If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
AXC-102 ACTIVE FILTER FOR RIPPLE ATTENUATION 20A PRELIMINARY Features : ? ? ? ? ? ? ? ? ? High Efficiency. Superior Performance at Low Frequencies. Output Impedance Less Than 5m. Retriggerable / Non-retriggerable Circuit Breaker. Shut Down. Sense Input Control. Status Output. Wide Operation Range 0-28V. Programmable Voltage Drop. ? Compact Size. Product Description The AXC-102 is a power filter which provide high attenuation starting at extremely low frequencies (30dB@20Hz). The device is designed for positive supply of 0 to 28 Volts and up to 20Amp load. The output voltage tracks the DC input voltage with 0.6V drop (adjustable). Full performance is kept for input ripple of up to 0.8 Volts p-p. Exceptional effort has been made to maintain low output impedance (less than 5m at audio frequencies). The AXC filters are designed to meet the most stringent noise requirements in electronic equipment, laboratory power supplies, audio equipment, etc. Sense input provides a constant DC voltage drop across the AXC102. A programmable current circuit breaker shuts down the device when the current trough the module exceeds the rated current (programmable). The circuit breaker has two modes of operation: Retriggerable and Non-retriggerable mode. A CBS (Circuit Breaker Status) indicates when the device is in disconnected mode. A low level voltage (less than 1V), at SD (Shut Down) input, shuts down the output voltage and the quiescent current drops below 2.5mA. This feature fits power management, as well as battery power saving applications. Applications ? ? ? ? ? Laboratory Power Supply. Mixed Signal Power Splitter. Automotive Power Filter. Professional Audio Systems. Power Management. Fig.1 - Typical Application +2.5V (OPTION) Bias Voltage NC 1 VD 7 PIN SD 8 NC NC NC 9 4 3 VEXT RTG CBS 10 6 C2 470uF Load Vo=0V - 28V +OUT +S C1 10uF AXC102 RET 5 POUT SNS CL 2 NC Lab. P.S. -S -OUT Ultra Low Noise, Lab. Power Supply September 98 Page 1 of 6 98002-05-003-02.doc IXYS Corporation 3540 Bassett Street, Santa Clara, CA 95054 TEL:408-982-0700 FAX:408-496-0670 IXYS Semiconductor, GmbH. Edisonstr. 15 D-68623 Lampertheim, Germany TEL:+49-6206-503-0 FAX:+49-6206-503-627 AXC-102 PRELIMINARY Absolute Maximum Ratings Parameter Supply Voltage Maximum Output Current SD Current SD Voltage CL Current CL Voltage VEXT Current VEXT Voltage CBS,RTG Current CBS,RTG Voltage VD Current VD Voltage SNS Current SNS Voltage Storage Temperature Operating Temperature Less than 100uSec Conditions Min 0 0 0 -2 -1 -10 -15 2.3 -10 PIN-1 POUT-1 -30 -30 Max 30 100 10 5 1 10 25 2.7 1 30 1 PIN+1 10 POUT+1 110 85 Units Vdc A mA V mA V mA V mA V mA V mA V C C DC Electrical Specification (-30C TA +85C) Parameter Operating Voltage Operation Current Quiescent Current VEXT Voltage VEXT Current Voltage Drop Conditions VEXT not connected VEXT connected to external 2.5V Normal Operation Shut Down Mode 2.50 4 0 0 Typ Max 28 28 20 26 2.25 2.6 26 0.62 0.68 0.62 1 2.5 100 2.5 1 20 20 22 5 Units V V A mA mA V mA V V V V mA mSec V V uA uA A A 22 2.5 10 0 0.2 0.60 0 2 50 1.5 0 SD OFF Position Voltage SD OFF Position Current Retriggerable Time CBS Output Voltage ON Position CBS Output Voltage Off Position CBS Output Current ON Position CBS Output Current Off Position Circuit Breaker Off Current RTG Not Connected R1* Not Connected R1*=0 20 4 * R1 See Fig.2 September 98 Page 2 of 6 98002-05-003-02.doc IXYS Corporation 3540 Bassett Street, Santa Clara, CA 95054 TEL:408-982-0700 FAX:408-496-0670 IXYS Semiconductor, GmbH. Edisonstr. 15 D-68623 Lampertheim, Germany TEL:+49-6206-503-0 FAX:+49-6206-503-627 AXC-102 PRELIMINARY AC Electrical Specification (-30C TA +85C) Operating Voltage 4-28V ; Output Current ILOAD=(0/ 20)A Parameter Insertion Loss Attenuation* Output Impedance Line Transient Attenuation Transient Output Impedance Conditions 20Hz / 10KHz @ 50 At 1Khz 10Hz-10Khz 10Hz / 10KHz Transient voltage less than 0.5V R2** does not exist Idc=2A; I=5A Min 40 55 27 26 Typ 50 61 30 4 30 Max 60 Units dB dB dB m dB m 6 6 *C1 = 10uF ,C2=470uF Electrolytic Capacitor ,R2 not exist; Maximum Input Noise Level = 0.8Vptp ** See Fig2. Fig.2 - Test Circuit Circuit Breaker Current Setting: I CIRCUIT [ A] = 720 + 240R * 1[ K ] 10% 150 + 11R * 1[ K ] VVROP External Bias I EXT VEXT A V SW 2 VCBS V R2 1 VD PIN SD 8 BREAKER V 10 6 C2 470uF VOUT I LOAD VCL 9 4 3 VEXT RTG CBS POUT 7 AXC102 SNS RET 5 CL 2 Vripple VIN C1 10uF Voltage Drop Setting: VDROP[V ] = 1.2R * 2[ K ] 5% 100 + 2 R * 2[ K ] + V - Vdc VSD I SD I CL V SW 1 A R1 A V V A *R1,R2 See Fig2. Fig.3 - Circuit Breaker Current Setting 25 20 0.6 0.5 Fig.4 - Voltage Drop Setting Icircuit breaker[A] 0.4 Vdrop[V] 15 10 5 0 0.3 0.2 0.1 0 1 10 100 1000 1 10 100 1000 R1[K ] R2[K ] September 98 Page 3 of 6 98002-05-003-02.doc IXYS Corporation 3540 Bassett Street, Santa Clara, CA 95054 TEL:408-982-0700 FAX:408-496-0670 IXYS Semiconductor, GmbH. Edisonstr. 15 D-68623 Lampertheim, Germany TEL:+49-6206-503-0 FAX:+49-6206-503-627 AXC-102 PRELIMINARY Load Transient Response Fig.5A Fig.5B Thermal Resistance Parameter Junction-to-Sink [ RJS ] Attenuation (Vout[ac]/Vripple) Typ 1.4 Max 1.6 Units C/W General Specifications Parameter Weight 342 Units gr. Fig.6 September 98 Page 4 of 6 98002-05-003-02.doc IXYS Corporation 3540 Bassett Street, Santa Clara, CA 95054 TEL:408-982-0700 FAX:408-496-0670 IXYS Semiconductor, GmbH. Edisonstr. 15 D-68623 Lampertheim, Germany TEL:+49-6206-503-0 FAX:+49-6206-503-627 AXC-102 PRELIMINARY Pin Description No Name Short Description No Name Short Description Fig.8 - Mechanical Drawing 28 2 1 2 3 4 5 VD CL CBS RTG RET Voltage Drop Current Limit Circuit Breaker Status Retriggerable Mode Ground 7 89 6 7 8 9 10 SNS PIN SD VEXT POUT 10 Sense Input Positive Input Shut Down External Bias Positive Output 13.5 11.8 1 35 (35x26 DCB Ceramic) 48 6.9 2 11 31.6 10.13 65 43 21 16.8 10.87 10.87 2.54 2.54 63 2.54 16.8 Fig.7 Typical Applications Optional NC NC 1 9 4 3 VD VEXT RTG CBS 7 PIN SD 8 Car Battery C1 100uF L1 100uHy AXC102 RET 5 POUT SNS CL 2 NC 10 6 Optional Shut Down C2 500uF Load Fig.9A - Input Power Filter For Sensitive Vehicle Electronic Equipment September 98 Page 5 of 6 98002-05-003-02.doc IXYS Corporation 3540 Bassett Street, Santa Clara, CA 95054 TEL:408-982-0700 FAX:408-496-0670 IXYS Semiconductor, GmbH. Edisonstr. 15 D-68623 Lampertheim, Germany TEL:+49-6206-503-0 FAX:+49-6206-503-627 4 5.3 10.06 0.5 45 44 AXC-102 PRELIMINARY Typical Applications +2.5V (OPTION) Bias Voltage NC NC NC 1 9 4 3 VD VEXT RTG CBS 7 PIN SD 8 NC +OUT +S C1 10uF Lab. P.S. AXC102 RET 5 POUT SNS CL 2 NC 10 6 Vo=0V - 28V C2 470uF Load -S -OUT Fig.9B - Ultra Low Noise, High Efficiency Laboratory Switch-Mode Power Supply Digital Load Optional NC NC 1 9 4 3 VD VEXT RTG CBS +OUT +S C1 10uF 7 PIN SD 8 POUT 10 6 AXC102 SNS RET 5 CL 2 NC S.M.P.S -S -OUT Optional Shut Down C2 500uF Analog Load Fig.9C - Analog Digital Power Supply Decoupler (Sensitive Analog Load). September 98 Page 6 of 6 98002-05-003-02.doc IXYS Corporation 3540 Bassett Street, Santa Clara, CA 95054 TEL:408-982-0700 FAX:408-496-0670 IXYS Semiconductor, GmbH. Edisonstr. 15 D-68623 Lampertheim, Germany TEL:+49-6206-503-0 FAX:+49-6206-503-627 |
Price & Availability of AXC-102
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |