Part Number Hot Search : 
W45NM60 SWB804 SPB18P 00X197 LM239P KSD08 MP93P E2505H46
Product Description
Full Text Search
 

To Download A5800184 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Liquid crystal displays
16 16 dots transmissive large-sized liquid crystal display unit
RCM1277U
Thanks to the high contrast and wide viewing angle of the RCM1277U, which is provided by its unique design technology, this module brings forth new applications in brand new LCD fields. ROHM large-sized LCD units are perfect displays for information or sign boards. As a media for informational display, large-sized LCD units must possess high visibility, wide viewing angles, and other such superior qualities. ROHM large-sized LCDs boast an excellent track record and possess guaranteed functionality for assured satisfaction in a variety of situations.
FApplications Public displays such as airport displays, train station displays, information boards, and billboards.
FExternal dimensions (Units: mm)
FFeatures 1) Wide viewing angle, high contrast, and fast response. 2) Compact and light weight for easy assembly. 3) Supports negative or positive display. 4) Low power consumption.
126
Liquid crystal displays
FBlock diagram
RCM1277U
FPin functions (1) Input (CN1)
(2)
Output (CN2)
127
Liquid crystal displays
FAbsolute maximum ratings (Ta = 25_C)
RCM1277U
FElectrical characteristics (VDD = 5.0 V 0.25 V, Ta = 25_C)
FAC characteristics (VDD = 5.0 V, GND = 0 V, Ta = 25_C)
FTiming characteristics
128
Liquid crystal displays
FOptical characteristics (Ta = 25_C)
RCM1277U
(Note 1) Drive waveform Static drive
(3)
Maximum viewing angle: The direction with highest contrast expressed at the time axis (refer to above table). (Note 4) Definition of contrast ratio Definition Luminance during application of non-selective waveform Contrast ratio= Luminance during application of selective waveform Except, n = 1 with positive display and n = *1 with negative display. Measurement conditions Drive conditions: As per specifications Viewing angle: = 180_ , = 10_ (Note 5) Principles of optical measuring equipment n
(Note 2) Definition of response speed
Tr : Time for segment to darken 90% after selective waveform switches to non-selective waveform. = 180_ , = 10_ Td : Time for segment to darken 90% after selective waveform switches to non-selective waveform. = 180_ , = 10_ (Note 3) Definition of viewing angle (, )
(1) (2)
: Angle subtended by the Y-Y'-axis and the observer's position projected onto the XY-plane. : Angle subtended by observer and the normal Z-Z'-axis (X-axis and Y-axis are positive)
129
Liquid crystal displays
FData format (data and display mapping)
RCM1277U
130
Liquid crystal displays
FTiming chart
RCM1277U
131
Liquid crystal displays
FOperation notes (1) Attention points in handling S Protect the module from strong shocks as they can cause damage or defective operation. S The polarizing plate on the surface of the module is soft and can easily be scratched. Wipe away dirt and dust using an alcohol-based cleanser. S If the liquid crystal panel is damaged and liquid crystal contacts your clothing or body, wash immediately with soap and water. S Do not touch the IC lead electrodes or the electrode terminal components. S If the module is to be used for long periods subjected to direct sunlight, employ a filter to block the ultraviolet rays. S Do not store the module in areas of high temperature or high humidity. Do not store the module in locations exposed to direct sunlight or fluorescent light. S During handling of the module, in order to prevent damage to the tab, do not bend it more than two times. (2) Precautions during operation S Do not connect or disconnect the module while the power supply is turned on. S Input the input signal after the module power supply is turned on. When turning it off, turn off the input signal first. Otherwise the IC may be damaged by the latchup phenomenon. (3) Precautions during installation S Be careful to avoid damage from static electricity. A CMOS-IC is used in the modules circuitry that can be easily damaged by static electricity. S A protective film is pasted over the front and back of the module to protect the panel surfaces. When peeling this film off, be sure to peel as slow as possible in order to minimize the generation of static electricity. Use of a ion blower or other deionizing device is recommended.
RCM1277U
132


▲Up To Search▲   

 
Price & Availability of A5800184

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X