![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Bulletin PD-20013 Rev.B 10/03 IRUD360CW40 FRED Features Ultrafast Recovery 150C Operating Junction Temperature Benefits Reduced RFI and EMI Higher Frequency Operation Reduced Snubbing Reduced Parts Count LUG TERMINAL ANODE 1 LUG TERMINAL ANODE 2 Ultrafast, Soft Recovery Diode VR = 400V VF(typ.) = 1.23V BASE COMMON CATHODE IF(AV) = 350A Description/ Applications These diodes are optimized to reduce losses and EMI/ RFI in high frequency power conditioning systems. The softness of the recovery eliminates the need for a snubber in most applications. These devices are ideally suited for HF welding, power converters and other applications where switching losses are not a significant portion of the total losses. Absolute Maximum Ratings Parameters (*) VR IF(AV) @ TC = 25C IF(AV) @ TC = 110C IFSM PD @ TC = 25C PD @ TC = 110C Cathode-to-Anode Voltage Continuous Forward Current Continuous Forward Current Single Pulse Forward Current Maximum Power Dissipation Maximum Power Dissipation Max 400 350 190 1200 570 180 Units V A W Case Styles IRUD360CW40 TO-244 (*) Per Leg unless otherwise specified 1 IRUD360CW40 Bulletin PD-20013 Rev.B 10/03 Electrical Characteristics (per Leg) @ TJ = 25C (unless otherwise specified) Parameters VBR VFM Breakdown Voltage, Forward Voltage Min Typ Max Units Test Conditions 400 V IR = 100A IF = 180A IF = 360A IF = 180A @ TJ = 150C IF = 360A @ TJ = 150C A mA nH VR = VR Rated TJ = 150C, VR = VR Rated from top of terminal hole to mounting plane 1.09 1.27 1.23 1.50 0.88 0.96 1.04 1.18 65 IRM Reverse Leakage Current - 0.26 1.28 5 - LS Series Inductance - Dynamic Recovery Characteristics @ TJ = 25C (unless otherwise specified) Parameters trr Reverse Recovery Time Min Typ Max Units Test Conditions 42 74 171 5.1 6.6 15.2 126 243 1295 69 nC A ns If = 1.0A, dif/dt = 200A/s, Vr = 30V If = 180A, dif/dt = 200A/s, Vr = 200V If = 180A, dif/dt =200A/s, Vr =200V @ TJ = 125C If = 1.0A, dif/dt = 200A/s, Vr = 30V If = 180A, dif/dt = 200A/s, Vr = 200V If = 180A, dif/dt =200A/s, Vr =200V @ TJ = 125C If = 1.0A, dif/dt = 200A/s, Vr = 30V If = 180A, dif/dt = 200A/s, Vr = 200V If = 180A, dif/dt =200A/s, Vr =200V @ TJ = 125C IRRM Peak Recovery Current - Qrr Reverse Recovery Charge - Thermal - Mechanical Characteristics Parameters TJ TStg RthJC RthCS Wt T Max. Junction Temperature Range Max. Storage Temperature Range Thermal Resistance, Junction to Case Thermal Resistance, Junction to Case Thermal Resistance, Case to Heatsink flat greased surface Weight Mounting Torque Mounting Torque Center Hole Terminal Torque Vertical Pull 2 inch. Lever Pull 30 (3.4) 12 (1.4) 30 (3.4) 68 (2.4) 40 (4.6) 18 (2.1) 40 (4.6) 80 35 lbf.in g (oz) lbf.in (N.m) Per Leg Per Module Min - 40 - 40 - Typ 0.10 Max 150 150 0.22 0.11 - Units C C/W 2 IRUD360CW40 Bulletin PD-20013 Rev.B 10/03 1000 Reverse Current - IR (A) Tj = 150C 100 1000 10 1 25C Instantaneous Forward Current - IF (A) 0.1 0 100 100 200 300 Reverse Voltage - VR (V) 400 Fig. 2 - Typical Reverse Current vs. Reverse Voltage (per Leg) 150 Average Power Loss (W) IRUD360CW40 RthJC = 0.24 K/W 10 Tj = 150C Tj = 25C 140 130 120 110 DC D = 0.5 1 0 0.5 1 1.5 2 Forward Voltage Drop - VFM (V) Fig. 1 - Typical Forward Voltage Drop vs. Instantaneous Forward Current (per Leg) 100 0 50 100 150 200 Current Rating - IDC (A) Fig. 3 - Max. Current Rating Capability (per Module) 3 IRUD360CW40 Bulletin PD-20013 Rev.B 10/03 240 200 RMS Limit 360A 180A 90A Forward Power Loss (W) 220 150 DC tRR (ns) 200 100 180 160 50 D = 0.01 D = 0.02 D = 0.05 D = 0.10 D = 0.20 D = 0.50 140 100 200 300 400 500 0 0 50 100 150 200 dif/dt (A/us) Forward Current (A) Fig. 4 - Typical Reverse Recovery vs. dif /dt Tj = 125C (per Leg) Fig. 5 - Forward Power Loss Characteristics Reverse Recovery Circuit VR = 200V 0.01 L = 70H D.U.T. di F /dt dif/dt ADJUST D G IRFP250 S Fig. 6- Reverse Recovery Parameter Test Circuit 4 IRUD360CW40 Bulletin PD-20013 Rev.B 10/03 3 IF 0 trr ta tb 4 Q rr 2 I RRM 0.5 I RRM di(rec)M/dt 0.75 I RRM 5 1 di /dt di fF/dt 1. diF/dt - Rate of change of current through zero crossing 2. IRRM - Peak reverse recovery current 3. trr - Reverse recovery time measured from zero crossing point of negative going IF to point where a line passing through 0.75 IRRM and 0.50 IRRM extrapolated to zero current 4. Qrr - Area under curve defined by t rr and IRRM t rr x I RRM Q rr = 2 5. di (rec) M / dt - Peak rate of change of current during t b portion of t rr Fig. 7 - Reverse Recovery Waveform and Definitions 5 IRUD360CW40 Bulletin PD-20013 Rev.B 10/03 Outline Table Conforms to JEDEC Outline TO-244 Dimensions in millimeters and (inches) Ordering Information Table Device Code IR 1 UD 2 360 3 C 4 W 5 40 6 1 2 3 4 5 6 - International Rectifier Type of Device Indicator: Current Rating indicator x1 : Circuit Configuration Indicator: Type of Device Indicator: Voltage Rating indicator x10 : UD = HEXFRED Gen.2 360 = 360A C = Common Cathode W = TO-244 Wire Bondable Not Isolated 40 = 400V Data and specifications subject to change without notice. This product has been designed and qualified for Industrial Level. Qualification Standards can be found on IR's Web site. IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105 TAC Fax: (310) 252-7309 Visit us at www.irf.com for sales contact information. 10/02 6 |
Price & Availability of IRUD360CW40
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |