![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Solid-state Relay PCB-mounting SSR for FA Equipment Requiring High Reliability Wide I/O voltage range: 3 to 28 VDC input and 75 to 264 VAC output or 3 to 28 VDC input and 3 to 52.8 VDC output. Two load currents available: 2 A and 3 A Flat and vertical models available for a variety of applications. Approved by UL and CSA. G3CN RC Ordering Information Isolation Photocoupler Zero cross function Yes Indicator No Rated output voltage (Applicable output load) 2 A at 100 to 240 VAC (2 A at 75 to 264 VAC) 3 A at 100 to 240 VAC (3 A at 75 to 264 VAC) Phototriac No 2 A at 100 to 240 VAC (2 A at 75 to 264 VAC) 3 A at 100 to 240 VAC (3 A at 75 to 264 VAC) Photocoupler --2 A at 4 to 48 VDC (2 A at 3 to 52.8 VDC) 3 A at 4 to 48 VDC (3 A at 3 to 52.8 VDC) *Vertical models. **When ordering, specify the input voltage 4 to 24 VDC 5, 12, 24 VDC** Rated input voltage 4 to 24 VDC Model G3CN-202P-US G3CN-202P1-US* G3CN-203P-US G3CN-203P1-US* G3CN-202PL-US G3CN-202PL1-US* G3CN-203PL-US G3CN-203PL1-US* G3CN-DX02P-US G3CN-DX02P1-US* G3CN-DX03P-US G3CN-DX03P1-US* 171 G3CN G3CN Specifications Ratings Input Model Rated voltage Operating voltage Impedance Voltage level Must operate voltage G3CN-202P(1)-US G3CN-203P(1)-US G3CN-202PL(1)-US G3C 0 ( ) US G3CN 203PL(1) US G3CN-203PL(1)-US 4 to 24 VDC 5 VDC 12 VDC 24 VDC G3CN-DX02P(1)-US G3CN-DX03P(1)-US Note: 4 to 24 VDC 3 to 28 VDC 4 to 6 VDC 9.6 to 14.4 VDC 19.2 to 28.8 VDC 3 to 28 VDC 1.5 k +20%/-10% 390 20% 900 20% 2 k20% 1.5 k +20%/-10% 3 VDC max. 4 VDC max. 9.6 VDC max. 19.2 VDC max. 3 VDC max. Must release voltage 1 VDC min. The input impedance is measured at the maximum value of the operating voltage. For example, with the model rated at 4 to 24 VDC, the input impedance is measured at 28 VDC. Output Model Rated load voltage G3CN-202P(1)-US G3CN-202PL(1)-US G3CN-203P(1)-US G3CN-203PL(1)-US G3CN-DX02P(1)-US G3CN-DX03P(1)-US 4 to 48 VDC 3 to 52.8 VDC 100 to 240 VAC Applicable load Load volage range 75 to 264 VAC Load current Without heat sink 0.1 to 2 A 0.1 to 3 A 0.1 to 2 A 0.1 to 3 A 30 A (60 Hz, 1 cycle) 45 A (60 Hz, 1 cycle) 12 A (10 ms) 18 A (10 ms) Inrush current Characteristics Item Operate time Release time Output ON voltage drop Leakage current Insulation resistance Dielectric strength Vibration resistance Shock resistance Ambient temperature Ambient humidity Approved standards Weight G3CN-202P(1)/203P(1)-US 1/2 of load power source cycle + 1 ms max. 1/2 of load power source cycle + 1 ms max. 1.6 V (RMS) max. 5 mA max. (at 100 VAC) 10 mA max. (at 200 VAC) 100 M min. (at 500 VDC) 2,500 VAC, 50/60 Hz for 1 min Malfunction: 10 to 55 Hz, 1.5-mm double amplitude Malfunction: 1,000 m/s2 Operating: -30C to 80C (with no icing nor condensation) Storage: -30C to 100C (with no icing nor condensation) Operating: 45% to 85% UL508, UL114 File No.E64562, CSA C22.2 (No.0, No.14) File No. LR35535 Approx. 25 g 2.5 mA max. (at 100 VAC) 5 mA max. (at 200 VAC) G3CN-202PL(1)/203PL(1)-US 1 ms max. 1/2 of load power source cycle + 1 ms max. G3CN-DX02P(1)/03P(1)-US 0.5 ms max. 2 ms max. 1.5 V max. 5 mA max. (at 50 VDC) 172 G3CN G3CN Engineering Data Load Current vs. Ambient Temperature Characteristics G3CN-202P(1)/-202PL(1)/-DX02P(1)-US G3CN-203P(1)/-203PL(1)/-DX03P(1)-US Load current (A) Ambient temperature (C) Load current (A) Ambient temperature (C) Inrush Current Resistivity Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.) G3CN-202P(1)/-202PL(1)-US G3CN-DX02P(1)-US Inrush current (A. Peak) Energizing time (ms) Inrush current (A. Peak) Energizing time (ms) G3CN-203P(1)/-203PL(1)-US G3CN-DX03P(1)-US Inrush current (A. Peak) Energizing time (ms) Inrush current (A. Peak) Energizing time (ms) 173 G3CN G3CN Dimensions Note: All units are in millimeters unless otherwise indicated. Flat Model G3CN-20jP/-20jPL/-DX0jP 33 max. 25 max. Terminal Arrangement/ Mounting Holes (Bottom View) Four 1.2-dia. holes 25 Two, 4 dia. holes 10 14.5 20 max. max. 1.5 max. Two, 2-dia. holes 0.4 250.5 0.7 100.5 12.50.5 + Input voltage - 3 + Input - 4 Load (-) 2 0.7 12.5 Terminal Arrangement/ Internal Connections (Bottom View) 1 (+) Load power supply (-) Load (+) Vertical Model G3CN-20jP1/-20jPL1/-DX0jP1 33 max. Note: Values in parentheses apply to the DC-load versions. 14 max. Terminal Arrangement/ Mounting Holes (Bottom View) Two, 2-dia. holes Four 1.2-dia. holes Pattern 5 26.5 max. 32 max. 1.5 max. (17.5) 27.5 5 Pattern Terminal Arrangement/ Internal Connections (Bottom View) (17.5) 27.50.5 0.7 50.5 0.4 31 Input voltage - + Load power supply (-) (+) Load 50.5 4 - 3 + Input (-) 21 (+) Load Note: Values in parentheses apply to the DC-load versions. 174 G3CN G3CN Precautions Refer to pages 11 to 19 for general precautions. Connection With the SSR for DC switching, the load can be connected to either positive or negative output terminal of the SSR. Protective Component Since the SSR does not incorporate an overvoltage absorption component, be sure to connect an overvoltage absorption component when using the SSR under an inductive load. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. K063-E1-2A 175 |
Price & Availability of G3CN-DX03P1-US
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |