 02/29/00
Errata: CS43L43 Data Sheet Correction
(Reference CS43L43 Data Sheet revision DS479PP1 dated Feb `00)
The following is a correction to the CS43L43 Data Sheet revision DS479PP1, FEB'00. The changes in this errata will be corrected in the next revision of the data sheet. The Control Port Enable bit, CP_EN, was inadvertently omitted from the register description section in the data sheet. Register 01h should include the CP_EN in bit location 0 as follows: POWER AND MUTING CONTROL (ADDRESS 01H)
7 AMUTE 1 6 SCZ1 1 5 SCZ0 0 4 POR 1 3 Reserved 0 2 Reserved 0 1 PDN 1 0 CP_EN 0
CONTROL PORT ENABLE (CP_EN) Default - 0 0 - Disabled 1 - Enabled Function: The Control Port will become active and reset to the default settings when this function is enabled.
If there are any questions concerning this information, Please contact Applications Engineering: (512) 445-7222
Cirrus Logic P.O. Box 17847, Austin, Texas 78760 (512) 445 7222 FAX: (512) 445 7581 http://www.cirrus.com ER479A1 FEB `00 1