SR037DB1 Inductorless Switching Power Supply Introduction The Supertex SR037 is an inductorless switching power supply controller intended for 120/240VAC line operation. The operating principle is to activate a pass element between line and load only when the input voltage is lower than a certain value. Thus conduction only occurs with a low voltage drop across the pass element, resulting in more efficient operation compared to a standard linear regulator. The SR037DB1 demo board contains all the circuitry needed to supply a low-current (<40mA) load. Included is input protection circuitry, a full wave bridge rectifier, a pass element, and output capacitors. Specifications AC Input Output Voltages VUNREG VREG Output Current IUNREG + IREG Efficiency ACIN=120VAC 60Hz, IU=40mA, IR=0mA 24VAC to 264VAC 40Hz to 100Hz 12V to 22V 5.0V 10% 40mA @120VAC 30mA @ 240VAC 40% typ Board Layout and Connections Q1 Z1 ACIN F1 D1 IC1 C2 C1 GND WARNING!!! Do not connect to scope ground or to the ground of other earth-grounded instruments. Doing so will short the AC line, resulting in damage to the circuit and/or instrument. Either use an isolation transformer on the AC line, use a differential probe, or use a floating, battery-powered instrument to make measurements. VREG VUNREG WARNING!!! No galvanic isolation. Dangerous voltages are present when connected to the AC mains. ACIN Connect to the AC line. The AC input is protected by a 400V transient voltage suppressor and a 250mA fuse. GND Circuit common. Note that since galvanic isolation is not provided, connecting this point to an earth-grounded instrument (such as an oscilliscope) will short the AC line, resulting in circuit and/or instrument damage. Also note that GND may be at a higher potential with respect to earth ground, even if the AC is switched off. Use caution! Do not connect to earth ground. This ground must remain floating when supplied from the AC line! VUNREG The unregulated output. Nominal output voltage is 18 volts. This output will have a certain amount of 120Hz ripple, depending on load. Do not connect to earth-grounded loads. VREG The regulated output. 5.0V nominal output voltage. Do not connect to earth-grounded loads. 22MAR02 1 SR037DB1 Inductorless Switching Power Supply SR037 Schematic 250mA 120/240VAC 50/60Hz P6KE400CA VN2460 VUNREG 220DF SR037 1DF VREG Parts List Desig F1 Z1 D1 IC1 Q1 C1 C2 Desc Fuse, 3AG, 250mA, 250V Transient voltage suppressor, 400V Diode bridge, 1A, 600V HV Supply Controller MOSFET, 600V N-channel Capacitor,alum, 220DF, 35V Capacitor, cer, 1DF, 16V Part Number P6KE400CA Supertex SR037SG Supertex VN2460N8 Modifications The SR037DB1 may be modified to provide higher output current. Remove Q1 and replace with a D-Pak N-channel MOSFET with a voltage rating appropriate for the input voltage. The on resistance of the replacement FET is not as important as the gate threshold voltage - the lower the threshold voltage, the more efficient the converter. To reduce ripple at the higher output current, C1 may be replaced with a higher value capacitor. 22MAR02 2 |
Price & Availability of SR037DB1
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |