TOTAL POWER INT'L 75W Single Output Industrial DIN Rail Power Supply Features : Universal AC input/Full range Protections:Short circuit/Over load/Over voltage/Over temperature Cooling by free air convection Can be installed on DIN rail TS-35/7.5 or 15 UL 508(industrial control equipment)approved LED indicator for power on 100% full load burn-in test Fix switching frequency at 50KHz 3 years warranty DR-75 series R SPECIFICATION MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT DR-75-12 12V 6.3A 0 ~ 6.3A 76W DR-75-24 24V 3.2A 0 ~ 3.2A 76.8W 150mVp-p 24 ~ 28V DR-75-48 48V 1.6A 0 ~ 1.6A 76.8W 240mVp-p 48 ~ 53V 1.0% 0.5% 1.0% RIPPLE & NOISE (max.) Note.2 100mVp-p VOLTAGE ADJ. RANGE 12 ~ 14V VOLTAGE TOLERANCE Note.3 LINE REGULATION 2.0% 0.5% 1.0% 1000ms, 60ms, 50ms/230VAC 1.0% 0.5% 1.0% 1800ms, 60ms, 10ms/115VAC at full load LOAD REGULATION SETUP, RISE, HOLD TIME VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT (max.) LEAKAGE CURRENT OVER LOAD PROTECTION OVER VOLTAGE 85 ~ 264VAC 47 ~ 63Hz 76% 120 ~ 370VDC 80% 60A/230VAC 81% 2A/115V 1.2A/230V COLD START 30A/115VAC <1mA / 240VAC 105 ~ 150% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 15 ~ 16.5V 85 5 29 ~ 34V (TSW1) Detect on heat sink of power transistor (Refer to output load derating curve) 58 ~ 65V Protection type : Hiccup mode, recovers automatically after fault condition is removed Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -10 ~ +60 OVER TEMPERATURE WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0 ~ 50 VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS UL508, TUV EN60950 Approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMC EMI CONDUCTION & RADIATION Compliance to EN55011,EN55022 (CISPR22) Class B (Note 4) HARMONIC CURRENT EMS IMMUNITY MTBF OTHERS NOTE Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2 (EN50082-2) Heavy industry level, criteria A 123.1K hrs min. MIL-HDBK-217F (25 55.5*125.2*100mm (W*H*D) 0.6Kg; 20pcs/13Kg/1.1CUFT ) DIMENSION PACKING 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. TOTAL POWER INT'L 75W Single Output Industrial DIN Rail Power Supply Mechanical Specification DR-75 Case No. 923 series Unit:mm 100 125.2 TB1 1 2 3 LED TB2 1 2 3 4 +V ADJ. 55.5 ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15 Terminal Pin. No Assignment (TB1) Pin No. 1 2 3 Assignment FG AC/N AC/L 35 Terminal Pin. No Assignment (TB2) Pin No. 1,2 3,4 Assignment DC OUTPUT +V DC OUTPUT -V Output Derating Output Derating Vs Input Voltage 100 100 24V,48V 90 80 12V 80 70 60 LOAD (%) LOAD (%) 0 10 20 30 45 50 60 (VERTICAL) 40 60 50 40 20 -10 85 90 105 125 145 165 185 205 225 245 265 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz |
Price & Availability of DR-75-48
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |