 05072
CPE 80
&
Only One Name Means ProT ek'TionTM
MB 80
MOTHERBOARD & ENCLOSURE
APPLICA TIONS
CPE 80 ENCLOSURE
Multiple Data Line Panel Protection Emergency Shutdown Systems Process Control Panels FEA TURES MB 80: Glass Filled Laminate Circuit Board with Stand-Offs CPE 80: Rugged Cast Aluminum Two-Tone Baked Enamel Base & Removable Cover Wiring Interface Accepts a Maximum of Eight(8) Circuit Boards Two 10-32 Brass Ground Studs for Low Impedance Motherboard is Clearly Marked for Easy Installation MECHANICAL CHARACTERISTICS Screw Type Stripline Connectors for AWG 20-24 Wire Four (4) Mounting Holes for #8 Screws Approximate Weight of the MB 80: 340 grams Approximate Weight of the CPE 80: 1.6 kilograms Dimensions of the MB 80: 9"H (22.9 cm) x 5.5"W (14 cm), with 3" (7.6 cm) Minimum Interface Depth if Mounting in an Enclosure Dimensions of the CPE 80: 9.5"H (24.1 cm) x 6.25"W (15.8 cm), with 3.5" (8.9 cm) Minimum Interface Depth if Mounting in an Enclosure DESCRIPTION The CPE 80 and MB 80 provides protection of 32 data lines using up to eight (8) SPDs (surge protection device). These products accomodate a variety of SPDs such as 232B, 422B and 420LB; which are not included with the motherboard or enclosure. Available from ProTek Devices, each data line SPD has four, two stage protection circuits. The SPDs provide primary and secondary protection against lightning, inductive switching and ESD transient threats. The first stage diverts the transient current through the ground terminal return part and the second stage clamps the voltage to a safe level without interruption of service. These interface board assemblies are located between the unprotected transient threat environment (incoming data lines) and the protected sensitive electronic equipment or system. The motherboard is marked identifying the protected side. The unprotected side should be located away from the protected data line cables. The MB 80 is a motherboard containing eight (8) edge card connectors and two (2) strip terminal blocks. The edge card connectors are soldered onto the motherboard, which is connected to the terminal blocks by copper traces. The terminal blocks have screw type connections for easy installation between the unprotected and the protected equipment. Data line surge protection devices are inserted into the edge card connectors for protection of sensitive equipment and/or systems. The CPE 80 includes a motherboard (MB 80) inside a rugged, cast aluminum housing with a removable cover. The housing contains two (2) holes on either side of the case for data line cables. Mounting hardware is provided for the data line cables.
MB 80 MOTHERBOARD
05072.R2 1/03
1
www.protekdevices.com
CPE 80
&
MB 80
INST ALLA TION INSTRUCTIONS
Maximum transient protection requires a good ground system. This consists of a common bonded or ground system, which interconnects AC power and data line grounds. A single ground connection is sufficient. However, it is more important that the ground be a low impedance path to the earth. A good earth connection is necessary for lightning transient threat conditions. Connections are usually best using a ground strap where the cross-sectional area of the ground connection is maximized. The ground connection is made through the green AC power ground wire or to a known earth ground system. If a ground wire is used, it is recommended that it is a #14 stranded wire. A low impedence ground is important to minimize a ground voltage potential rise that may cause ground bounce within the system or equipment.
TYPICAL WIRING FORMAT FOR ONE 4 WIRE RS EIA STANDARD DATA LINE PRODUCTS
Figure 1 Example of ProTek 15 pin protection board, such as 232B, 485B and TEL185B
To Common Equipment-Ground Point AWG 6-10 Wire
PROTECTED SIDE
Connect to CPU or Peripheral Equipment
UNPROTECTED SIDE GROUND LUG
Connect to External Data Lines
1AP 2AP 3AP 4AP 1BP
1AU 2AU 3AU 4AU 1BU
Orient Board as Shown
CPE & MB 80 WIRING CONFIGURATION
Figure 2
MB 80 INSTALLATION INSTRUCTIONS
1. Select a suitable mounting location within 10 meters of the protected equipment. An enclosure is recommended to protect against dust and moisture. 2. Mount the board using the stand-offs and #8 screws provided. 3. Connect wires to appropriate terminals as show in Figures 1 and 2. The ground wire MUST be kept on the unprotected side of the board. 4. Insert protected boards. Be certain to insert boards in the correct position as shown on the MB 80. Cover Bolt
PROTECTED SIDE
Connect to CPU or Peripheral Equipment
UNPROTECTED SIDE GROUND LUG
Connect to External Data Lines
4 Wires per Data Line
1AP
R
1AU 2AU 3AU 4AU 1BU 2BU
Orient Board as Shown
2AP 3AP 4AP 1BP 2BP 3BP 4BP 1CP 2CP
Mounting Screws 4 Wires per Data Line Inside Mouting Nut To Outside World
3BU 4BU 1CU 2CU
To Protected Equipment
PART NUMBER 31340-00001 - For use with Computer Data Line Protector Boards
3CP 4CP 1DP 2DP 3DP 4DP 1EP 2EP 3EP 4EP 1FP 2FP 3FP 4FP 1GP 2GP 3GP 4GP 1HP 2HP 3HP 4HP
Orient Board as Shown
3CU 4CU 1DU 2DU
CPE 80 INSTALLATION INSTRUCTIONS
1. Select a suitable mounting location within 10 meters of the protected equipment. 2. Remove the cover and install retainer assembly in holes. Do not tighten gland nut bushing. See cable retainer assembly detail in Figure 1. 3. Install base on a flat surface using #8 screws provided. 4. Insert wires through cable retainer assemblies and connect to appropriate terminals as shown in Figures 1 and 2. The ground wire MUST enter the enclosure ONLY through the unprotected side. 5. After completion of wiring, hand tighten gland nut bushing. 6. Insert protector boards. Be certain to insert boards in the correct position as shown on the printed circuit board. 7. Replace cover and tighten cover mounting screws.
Orient Board as Shown
3DU 4DU 1EU 2EU
Data Line Cable
Orient Board as Shown
3EU 4EU 1FU 2FU
Orient Board as Shown
3FU 4FU 1GU 2GU
Orient Board as Shown
3GU 4GU 1HU 2HU
Gland Nut Retaining Nut Nylon Washer
Orient Board as Shown
3HU 4HU
Orient Board as Shown
GROUND LUG
To Common Equipment-Ground Point AWG 6-10 Wire
COPYRIGHT (c) ProTek Devices 2005 SPECIFICATIONS: ProTek reserves the right to change the electrical and or mechanical characteristics described herein without notice (except JEDEC). DESIGN CHANGES: ProTek reserves the right to discontinue product lines without notice, and that the final judgement concerning selection and specifications is the buyer's and that in furnishing engineering and technical assistance, ProTek assumes no responsibility with respect to the selection or specifications of such products.
ProTek Devices 2929 South Fair Lane, Tempe, AZ 85282 Tel: 602-431-8101 Fax: 602-431-2288 E-Mail: sales@protekdevices.com Web Site: www.protekdevices.com
05072.R2 1/03
2
www.protekdevices.com


▲Up To Search▲   

 
Price & Availability of MB80

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X