|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
MDU13H TRIPLE, ECL-INTERFACED FIXED DELAY LINE (SERIES MDU13H) FEATURES * * * * Three independent delay lines Fits standard 16-pin DIP socket Auto-insertable Input & outputs fully 10KH-ECL interfaced & buffered GND 1 16 15 14 13 I1 I2 I3 VEE 5 6 7 8 O1 O2 O3 data 3 (R) delay devices, inc. PACKAGES GND GND N/C N/C N/C I1 I2 I3 VEE 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 GND O1 O2 O3 N/C N/C N/C N/C MDU13H-xx DIP MDU13H-xxM Military DIP MDU13H-xxC3 SMD MDU13H-xxMC3 Mil SMD FUNCTIONAL DESCRIPTION The MDU13H-series device is a 3-in-1 digitally buffered delay line. The signal inputs (I1-I3) are reproduced at the outputs (O1-O3), shifted in time by an amount determined by the device dash number (See Table). The delay lines function completely independently of each other. PIN DESCRIPTIONS I1-I3 O1-O3 VEE GND Signal Inputs Signal Outputs -5 Volts Ground SERIES SPECIFICATIONS * * * * * * Minimum input pulse width: 50% of total delay Output rise time: 2ns typical Supply voltage: -5VDC 5% Power dissipation: 200mw typical (no load) Operating temperature: -30 to 85 C Temp. coefficient of total delay: 100 PPM/C DASH NUMBER SPECIFICATIONS Part Number MDU13H-3 MDU13H-4 MDU13H-5 MDU13H-10 MDU13H-15 MDU13H-20 MDU13H-25 MDU13H-30 MDU13H-35 MDU13H-40 MDU13H-45 MDU13H-50 Delay Per Line (ns) 3 1.0 4 1.0 5 1.0 10 1.0 15 1.0 20 1.0 25 2.0 30 2.0 35 2.0 40 2.0 45 2.2 50 2.5 O1 O2 O3 100% 100% 100% * Total delay is referenced to first tap output Input to first tap = 1.5ns 1ns NOTE: Any dash number between 3 and 50 not shown is also available. VCC I1 I2 I3 GND Functional block diagram (c)1997 Data Delay Devices Doc #97037 12/11/97 DATA DELAY DEVICES, INC. 3 Mt. Prospect Ave. Clifton, NJ 07013 1 MDU13H APPLICATION NOTES HIGH FREQUENCY RESPONSE The MDU13H tolerances are guaranteed for input pulse widths and periods greater than those specified in the test conditions. Although the device will function properly for pulse widths as small as 50% of the total delay and periods as small as 100% of the total delay (for a symmetric input), the delays may deviate from their values at low frequency. However, for a given input condition, the deviation will be repeatable from pulse to pulse. Contact technical support at Data Delay Devices if your application requires device testing at a specific input condition. POWER SUPPLY BYPASSING The MDU13H relies on a stable power supply to produce repeatable delays within the stated tolerances. A 0.1uf capacitor from VEE to GND, located as close as possible to the VEE pin, is recommended. A wide VEE trace and a clean ground plane should be used. DEVICE SPECIFICATIONS TABLE 1: ABSOLUTE MAXIMUM RATINGS PARAMETER DC Supply Voltage Input Pin Voltage Storage Temperature Lead Temperature SYMBOL VEE VIN TSTRG TLEAD MIN -7.0 VEE - 0.3 -55 MAX 0.3 0.3 150 300 UNITS V V C C NOTES 10 sec TABLE 2: DC ELECTRICAL CHARACTERISTICS (0C to 75C) PARAMETER High Level Output Voltage Low Level Output Voltage High Level Input Voltage Low Level Input Voltage High Level Input Current Low Level Input Current SYMBOL VOH VOL VIH VIL IIH IIL MIN -1.020 -1.950 -1.480 475 0.5 TYP MAX -0.735 -1.600 -1.070 UNITS V V V V A A NOTES VIH = MAX,50 to -2V VIL = MIN, 50 to -2V VIH = MAX VIL = MIN Doc #97037 12/11/97 DATA DELAY DEVICES, INC. Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com 2 MDU13H PACKAGE DIMENSIONS 16 15 14 13 .400 TYP. 1 5 6 7 8 .800 TYP. .020 .320 TYP. MAX. .150 .030 .018 TYP. .700 TYP. .100 TYP. .010 TYP. .300 TYP. MDU13H-xx (Commercial DIP) MDU13H-xxM (Military DIP) .020 TYP. 16 15 14 13 12 11 10 9 .040 TYP. .010.002 .710 .590 .005 MAX. .882 .005 .007 .005 1 2 3 4 5 6 7 8 .090 .700 .880.020 .100 .280 MAX. .050 .010 MDU13H-xxC3 (Commercial SMD) MDU13H-xxMC3 (Military SMD) Doc #97037 12/11/97 DATA DELAY DEVICES, INC. 3 Mt. Prospect Ave. Clifton, NJ 07013 3 MDU13H DELAY LINE AUTOMATED TESTING TEST CONDITIONS INPUT: Ambient Temperature: 25oC 3oC Supply Voltage (Vcc): -5.0V 0.1V Input Pulse: Standard 10KH ECL levels Source Impedance: 50 Max. Rise/Fall Time: 2.0 ns Max. (measured between 20% and 80%) Pulse Width: PWIN = 1.5 x Total Delay Period: PERIN = 10 x Total Delay OUTPUT: Load: Cload: Threshold: 50 to -2V 5pf 10% (VOH + VOL) / 2 (Rising & Falling) NOTE: The above conditions are for test only and do not in any way restrict the operation of the device. REF PULSE GENERATOR OUT TRIG I1 I2 I3 DEVICE UNDER TEST (DUT) O1 O2 O3 IN TRIG OSCILLOSCOPE Test Setup PERIN PWIN TRISE INPUT SIGNAL 80% 50% 20% TFALL VIH 80% 50% 20% VIL TFALL TRISE OUTPUT SIGNAL VOH 50% 50% VOL Timing Diagram For Testing Doc #97037 12/11/97 DATA DELAY DEVICES, INC. Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com 4 |
Price & Availability of MDU13H-5MC3 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |