![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
DPF600 SERIES Dual output * * * * * * * 600W front end EN61000-3-2 compliant Hot pluggable N+1 redundancy Full set of status signals EN55022, EN55011 conducted emissions level B UL, TUV, CSA and BABT approvals Patent No. 5446366 [ 2 YEAR WARRANTY ] The DPF600 is a 600W universal input AC/DC front end power supply in a fully enclosed hot pluggable case with built-in fan, front panel with handle, IEC input connector, on/off switch and DIN output signal connector. Providing dual 49V and 5V outputs with a full set of status signals, the DPF600 is designed as a slot-in front end for distributed power systems. The DPF600 provides 600W of output power and is fully compliant with EN61000-3-2. Standard features include current sharing and full protection against overvoltage, overload and short circuit. Remote or local system monitoring is possible via a full set of status signals that include fan fail, DC good, remote inhibit and current monitoring. The DPF600, with full international safety approval and the CE mark, meets conducted emissions EN55022 level B. The DPF600 is designed for use as a front end in medium power communication applications adopting distributed power architecture. The DPF600 can be used in conjunction with our complete range of 3 to 200W DC/DC converters to fully configure a distributed power system. SPECIFICATION OUTPUT SPECIFICATIONS Voltage set point Total regulation Rise time Transient response All specifications are typical at nominal input, full load at 25C unless otherwise stated EMC CHARACTERISTICS -49VDC 245mVDC with 2A load applied Radiated emissions Conducted emissions Harmonic current emm. Electrical fast transients/bursts Surge susceptibility EN55022/11, FCC part 15 EN55022/11, FCC part 15 EN61000-3-2 EN61000-4-4 EN61000-4-5 Level A Level B Compliant Level 3 Level 3 Main output Full load to no load At turn-on Main output 50% to 100% step at 1.0A/s Main output Auxiliary output Latching main output Latching 5.0% 0.5s, max. 5.0% max. dev., 1ms recovery to 1.0% 750mV pk-pk, 100mV pk-pk -55V to -60V 5.7V to 6.5V 750W GENERAL SPECIFICATIONS Hold-up time Efficiency Isolation voltage Switching frequency Approvals and standards Weight MTBF ENVIRONMENTAL SPECIFICATIONS Thermal performance Operating ambient 0C to +50C Non-operating -40C to +85C 50C to 70C ambient Derate to 50% Built-in fan Non-condensing Operating Non-operating 5Hz to 500Hz 5% to 85% RH 10,000 feet max. 40,000 feet max. 2.4G rms peak 120VAC, 60Hz FL 20ms @ 600W 82% min. 3000VAC 1500VAC 50kHz EN60950, UL1950, BABT CSA C22.2 No. 950 6.9kg (15Ibs) 500,000 hours demonstrated Ripple and noise (0Hz to 30MHz) Overvoltage protection Output power limit Short circuit protection Current sharing 100Vin, load >66% rated Input/output Input/chassis Non-latching Auto-recovery 10%, 3V droop from 15% to 100% INPUT SPECIFICATIONS Input voltage range Input frequency range Input surge current Input surge Safety ground leakage current Input current Input fuse Power factor 85 to 264VAC 47Hz to 63Hz 230VAC, cold start @ 25C 300VAC 120VAC, 60Hz 230VAC, 50Hz 90VAC, 600W 220VAC Non-replaceable 35A max. 20ms 0.2mA 0.4mA 7.35A rms max. 2.84A rms max. 15A Cooling Relative humidity Altitude Vibration International Safety Standard Approvals 0.99 120Vin, >66% load TUV VDE0805/EN60950/IEC950 UL1950 File No. E136005 CSA C22.2 No. 950 File No. LR41062C PAGE 1 Certificate No. 606090 DISTRIBUTED POWER FRONT END AC/DC POWER SUPPLIES | 600W AC/DC 600 Watt AC/DC PFC front-end for distributed power architectures OUTPUT VOLTAGE -49V (3) OUTPUT CURRENT RIPPLE MIN 0A (4) TOTAL REGULATION MODEL NUMBER MAX 12A 10A 750mV 50mV 5.0% DPF600-9617 5.0% (1,2) +5V Notes 1 2 3 4 0.2A Fan fail and power good are open collector signals. All signals are referenced to earth ground, as is the 5V output. The main output is floating. 49.5V at minimum current. STATUS AND CONTROL SIGNALS Fan fail H Power good L Inhibit L Current monitor Asserted in event of a failure Asserted when the output voltage is within specification Inhibits the main output when this pin is open or low Provides an analog voltage reflection of the main output current 1.25 (31.75) 11.94 (303.28) AIR FLOW 1.619 (REF.) (41.12) 6.73 (170.94) 2.18 (REF.) (55.37) 2.18 .02 (55.37 0.51) 1.47 .02 (37.34 0.51) 2.105 .015 (53.467 0.381) 1.47 (REF.) (37.34) .22 (2PL) (5.59) .806 .01 (20.47 0.25) 3.340 (84.84) 1.015 .01 (25.78 0.25) .985 REF (25.019) ALL DIMENSIONS IN INCHES (mm) PIN NUMBER Pin C6 Pin C8 Pin C4 Pin B6 Pins B1, C1 Pins A1-2 OUTPUT PIN CONNECTIONS FUNCTION PIN NUMBER Power Good H Pins A10-12 Inhibit L Pins B9-12 Current Monitor Pins C9-12 Fan Fail H Pins A-C, 13-16 -48V Fan Pin A9 -48V Fan Return Pin B8 Mating connectors FUNCTION 5V Output 5V Output 5V Output Ground +5V Sense Ground Sense Signal 48-pin female DIN connector Main output ICON connectors (ELCON P/N: 259-28-00100) Input IEC DS_DPF600_19980401.PDF Data Sheet (c) Artesyn Technologies(R) 2000 The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein. http://www.artesyn.com PAGE 2 |
Price & Availability of DPF600-9617
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |