC OUTPUT COM Pin No. 7 Assignment DC OUTPUT +V1 Output Derating Static Characteristics (B) Ta=25 100 13 12 11 10 9 8 7 18 9 7 .7 5 4 2- M 3 33 31 3 .5 8 5 .5 7 3 .5 5.2 300 250 OUTPUT VOLTAGE (V) 5.0 4.8 4.6 4.4 4.2 4.0 80 +5V +12V 200 150 100 60 40 20 +12V +5V -12V 50 25 -10 0 10 20 30 40 50 45 60 55 (VERTICAL) (HORIZONTAL) 60 80 100 120 140 160 180 200 220 240 260 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz OUTPUT RIPPLE (mVp-p) -12V LOAD (%) |
Price & Availability of T-40C |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |