60 Watts LPT60 Series Total Power: Input Voltage: # of Outputs: 60-80 Watts 85-264 VAC 120-300 VDC Triple Electrical Specs Input Input range Frequency Inrush current 85-264 VAC 120-300 VDC 47-440 Hz <18 A peak @ 115 VAC; <36 A peak @ 230 VAC, cold start @ 25C 1.5 A max. (RMS) @ 115 VAC 70% typical at full load (60% for LPT61) FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted <0.5 mA @ 50/60 Hz, 264 VAC input Input current Efficiency EMI filter Special Features * * * * * * * * * * Universal input 3" x 5" footprint Remote sense on main output Built-in EMI filter Low output ripple Adjustable main output Overvoltage protection Overload protection 110 KHz switching frequency LPX60 enclosure kit available Safety ground leakage current Output Maximum power 60 W for convection (LPT61, 35 W); 80 W with 30 CFM forced air (LPT61, 55 W) -5, +10% minimum 2% on output 1; 5% on outputs 2,3 20 ms @ 60 W load, 115 VAC nominal line Short circuit protection on all outputs. Case overload protected @ 110-145% above peak rating 5.7-6.7 VDC on main output LPT61: 3.6 to 4.6 VDC Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Adjustment range Cross regulation Hold-up time Overload protection Environmental Overvoltage protection Operating temperature: 0 to 50C ambient derate each output at 2.5% per degree from 50 to 70C Electromagnetic susceptibility: designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Humidity: Operating; non-condensing 5% to 95% Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5 Hz to 500 Hz, operational Storage temperature: -40 to 85C Temperature coefficient: .04% per C MTBF demonstrated: >550,000 hours at full load and 25C ambient conditions VDE UL CSA NEMKO BABT CB CE Remote sense Safety 0805/EN60950 (IEC950) UL1950 CSA 22.2-234 Level 3 EN 60950/EMKO-TUE (74-sec) 203 EN60950/BS7002 Certificate and report Mark (LVD) 11774-3336-1255 (LC #86665) E132002 LR53982C P95100123 PS / 605273 1518, 1519, 1520 96 America's (USA): 1-888-41-ASTEC Europe (UK): 44 (1384) 842-211 Asia (HK): 852-2437-9662 rev 12.01.01 AMERICAS 5810 Van Allen Way Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698 EUROPE Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 44 (1384) 842-211 Facsimile: 44(1384) 843-355 ASIA Units 2111-2116, Level 21 Tower1, Metroplaza 223, Hing Fong Road Fwai Fong, New Territories Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426 LPT60 Series Ordering Information Model Number LPT61 Output Voltage +3.3 V +5 V +12 V +5 V +12 V -12 V +5 V +15 V -15 V +5 V +12 V -5 V +5 V +24 V +12 V +5 V +24 V -12 V +5 V +24 V -5 V Minimum Load 0.7A 0A 0A 0.7 A 0.3 A 0A 0.7 A 0.3 A 0A 0.7 A 0.3 A 0A 0.7 A 0.1 A 0A 0.7 A 0.1 A 0A 0.7 A 0.1 A 0A Maximum Load with Convection Cooling 5A 2.5 A 0.5 A 7A 3A 0.7 A 7A 2.8 A 0.7 A 7A 3A 0.7 A 7A 1.5 A 0.7 A 7A 1.5 A 0.7 A 7A 1.5 A 0.7 A Maximum Load with 30 CFM Forced Air 8.5 A 3.0 A 1.0 A 8A 3.5 A 1A 8A 3.3 A 1A 8A 3.5 A 1A 8A 2.0 A 1A 8A 2.0 A 1A 8A 2.0 A 1A Peak Load1 9.5 A 3.3 A 1A 10 A 6A 1.5 A 10 A 4A 1.5 A 10 A 6A 1.5 A 10 A 3A 1.5 A 10 A 3A 1.5 A 10 A 3A 1.5 A Regulation2 Ripple P/P (PARD)3 50mV 50mV 120mV 50 mV 120 mV 120 mV 50 mV 150 mV 150 mV 50 mV 120 mV 50 mV 50 mV 240 mV 120 mV 50 mV 240 mV 120 mV 50 mV 240 mV 50 mV 2% 2% 5% 2% 5% 5% 2% 5% 5% 2% 5% 5% 2% 7% 5% 2% 7% 5% 2% 7% 5% LPT62 LPT63 LPT64 LPT65 LPT66 LPT67 1. 2. 3. 4. Peak current lasting <30 seconds with a maximum 10% duty cycle. At 25C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. Peak-to-peak with 20 MHz bandwidth and 10 F in parallel with a 0.1 F capacitor at rated line voltage and load ranges. Minimum Loads are required. Power Derating Curve Pin Assignments Connector SK1-1 SK1-3 SK2-1 SK2-2 SK2-3 SK2-4 SK2-5 SK2-6 SK201-1 SK201-2 LPT61 Neutral Line LPT62 Neutral Line LPT63 Neutral Line +15 V +5 V +5 V Common Common -15 V +Sense -Sense LPT64 Neutral Line +12 V +5 V +5 V Common Common -5 V +Sense -Sense LPT65 Neutral Line +24V +5 V +5 V Common Common +12 V +Sense -Sense LPT66 Neutral Line +24V +5 V +5 V Common Common -12 V +Sense -Sense LPT67 Neutral Line +24V +5 V +5 V Common Common -5 V +Sense -Sense 80W 30 CFM Forced Air Cooling 60W Output Power (Watts) 40W 20W 0W Natural Convection Cooling 40W 30W 5V +12 V 3.3 V +5 V 3.3 V +5 V Common Common Common Common +12V -12 V +Sense +Sense -Sense -Sense 0C 10C 20C 30C 40C 50C 60C 70C TA - Ambient Temperature - C 5.00" (127) 0.22" (5.6) M1 GND 4.55" (115.6) SK201 + _ M2 Mating Connectors AC Input: Molex 09-50-8031 (USA) 09-91-0300 (UK) PINS: 08-58-0111 DC Outputs: Molex 09-50-8061 (USA) 09-91-0600 (UK) PINS: 08-58-0111 Remote Sense: Molex 22-01-2025 PINS: 08-50-0114 Astec Connector Kit #70-841-006, includes all of the above. Notes: 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is .02". 3. Mounting holes M1 and M2 should be grounded for EMI purposes. 4. Mounting hole M1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 VAC input, 25C unless otherwise stated. 6. Warranty: 1 year 7. Weight: 0.75 lb. / 0.34 kg 3.00" (76.2) 2.55" (64.8) 1 3 SK 1 Remote Sense Connector Voltage Adj. Pot N L 1 2 3 4 5 6 SK 2 0.15" (4) DIA (4 places) 1.65" (41.9) 0.12" (3) www.astec.com 97 |
Price & Availability of LPT67
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |