If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
APTM120DA15 Boost chopper MOSFET Power Module VBUS CR1 VDSS = 1200V RDSon = 150m max @ Tj = 25C ID = 60A @ Tc = 25C Application * * * AC and DC motor control Switched Mode Power Supplies Power Factor Correction OUT Features Q2 * G2 S2 0/VBUS * * * VBUS 0/VBUS OUT Power MOS 7(R) MOSFETs - Low RDSon - Low input and Miller capacitance - Low gate charge - Avalanche energy rated - Very rugged Kelvin source for easy drive Very low stray inductance - Symmetrical design - M5 power connectors High level of integration Benefits * * * * Outstanding performance at high frequency operation Direct mounting to heatsink (isolated package) Low junction to case thermal resistance Low profile S2 G2 Absolute maximum ratings Symbol VDSS ID IDM VGS RDSon PD IAR EAR EAS Parameter Drain - Source Breakdown Voltage Continuous Drain Current Pulsed Drain current Gate - Source Voltage Drain - Source ON Resistance Maximum Power Dissipation Avalanche current (repetitive and non repetitive) Repetitive Avalanche Energy Single Pulse Avalanche Energy Tc = 25C Tc = 80C Tc = 25C mJ These Devices are sensitive to Electrostatic Discharge. Proper Handing Procedures Should Be Followed. APT website - http://www.advancedpower.com 1-6 APTM120DA15- Rev 0 July, 2004 Max ratings 1200 60 45 240 30 150 1250 22 50 3000 Unit V A V m W A APTM120DA15 All ratings @ Tj = 25C unless otherwise specified Electrical Characteristics Symbol BVDSS IDSS RDS(on) VGS(th) IGSS Characteristic Drain - Source Breakdown Voltage Zero Gate Voltage Drain Current Drain - Source on Resistance Gate Threshold Voltage Gate - Source Leakage Current Test Conditions VGS = 0V, ID = 1mA Min 1200 VGS = 0V,VDS = 1200V VGS = 0V,VDS = 1000V T j = 25C T j = 125C Typ Max 400 2000 150 5 250 Unit V A m V nA VGS = 10V, ID = 30A VGS = VDS, ID = 10mA VGS = 30 V, VDS = 0V 3 Dynamic Characteristics Symbol Ciss Coss Crss Qg Qgs Qgd Td(on) Tr Td(off) Tf Eon Eoff Eon Eoff Characteristic Input Capacitance Output Capacitance Reverse Transfer Capacitance Total gate Charge Gate - Source Charge Gate - Drain Charge Turn-on Delay Time Rise Time Turn-off Delay Time Fall Time Turn-on Switching Energy Turn-off Switching Energy Turn-on Switching Energy Turn-off Switching Energy Test Conditions VGS = 0V VDS = 25V f = 1MHz VGS = 10V VBus = 600V ID = 60A Inductive switching @ 125C VGS = 15V VBus = 800V ID = 60A R G = 1.2 Inductive switching @ 25C VGS = 15V, VBus = 800V ID = 60A, R G = 1.2 Inductive switching @ 125C VGS = 15V, VBus = 800V ID = 60A, R G = 1.2 Min Typ 20.6 3.08 0.52 748 96 480 20 15 160 45 3.96 2.74 6.26 3.43 Max Unit nF nC ns mJ mJ Diode ratings and characteristics Symbol Characteristic IF(A V) Maximum Average Forward Current VF Diode Forward Voltage trr Qrr Reverse Recovery Time Reverse Recovery Charge Tj = 125C 4000 APT website - http://www.advancedpower.com 2-6 APTM120DA15- Rev 0 Eon includes diode reverse recovery. In accordance with JEDEC standard JESD24-1. July, 2004 Test Conditions 50% duty cycle IF = 60A IF = 120A IF = 60A IF = 60A VR = 800V di/dt = 200A/s IF = 60A VR = 800V di/dt = 200A/s Min Tc = 70C Tj = 125C Tj = 25C Tj = 125C Tj = 25C Typ 60 2 2.3 1.8 400 470 1200 Max 2.5 Unit A V ns nC APTM120DA15 Thermal and package characteristics Symbol Characteristic RthJC VISOL TJ TSTG TC Torque Wt Junction to Case Operating junction temperature range Storage Temperature Range Operating Case Temperature Mounting torque Package Weight To heatsink For terminals M6 M5 Transistor Diode 2500 -40 -40 -40 3 2 Min Typ Max 0.1 0.9 150 125 100 5 3.5 280 Unit C/W V C N.m g RMS Isolation Voltage, any terminal to case t =1 min, I isol<1mA, 50/60Hz Package outline APT website - http://www.advancedpower.com 3-6 APTM120DA15- Rev 0 July, 2004 APTM120DA15 Typical Performance Curve Maximum Effective Transient Thermal Impedance, Junction to Case vs Pulse Duration 0.12 Thermal Impedance (C/W) 0.1 0.08 0.06 0.04 0.02 0.9 0.7 0.5 0.3 0.1 0.05 0.0001 0.001 Single Pulse 0.01 0.1 1 10 0 0.00001 rectangular Pulse Duration (Seconds) Low Voltage Output Characteristics 200 VGS =15, 10 & 8V Transfert Characteristics 320 280 ID, Drain Current (A) VDS > I D(on)xRDS(on)MAX 250s pulse test @ < 0.5 duty cycle I D, Drain Current (A) 160 120 80 40 0 0 5 10 15 20 7V 6.5V 240 200 160 120 80 40 0 TJ=25C TJ=125C 0 1 2 3 4 5 6 TJ=-55C 7 8 9 6V 5.5V 5V 25 30 VDS, Drain to Source Voltage (V) RDS(on) vs Drain Current ID, DC Drain Current (A) Normalized to VGS =10V @ 30A VGS, Gate to Source Voltage (V) DC Drain Current vs Case Temperature 70 60 50 40 30 20 10 0 25 50 75 100 125 150 RDS(on) Drain to Source ON Resistance 1.4 1.3 1.2 1.1 1 0.9 0.8 0 VGS=10V VGS=20V 40 80 120 160 ID, Drain Current (A) TC, Case Temperature (C) July, 2004 APT website - http://www.advancedpower.com 4-6 APTM120DA15- Rev 0 APTM120DA15 RDS(on), Drain to Source ON resistance (Normalized) Breakdown Voltage vs Temperature BVDSS, Drain to Source Breakdown Voltage (Normalized) 1.15 1.10 1.05 1.00 0.95 0.90 0.85 -50 -25 0 25 50 75 100 125 150 TJ, Junction Temperature (C) Threshold Voltage vs Temperature 1.2 VGS(TH), Threshold Voltage (Normalized) I D, Drain Current (A) 1.1 1.0 0.9 0.8 0.7 0.6 -50 -25 0 25 50 75 100 125 150 TC, Case Temperature (C) Capacitance vs Drain to Source Voltage VGS, Gate to Source Voltage (V) 100000 Ciss C, Capacitance (pF) 10000 Coss 14 12 10 8 6 4 2 0 0 160 320 480 640 800 960 Gate Charge (nC) I D=60A TJ=25C V DS=240V VDS=600V V DS =960V ON resistance vs Temperature 2.5 2.0 1.5 1.0 0.5 0.0 -50 -25 0 25 50 75 100 125 150 TJ, Junction Temperature (C) Maximum Safe Operating Area VGS =10V ID=30A 1000 100s 100 limited by RDS on 1ms 10 Single pulse TJ =150C 1 1 10ms 1200 10 100 1000 VDS, Drain to Source Voltage (V) Gate Charge vs Gate to Source Voltage 1000 Crss 100 0 10 20 30 40 50 VDS, Drain to Source Voltage (V) APT website - http://www.advancedpower.com 5-6 APTM120DA15- Rev 0 July, 2004 APTM120DA15 Delay Times vs Current 180 td(on) and td(off) (ns) 150 60 V DS=800V RG=1.2 T J=125C L=100H Rise and Fall times vs Current 80 VDS=800V RG=1.2 T J=125C L=100H t d(off) tf 90 60 30 0 20 tr and tf (ns) 120 40 tr 20 t d(on) 0 40 60 80 100 120 140 20 40 I D, Drain Current (A) Switching Energy vs Current 60 80 100 120 I D, Drain Current (A) 140 Switching Energy vs Gate Resistance 12 Switching Energy (mJ) 10 8 6 4 2 0 20 40 60 80 100 120 140 ID, Drain Current (A) Operating Frequency vs Drain Current 14 Switching Energy (mJ) VDS=800V RG=1.2 TJ=125C L=100H Eon 12 10 8 6 4 V DS=800V ID=60A T J=125C L=100H Eoff Eoff Eon 2 0.00 1.25 2.50 3.75 5.00 6.25 7.50 8.75 Gate Resistance (Ohms) Source to Drain Diode Forward Voltage 200 Frequency (kHz) 150 100 50 0 5 15 25 35 45 ID, Drain Current (A) 55 V DS=800V D=50% R G=1.2 T J=125C T C=75C ZCS ZVS IDR, Reverse Drain Current (A) 250 1000 100 TJ=150C TJ=25C 10 Hard switching 1 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 VSD, Source to Drain Voltage (V) APT's products are covered by one or more of U.S patents 4,895,810 5,045,903 5,089,434 5,182,234 5,019,522 5,262,336 6,503,786 5,256,583 4,748,103 5,283,202 5,231,474 5,434,095 5,528,058 and foreign patents. U.S and Foreign patents pending. All Rights Reserved. APT website - http://www.advancedpower.com 6-6 APTM120DA15- Rev 0 APT reserves the right to change, without notice, the specifications and information contained herein July, 2004 |
Price & Availability of APTM120DA15
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |