FUJITSU SEMICONDUCTOR DATA SHEET
DS05-20860-3E
FLASH MEMORY
CMOS
8M (1M x 8/512K x 16) BIT
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
s FEATURES
* Single 3.0 V read, program, and erase Minimizes system level power requirements * Simultaneous operations Read-while-Erase or Read-while-Program * Compatible with JEDEC-standard commands Uses same software commands as E2PROMs * Compatible with JEDEC-standard world-wide pinouts (Pin compatible with MBM29LV800TA/BA) 48-pin TSOP(I) (Package suffix: PFTN - Normal Bend Type, PFTR - Reversed Bend Type) 48-ball FBGA (Package suffix: PBT) * Minimum 100,000 program/erase cycles * High performance 70 ns maximum access time * Sector erase architecture Two 16K byte, four 8K bytes, two 32K byte, and fourteen 64K bytes. Any combination of sectors can be concurrently erased. Also supports full chip erase. * Boot Code Sector Architecture T = Top sector B = Bottom sector * Embedded EraseTM Algorithms Automatically pre-programs and erases the chip or any sector * Embedded ProgramTM Algorithms Automatically writes and verifies data at specified address * Data Polling and Toggle Bit feature for detection of program or erase cycle completion * Ready/Busy output (RY/BY) Hardware method for detection of program or erase cycle completion * Automatic sleep mode When addresses remain stable, automatically switch themselves to low power mode. * Low VCC write inhibit 2.5 V * Erase Suspend/Resume Suspends the erase operation to allow a read in another sector within the same device
(Continued)
Embedded EraseTM and Embedded ProgramTM are trademarks of Advanced Micro Devices, Inc.
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
(Continued) * Sector protection Hardware method disables any combination of sectors from program or erase operations * Sector Protection Set function by Extended sector protection command * Fast Programming Function by Extended Command * Temporary sector unprotection Temporary sector unprotection via the RESET pin.
s PACKAGE
48-pin plastic TSOP (I)
Marking Side
48-pin plastic TSOP (I)
Marking Side
(FPT-48P-M19)
(FPT-48P-M20)
48-pin plastic FBGA
(BGA-48P-M02) (BGA-48P-M12)
2
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
s GENERAL DESCRIPTION
The MBM29DL800TA/BA are a 8M-bit, 3.0 V-only Flash memory organized as 1M bytes of 8 bits each or 512K words of 16 bits each. The MBM29DL800TA/BA are offered in a 48-pin TSOP(I) and 48-ball FBGA packages. These devices are designed to be programmed in-system with the standard system 3.0 V VCC supply. 12.0 V VPP and 5.0 V VCC are not required for write or erase operations. The devices can also be reprogrammed in standard EPROM programmers. MBM29DL800TA/BA provides simultaneous operation which can read a data while program/erase. The simultaneous operation architecture provides simultaneous operation by dividing the memory space into two banks. The device can allow a host system to program or erase in one bank, then immediately and simultaneously read from the other bank. The standard MBM29DL800TA/BA offer access times 70 ns and 120 ns, allowing operation of high-speed microprocessors without wait states. To eliminate bus contention the devices have separate chip enable (CE), write enable (WE), and output enable (OE) controls. The MBM29DL800TA/BA are pin and command set compatible with JEDEC standard E2PROMs. Commands are written to the command register using standard microprocessor write timings. Register contents serve as input to an internal state-machine which controls the erase and programming circuitry. Write cycles also internally latch addresses and data needed for the programming and erase operations. Reading data out of the devices is similar to reading from 5.0 V and 12.0 V Flash or EPROM devices. The MBM29DL800TA/BA are programmed by executing the program command sequence. This will invoke the Embedded Program Algorithm which is an internal algorithm that automatically times the program pulse widths and verifies proper cell margin. Typically, each sector can be programmed and verified in about 0.5 seconds. Erase is accomplished by executing the erase command sequence. This will invoke the Embedded Erase Algorithm which is an internal algorithm that automatically preprograms the array if it is not already programmed before executing the erase operation. During erase, the devices automatically time the erase pulse widths and verify proper cell margin. A sector is typically erased and verified in 1.0 second. (If already completely preprogrammed.) The devices also feature a sector erase architecture. The sector mode allows each sector to be erased and reprogrammed without affecting other sectors. The MBM29DL800TA/BA are erased when shipped from the factory. The devices feature single 3.0 V power supply operation for both read and write functions. Internally generated and regulated voltages are provided for the program and erase operations. A low VCC detector automatically inhibits write operations on the loss of power. The end of program or erase is detected by Data Polling of DQ7, by the Toggle Bit feature on DQ6, or the RY/BY output pin. Once the end of a program or erase cycle has been completed, the devices internally reset to the read mode. Fujitsu's Flash technology combines years of EPROM and E2PROM experience to produce the highest levels of quality, reliability, and cost effectiveness. The MBM29DL800TA/BA memories electrically erase the entire chip or all bits within a sector simultaneously via Fowler-Nordhiem tunneling. The bytes/words are programmed one byte/word at a time using the EPROM programming mechanism of hot electron injection.
3
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
s FLEXIBLE SECTOR-ERASE ARCHITECTURE
* Two 16K bytes, four 8K bytes, two 32K bytes, and fourteen 64K bytes * Individual-sector, multiple-sector, or bulk-erase capability * Individual or multiple-sector protection is user definable.
(x8) 16K byte
(x16) 64K byte
(x8)
(x16)
FFFFFH 7FFFFH FBFFFH 7DFFFH 8K byte F9FFFH 7CFFFH 8K byte F7FFFH 7BFFFH 32K byte EFFFFH 77FFFH 64K byte DFFFFH 6FFFFH 64K byte CFFFFH 67FFFH 64K byte BFFFFH 5FFFFH 64K byte AFFFFH 57FFFH 64K byte 9FFFFH 4FFFFH 64K byte 8FFFFH 47FFFH 64K byte 7FFFFH 3FFFFH 64K byte 6FFFFH 37FFFH 64K byte 5FFFFH 2FFFFH 64K byte 4FFFFH 27FFFH 64K byte 3FFFFH 1FFFFH 64K byte 2FFFFH 17FFFH 64K byte 1FFFFH 0FFFFH 64K byte 0FFFFH 07FFFH 64K byte 00000H 00000H MBM29LV800TA Sector Architecture 16K byte 8K byte 8K byte 32K byte 64K byte 64K byte 64K byte 64K byte 64K byte 64K byte 64K byte 64K byte 64K byte 64K byte 64K byte 64K byte 64K byte 64K byte
FFFFFH 7FFFFH EFFFFH 77FFFH DFFFFH 6FFFFH CFFFFH 67FFFH BFFFFH 5FFFFH AFFFFH 57FFFH 9FFFFH 4FFFFH 8FFFFH 47FFFH 7FFFFH 3FFFFH 6FFFFH 37FFFH 5FFFFH 2FFFFH 4FFFFH 27FFFH 3FFFFH 1FFFFH 2FFFFH 17FFFH 1FFFFH 0FFFFH 0FFFFH 07FFFH 07FFFH 03FFFH 05FFFH 02FFFH 03FFFH 01FFFH 00000H 00000H MBM29LV800BA Sector Architecture
4
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
s PRODUCT LINE UP
Part No. VCC = 3.3 V Ordering Part No. VCC = 3.0 V Max. Address Access Time (ns) Max. CE Access Time (ns) Max. OE Access Time (ns)
+0.3 V -0.3 V +0.6 V -0.3 V
MBM29DL800TA/MBM29DL800BA -70 -- 70 70 30 -- -90 90 90 35 -- -12 120 120 50
s BLOCK DIAGRAM
RY/BY Buffer V CC V SS Erase Voltage Generator Input/Output Buffers DQ 0 to DQ 15 RY/BY
WE BYTE RESET State Control Command Register Program Voltage Generator CE OE Chip Enable Output Enable Logic STB Data Latch
STB
Y-Decoder
Y-Gating
Low V CC Detector
Timer for Program/Erase
Address Latch
X-Decoder
Cell Matrix
A0 to A18 A-1
5
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
s CONNECTION DIAGRAMS
TSOP(I) A15 A14 A13 A12 A11 A10 A9 A8 N.C. N.C. WE RESET N.C. N.C. RY/BY A18 A17 A7 A6 A5 A4 A3 A2 A1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 (Marking Side) 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 A16 BYTE VSS DQ 15/A-1 DQ7 DQ14 DQ6 DQ13 DQ5 DQ12 DQ4 VCC DQ11 DQ3 DQ10 DQ2 DQ9 DQ1 DQ8 DQ0 OE VSS CE A0 RY/BY A18 A17 A7 A6 A5 A4 A3 A2 A1 A0 CE VSS OE 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 A0 CE VSS OE DQ0 DQ8 DQ1 DQ9 DQ2 DQ10 DQ3 DQ11 VCC DQ4 DQ12 DQ5 DQ13 DQ6 DQ14 DQ7 DQ15/A-1 VSS BYTE A16 DQ0 DQ8 DQ1 DQ9 DQ2 DQ10 DQ3 DQ11 1 2 3 4 5 6 7 8 9
SOP (Top View) 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 RESET WE A8 A9 A10 A11 A12 A13 A14 A15 A16 BYTE V SS DQ 15/A-1 DQ 7 DQ 14 DQ 6 DQ 13 DQ5 DQ 12 DQ4 VCC
MBM29LV800TA/MBM29LV800BA Standard Pinout
10 11 12 13 14 15 16 17 18 19 20 21 22
FPT-48P-M19 A1 A2 A3 A4 A5 A6 A7 A17 A18 RY/BY N.C. N.C. RESET WE N.C. N.C. A8 A9 A10 A11 A12 A13 A14 A15 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 (Marking Side)
MBM29LV800TA/MBM29LV800BA Reverse Pinout
FPT-44P-M16
FPT-48P-M20
6
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
(Continued)
FBGA
(Top View)
Marking side
A1 B1 C1 D1 E1 F1 G1 H1 A2 B2 C2 D2 E2 F2 G2 H2 A3 B3 C3 D3 E3 F3 G3 H3 A4 B4 C4 D4 E4 F4 G4 H4 A5 B5 C5 D5 E5 F5 G5 H5 A6 B6 C6 D6 E6 F6 G6 H6
BGA-48P-M02 BGA-48P-M12
A1 B1 C1 D1 E1 F1 G1 H1
A3 A4 A2 A1 A0 CE OE VSS
A2 B2 C2 D2 E2 F2 G2 H2
A7 A17 A6 A5 DQ0 DQ8 DQ9 DQ1
A3 B3 C3 D3 E3 F3 G3 H3
RY/BY N.C. A18 N.C. DQ2 DQ10 DQ11 DQ3
A4 B4 C4 D4 E4 F4 G4 H4
WE RESET N.C. N.C. DQ5 DQ12 VCC DQ4
A5 B5 C5 D5 E5 F5 G5 H5
A9 A8 A10 A11 DQ7 DQ14 DQ13 DQ6
A6 B6 C6 D6 E6 F6 G6 H6
A13 A12 A14 A15 A16 BYTE DQ15/A-1 VSS
7
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
s LOGIC SYMBOL
Table 1 Pin
A-1 19 A0 to A18 DQ 0 to DQ 15 16 or 8
MBM29DL800TA/BA Pin Configuration Function Address Inputs Data Inputs/Outputs Chip Enable Output Enable Write Enable Ready/Busy Output Hardware Reset Pin/Temporary Sector Unprotection Selects 8-bit or 16-bit mode No Internal Connection Device Ground Device Power Supply
A-1, A0 to A18 DQ0 to DQ15 CE OE
CE OE WE RESET BYTE RY/BY
WE RY/BY RESET BYTE N.C. VSS VCC
8
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
Table 2 Operation Auto-Select Manufacturer Code (1) Auto-Select Device Code (1) Read (3) Standby Output Disable Write (Program/Erase) Enable Sector Protection (2), (4) Verify Sector Protection (2), (4) Temporary Sector Unprotection (5) Reset (Hardware)/Standby MBM29DL800TA/BA User Bus Operations (BYTE = VIH) CE L L L H L L L L X X OE L L L X H H VID L X X H X X WE H H H X H L A0 L H A0 X X A0 L L X X A1 L L A1 X X A1 H H X X A6 L L A6 X X A6 L L X X A9 VID VID A9 X X A9 VID VID X X DQ0 to DQ15 Code Code DOUT HIGH-Z HIGH-Z DIN X Code X HIGH-Z RESET H H H H H H H H VID L
Table 3 Operation
MBM29DL800TA/BA User Bus Operations (BYTE = VIL) CE L L L H L L L L X X OE L L L X H H VID L X X H X X WE H H H X H L DQ15/ A-1 L L A-1 X X A-1 L L X X A0 L H A0 X X A0 L L X X A1 L L A1 X X A1 H H X X A6 L L A6 X X A6 L L X X A9 VID VID A9 X X A9 VID VID X X DQ0 to DQ7 RESET Code Code DOUT HIGH-Z HIGH-Z DIN X Code X HIGH-Z H H H H H H H H VID L
Auto-Select Manufacturer Code (1) Auto-Select Device Code (1) Read (3) Standby Output Disable Write (Program/Erase) Enable Sector Protection (2), (4) Verify Sector Protection (2), (4) Temporary Sector Unprotection (5) Reset (Hardware)/Standby Legend: L = VIL, H = VIH, X = VIL or VIH,
= Pulse input. See DC Characteristics for voltage levels.
Notes: 1. Manufacturer and device codes may also be accessed via a command register write sequence. See Table 8. 2. Refer to the section on Sector Protection. 3. WE can be VIL if OE is VIL, OE at VIH initiates the write operations. 4. VCC = 3.0 V 10% 5. It is also used for the extended sector protection.
9
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
s ORDERING INFORMATION
Standard Products
Fujitsu standard products are available in several packages. The order number is formed by a combination of:
MBM29DL800
T
A
-70
PFTN
PACKAGE TYPE PFTN = 48-Pin Thin Small Outline Package (TSOP) Standard Pinout PFTR = 48-Pin Thin Small Outline Package (TSOP) Reverse Pinout PBT = 48-Ball Fine Pitch Ball Grid Array Package (FBGA:BGA-48P-M02) PBT-SF2 =48-Ball Fine Pitch Ball Grid Array Package (FBGA:BGA-48P-M12) SPEED OPTION See Product Selector Guide Device Revision BOOT CODE SECTOR ARCHITECTURE T = Top sector B = Bottom sector DEVICE NUMBER/DESCRIPTION MBM29DL800 8Mega-bit (1M x 8-Bit or 512K x 16-Bit) CMOS Flash Memory 3.0 V-only Read, Program, and Erase
10
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
s FUNCTIONAL DESCRIPTION
Simultaneous Operation
MBM29DL800TA/BA have feature, which is capability of reading data from one bank of memory while a program or erase operation is in progress in the other bank of memory (simultaneous operation), in addition to the conventional features (read, program, erase, erase-suspend read, and erase-suspend program). The bank selection can be selected by bank address (A16 to A18) with zero latency. The MBM29DL800TA/BA have two banks which contain Bank 1 (16KB, 32KB, 8KB, 8KB, 8KB, 8KB, 32KB, and 16KB) and Bank 2 (64KB x fourteen sectors). The simultaneous operation can not execute multi-function mode in the same bank. Table 4 shows combination to be possible for simultaneous operation. Table 4 Case 1 2 3 4 5 6 7 Simultaneous Operation Bank 2 Status Read mode Autoselect mode Program mode Erase mode * Read mode Read mode Read mode
Bank 1 Status Read mode Read mode Read mode Read mode Autoselect mode Program mode Erase mode *
*: An erase operation may also be supended to read from or program to a sector not being erased.
Read Mode
The MBM29DL800TA/BA have two control functions which must be satisfied in order to obtain data at the outputs. CE is the power control and should be used for a device selection. OE is the output control and should be used to gate data to the output pins if a device is selected. Address access time (tACC) is equal to the delay from stable addresses to valid output data. The chip enable access time (tCE) is the delay from stable addresses and stable CE to valid data at the output pins. The output enable access time is the delay from the falling edge of OE to valid data at the output pins. (Assuming the addresses have been stable for at least tACC-tOE time.) When reading out a data without changing addresses after power-up, it is necessary to input hardware reset or to change CE pin from "H" or "L"
Standby Mode
There are two ways to implement the standby mode on the MBM29DL800TA/BA devices, one using both the CE and RESET pins; the other via the RESET pin only. When using both pins, a CMOS standby mode is achieved with CE and RESET inputs both held at VCC 0.3 V. Under this condition the current consumed is less than 5 A max. During Embedded Algorithm operation, VCC active current (ICC2) is required even CE = "H". The device can be read with standard access time (tCE) from either of these standby modes. When using the RESET pin only, a CMOS standby mode is achieved with RESET input held at VSS 0.3 V (CE = "H" or "L"). Under this condition the current is consumed is less than 5 A max. Once the RESET pin is taken high, the device requires tRH of wake up time before outputs are valid for read access. In the standby mode the outputs are in the high impedance state, independent of the OE input. 11
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
Automatic Sleep Mode
There is a function called automatic sleep mode to restrain power consumption during read-out of MBM29DL800TA/BA data. This mode can be used effectively with an application requested low power consumption such as handy terminals. To activate this mode, MBM29DL800TA/BA automatically switch themselves to low power mode when MBM29DL800TA/BA addresses remain stably during access fine of 300 ns. It is not necessary to control CE, WE, and OE on the mode. Under the mode, the current consumed is typically 1 A (CMOS Level). During simultaneous operation, VCC active current (ICC2) is required. Since the data are latched during this mode, the data are read-out continuously. If the addresses are changed, the mode is canceled automatically and MBM29DL800TA/BA read-out the data for changed addresses.
Output Disable
With the OE input at a logic high level (VIH), output from the devices are disabled. This will cause the output pins to be in a high impedance state.
Autoselect
The autoselect mode allows the reading out of a binary code from the devices and will identify its manufacturer and type. This mode is intended for use by programming equipment for the purpose of automatically matching the devices to be programmed with its corresponding programming algorithm. This mode is functional over the entire temperature range of the devices. To activate this mode, the programming equipment must force VID (11.5 V to 12.5 V) on address pin A9. Two identifier bytes may then be sequenced from the devices outputs by toggling address A0 from VIL to VIH. All addresses are DON'T CARES except A0, A1, and A6 (A-1). (See Tables 2 and 3.) The manufacturer and device codes may also be read via the command register, for instances when the MBM29DL800TA/BA are erased or programmed in a system without access to high voltage on the A9 pin. The command sequence is illustrated in Table 8. (Refer to Autoselect Command section.) Word 0 (A0 = VIL) represents the manufacturer's code (Fujitsu = 04H) and word 1 (A0 = VIH) represents the device identifier code (MBM29DL800TA = 4AH and MBM29DL800BA = CBH for x8 mode; MBM29DL800TA = 224AH and MBM29DL800BA = 22CBH for x16 mode). These two bytes/words are given in the tables 5.1 and 5.2. All identifiers for manufactures and device will exhibit odd parity with DQ7 defined as the parity bit. In order to read the proper device codes when executing the autoselect, A1 must be VIL. (See Tables 5.1 and 5.2.) In case of applying VID on A9, since both Bank 1 and Bank 2 enters Autoselect mode, the simultenous operation can not be executed.
12
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
Table 5 .1 MBM29DL800TA/BA Sector Protection Verify Autoselect Codes Type Manufacture's Code Byte MBM29DL800TA Word Device Code Byte MBM29DL800BA Word Sector Protection *1: A-1 is for Byte mode. *2: Outputs 01H at protected sector addresses and outputs 00H at unprotected sector addresses. Table 5 .2 Expanded Autoselect Code Table Type Manufacturer's Code (B) MBM29DL800TA Device Code MBM29DL800BA
(W) 22CBH (W) 224AH
A12 to A18 X X
A6 VIL VIL
A1 VIL VIL
A0 VIL VIH
A-1*1 VIL VIL X VIL
Code (HEX) 04H 4AH 224AH CBH 22CBH 01H*2
X Sector Addresses
VIL
VIL
VIH X
VIL
VIH
VIL
VIL
Code 04H
DQ15 DQ14 DQ13 DQ12 DQ11 DQ10 DQ9 DQ8 DQ7 DQ6 DQ5 DQ4 DQ3 DQ2 DQ1 DQ0 A-1/0
0
0
0
0
0
0
0
0
0 1 1 1 1 0
0 0 0 0 0 0
0 0 0 0 0 0
0 1 1 1 1 0
1 0 0 0 0 0
0 1 1 1 1 0
0 0 0 1 1 1
4AH A-1 HI-Z HI-Z HI-Z HI-Z HI-Z HI-Z HI-Z 0 0 0 1 0 0 0 1 0 0
(B) CBH A-1 HI-Z HI-Z HI-Z HI-Z HI-Z HI-Z HI-Z 1 0
A-1/0
0 0
1 0
0 0
0 0
0 0
1 0
0 0
1 0
Sector Protection (B): Byte mode (W): Word mode
01H
13
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
Write
Device erasure and programming are accomplished via the command register. The contents of the register serve as inputs to the internal state machine. The state machine outputs dictate the function of the device. The command register itself does not occupy any addressable memory location. The register is a latch used to store the commands, along with the address and data information needed to execute the command. The command register is written by bringing WE to VIL, while CE is at VIL and OE is at VIH. Addresses are latched on the falling edge of WE or CE, whichever happens later; while data is latched on the rising edge of WE or CE, whichever happens first. Standard microprocessor write timings are used. Refer to AC Write Characteristics and the Erase/Programming Waveforms for specific timing parameters.
Sector Protection
The MBM29DL800TA/BA feature hardware sector protection. This feature will disable both program and erase operations in any number of sectors (0 through 21). The sector protection feature is enabled using programming equipment at the user's site. The devices are shipped with all sectors unprotected. Alternatively, Fujitsu may program and protect sectors in the factory prior to shiping the device. To activate this mode, the programming equipment must force VID on address pin A9 and control pin OE, (suggest VID = 11.5 V), CE = VIL, and A0 = A6 = VIL, A1 = VIH. The sector addresses (A18, A17, A16, A15, A14, A13, and A12) should be set to the sector to be protected. Tables 6 and 7 define the sector address for each of the twenty two (22) individual sectors. Programming of the protection circuitry begins on the falling edge of the WE pulse and is terminated with the rising edge of the same. Sector addresses must be held constant during the WE pulse. See Figures 16 and 25 for sector protection waveforms and algorithm. To verify programming of the protection circuitry, the programming equipment must force VID on address pin A9 with CE and OE at VIL and WE at VIH. Scanning the sector addresses (A18, A17, A16, A15, A14, A13, and A12) while (A6, A1, A0) = (0, 1, 0) will produce a logical "1" code at device output DQ0 for a protected sector. Otherwise the devices will read 00H for unprotected sector. In this mode, the lower order addresses, except for A0, A1, and A6 are DON'T CARES. Address locations with A1 = VIL are reserved for Autoselect manufacturer and device codes. A-1 requires to apply to VIL on byte mode. It is also possible to determine if a sector is protected in the system by writing an Autoselect command. Performing a read operation at the address location XX02H, where the higher order addresses (A18, A17, A16, A15, A14, A13, and A12) are the desired sector address will produce a logical "1" at DQ0 for a protected sector. See Tables 5.1 and 5.2 for Autoselect codes.
Temporary Sector Unprotection
This feature allows temporary unprotection of previously protected sectors of the MBM29DL800TA/BA devices in order to change data. The Sector Unprotection mode is activated by setting the RESET pin to high voltage (12 V). During this mode, formerly protected sectors can be programmed or erased by selecting the sector addresses. Once the 12 V is taken away from the RESET pin, all the previously protected sectors will be protected again. See Figures 17 and 26.
14
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
RESET Hardware Reset
The MBM29DL800TA/BA devices may be reset by driving the RESET pin to VIL. The RESET pin has a pulse requirement and has to be kept low (VIL) for at least 500 ns in order to properly reset the internal state machine. Any operation in the process of being executed will be terminated and the internal state machine will be reset to the read mode 20 s after the RESET pin is driven low. Furthermore, once the RESET pin goes high, the devices require an additional tRH before it will allow read access. When the RESET pin is low, the devices will be in the standby mode for the duration of the pulse and all the data output pins will be tri-stated. If a hardware reset occurs during a program or erase operation, the data at that particular location will be corrupted. Please note that the RY/BY output signal should be ignored during the RESET pulse. See Figure 12 for the timing diagram. Refer to Temporary Sector Unprotection for additional functionality.
15
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
Table 6 Sector Address Tables (MBM29DL800TA)
Sector Address Bank Sector Bank Address A18 A17 A16 A15 A14 A13 A12 SA0 SA1 SA2 SA3 SA4 SA5 SA6 Bank 2 SA7 SA8 SA9 SA10 SA11 SA12 SA13 SA14 SA15 SA16 SA17 Bank 1 SA18 SA19 SA20 SA21 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 1 X X 16/8 0 0 0 0 0 1 0 1 X 32/16 8/4 8/4 F0000H to F1FFFH F2000H to F3FFFH 78000H to 78FFFH 79000H to 79FFFH 0 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 1 1 1 1 1 1 1 0 0 1 1 0 0 1 1 1 1 1 0 1 0 1 0 1 0 0 1 0 0 1 1 0 1 1 X 0 1 8/4 8/4 X X X X X X X 0 0 X X X X X X X 0 1 X X X X X X X X X 32/16 64/32 64/32 64/32 64/32 64/32 64/32 64/32 16/8 70000H to 7FFFFH 80000H to 8FFFFH 90000H to 9FFFFH A0000H to AFFFFH B0000H to BFFFFH C0000H to CFFFFH D0000H to DFFFFH E0000H to E3FFFH 38000H to 3FFFFH 40000H to 47FFFH 48000H to 4FFFFH 50000H to 57FFFH 58000H to 5FFFFH 60000H to 67FFFH 68000H to 6FFFFH 70000H to 71FFFH 0 0 0 0 0 0 0 0 0 0 0 1 1 1 0 0 1 1 0 0 1 0 1 0 1 0 1 0 X X X X X X X X X X X X X X X X X X X X X 64/32 64/32 64/32 64/32 64/32 64/32 64/32 00000H to 0FFFFH 10000H to 1FFFFH 20000H to 2FFFFH 30000H to 3FFFFH 40000H to 4FFFFH 50000H to 5FFFFH 60000H to 6FFFFH 00000H to 07FFFH 08000H to 0FFFFH 10000H to 17FFFH 18000H to 1FFFFH 20000H to 27FFFH 28000H to 2FFFFH 30000H to 37FFFH Sector Size (Kbytes/ Kwords) (x8) Address Range (x16) Address Range
E4000H to E7FFFH, 72000H to 73FFFH, E8000H to EBFFFH 74000H to 75FFFH EC000H to EDFFFH 76000H to 76FFFH EE000H to EFFFFH 77000H to 77FFFH
F4000H to F7FFFH, 7A000H to 7BFFFH, F8000H to FBFFFH 7C000H to 7DFFFH FC000H to FFFFFH 7E000H to 7FFFFH
Note: The address range is A18: A-1 if in byte mode (BYTE = VIL). The address range is A18: A0 if in word mode (BYTE = VIH).
16
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
Table 7 Sector Address Tables (MBM29DL800BA)
Sector Address Bank Sector Bank Address A18 A17 A16 A15 A14 A13 A12 SA21 SA20 SA19 SA18 SA17 SA16 SA15 Bank 2 SA14 SA13 SA12 SA11 SA10 SA9 SA8 SA7 SA6 SA5 SA4 Bank 1 SA3 SA2 SA1 SA0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 X X 16/8 1 1 1 1 1 0 1 0 X 32/16 8/4 8/4 0E000H to 0FFFFH 0C000H to 0DFFFH 07000H to 07FFFH 06000H to 06FFFH 1 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 0 1 1 0 0 1 1 0 0 0 0 0 1 0 1 0 1 0 1 1 0 1 1 0 0 1 0 0 X 1 0 8/4 8/4 X X X X X X X 1 1 X X X X X X X 1 0 X X X X X X X X X 32/16 64/32 64/32 64/32 64/32 64/32 64/32 64/32 16/8 80000H to 8FFFFH 70000H to 7FFFFH 60000H to 6FFFFH 50000H to 5FFFFH 40000H to 4FFFFH 30000H to 3FFFFH 20000H to 2FFFFH 1C000H to 1FFFFH 40000H to 47FFFH 38000H to 3FFFFH 30000H to 37FFFH 28000H to 2FFFFH 20000H to 27FFFH 18000H to 1FFFFH 10000H to 17FFFH 0E000H to 0FFFFH 1 1 1 1 1 1 1 1 1 1 1 0 0 0 1 1 0 0 1 1 0 1 0 1 0 1 0 1 X X X X X X X X X X X X X X X X X X X X X 64/32 64/32 64/32 64/32 64/32 64/32 64/32 F0000H to FFFFFH E0000H to EFFFFH D0000H to DFFFFH C0000H to CFFFFH B0000H to BFFFFH A0000H to AFFFFH 90000H to 9FFFFH 78000H to 7FFFFH 70000H to 77FFFH 68000H to 6FFFFH 60000H to 67FFFH 58000H to 5FFFFH 50000H to 57FFFH 48000H to 4FFFFH Sector Size (Kbytes/ Kwords) (x8) Address Range (x16) Address Range
14000H to 17FFFH, 0A000H to 0BFFFH, 18000H to 1BFFFH 0C000H to 0DFFFH 12000H to 13FFFH 10000H to 11FFFH 09000H to 09FFFH 08000H to 08FFFH
08000H to 0BFFFH, 04000H to 05FFFH, 04000H to 07FFFH 02000H to 03FFFH 00000H to 03FFFH 00000H to 01FFFH
Note: The address range is A18: A-1 if in byte mode (BYTE = VIL). The address range is A18: A0 if in word mode (BYTE = VIH).
17
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
Table 8 Command Sequence
Read/Reset Read/Reset Bus Write Cycles Req'd
MBM29DL800TA/BA Command Definitions
First Bus Second Bus Third Bus Fourth Bus Fifth Bus Sixth Bus Write Cycle Write Cycle Write Cycle Read/Write Write Cycle Write Cycle Cycle Addr. Data Addr. Data Addr. Data Addr. Data Addr. Data Addr. Data XXXH F0H -- -- -- -- F0H -- RA -- RD -- -- -- -- -- -- -- --
Word Byte Word Byte Word
1 3
Autoselect
3
Byte Word Byte Word Byte Word Byte
Program
4 6 6 1 1 3 2 2 4
Chip Erase
Sector Erase
Erase Suspend Erase Resume
Set to Fast Mode Fast Program *1 Reset from Fast Mode *1 Extended Sector Protect*2
Word Byte Word Byte Word Byte Word Byte
555H 2AAH 555H AAH 55H AAAH 555H AAAH (BA) 555H 2AAH 555H AAH 55H (BA) AAAH 555H AAAH 555H 2AAH 555H AAH 55H AAAH 555H AAAH 555H 2AAH 555H AAH 55H AAAH 555H AAAH 555H 2AAH 555H AAH 55H AAAH 555H AAAH BA B0H -- -- -- BA 30H -- -- -- 555H 2AAH 555H AAH 55H AAAH 555H AAAH XXXH A0H PA PD -- XXXH BA XXXH F0H 90H -- BA XXXH *3 XXXH 60H SPA 60H SPA
90H
--
--
--
--
--
--
A0H 80H
PA
PD
--
--
--
--
555H 2AAH 555H AAH 55H 10H AAAH 555H AAAH 555H 2AAH 80H AAH 55H SA 30H AAAH 555H -- -- -- -- -- -- -- -- -- -- -- -- -- -- 20H -- -- 40H -- -- -- SPA -- -- -- SD -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
*1: This command is valid while Fast Mode. *2: This command is valid while RESET=VID. *3: This data "00H" is also acceptable. Notes: 1. Address bits A12 to A18 = X = "H" or "L" for all address commands except or Program Address (PA), Sector Address (SA), and Bank Address (BA). 2. Bus operations are defined in Tables 2 and 3. 3. RA = Address of the memory location to be read PA = Address of the memory location to be programmed Addresses are latched on the falling edge of the write pulse. SA = Address of the sector to be erased. The combination of A18, A17, A16, A15, A14, A13, and A12 will uniquely select any sector. BA = Bank Address (A16 to A18) 4. RD = Data read from location RA during read operation. PD = Data to be programmed at location PA. Data is latched on the falling edge of write pulse. 5. SPA =Sector address to be protected. Set sector address (SA) and (A6, A1, A0) = (0, 1, 0). SD = Sector protection verify data. Output 01H at protected sector addresses and output 00H at unprotected sector addresses. 6. The system should generate the following address patterns: Word Mode: 555H or 2AAH to addresses A0 to A11 Byte Mode: AAAH or 555H to addresses A-1 and A0 to A11 7. Both Read/Reset commands are functionally equivalent, resetting the device to the read mode. 18
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
Command Definitions
Device operations are selected by writing specific address and data sequences into the command register. Writing incorrect address and data values or writing them in the improper sequence will reset the devices to the read mode. Some commands are required Bank Address (BA) input. When command sequences are inputed to bank being read, the commands have priority than reading. Table 8 defines the valid register command sequences. Note that the Erase Suspend (B0H) and Erase Resume (30H) commands are valid only while the Sector Erase operation is in progress. Moreover both Read/Reset commands are functionally equivalent, resetting the device to the read mode. Please note that commands are always written at DQ0 to DQ7 and DQ8 to DQ15 bits are ignored.
Read/Reset Command
In order to return from Autoselect mode or Exceeded Timing Limits (DQ5 = 1) to Read/Reset mode, the Read/ Reset operation is initiated by writing the Read/Reset command sequence into the command register. Microprocessor read cycles retrieve array data from the memory. The devices remain enabled for reads until the command register contents are altered. The devices will automatically power-up in the Read/Reset state. In this case, a command sequence is not required to read data. Standard microprocessor read cycles will retrieve array data. This default value ensures that no spurious alteration of the memory content occurs during the power transition. Refer to the AC Read Characteristics and Waveforms for the specific timing parameters.
Autoselect Command
Flash memories are intended for use in applications where the local CPU alters memory contents. As such, manufacture and device codes must be accessible while the devices reside in the target system. PROM programmers typically access the signature codes by raising A9 to a high voltage. However, multiplexing high voltage onto the address lines is not generally desired system design practice. The device contains an Autoselect command operation to supplement traditional PROM programming methodology. The operation is initiated by writing the Autoselect command sequence into the command register. The Autoselect command sequence is initiated by first writing two unlock cycles. This is followed by a third write cycle that contains the bank address (BA) and the Autoselect command. Then the manufacture and device codes can be read from the bank, and an actual data of memory cell can be read from the another bank. Following the command write, a read cycle from address (BA)00H retrieves the manufacture code of 04H. A read cycle from address (BA)01H for x16((BA)02H for x8) returns the device code (MBM29DL800TA = 4AH and MBM29DL800BA = CBH for x8 mode; MBM29DL800TA = 224AH and MBM29DL800BA = 22CBH for x16 mode). (See Tables 5.1 and 5.2.) All manufacturer and device codes will exhibit odd parity with DQ7 defined as the parity bit. Sector state (protection or unprotection) will be informed by address (BA)02H for x16 ((BA)04H for x8). Scanning the sector addresses (A18, A17, A16, A15, A14, A13, and A12) while (A6, A1, A0) = (0, 1, 0) will produce a logical "1" at device output DQ0 for a protected sector. The programming verification should be performed by verify sector protection on the protected sector. (See Tables 2 and 3.) The manufacture and device codes can be allowed reading from selected bank. To read the manufacture and device codes and sector protection status from non-selected bank, it is necessary to write Read/Reset command sequence into the register and then Autoselect command should be written into the bank to be read. If the software (program code) for Autoselect command is stored into the Frash memory, the device and manufacture codes should be read from the other bank where is not contain the software.
19
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
To terminate the operation, it is necessary to write the Read/Reset command sequence into the register, and also to write the Autoselect command during the operation, execute it after writing Read/Reset command sequence.
Byte/Word Programming
The devices are programmed on a byte-by-byte (or word-by-word) basis. Programming is a four bus cycle operation. There are two "unlock" write cycles. These are followed by the program set-up command and data write cycles. Addresses are latched on the falling edge of CE or WE, whichever happens later and the data is latched on the rising edge of CE or WE, whichever happens first. The rising edge of CE or WE (whichever happens first) begins programming. Upon executing the Embedded Program Algorithm command sequence, the system is not required to provide further controls or timings. The device will automatically provide adequate internally generated program pulses and verify the programmed cell margin. The system can determine the status of the program operation by using DQ7 (Data Polling), DQ6 (Toggle Bit), or RY/BY. The Data Polling and Toggle Bit must be performed at the memory location which is being programmed. The automatic programming operation is completed when the data on DQ7 is equivalent to data written to this bit at which time the devices return to the read mode and addresses are no longer latched. (See Table 9, Hardware Sequence Flags.) Therefore, the devices require that a valid address to the devices be supplied by the system at this particular instance of time. Hence, Data Polling must be performed at the memory location which is being programmed. Any commands written to the chip during this period will be ignored. If hardware reset occurs during the programming operation, it is impossible to guarantee the data are being written. Programming is allowed in any sequence and across sector boundaries. Beware that a data "0" cannot be programmed back to a "1". Attempting to do so may either hang up the device or result in an apparent success according to the data polling algorithm but a read from Read/Reset mode will show that the data is still "0". Only erase operations can convert "0"s to "1"s. Figure 21 illustrates the Embedded ProgramTM Algorithm using typical command strings and bus operations.
Chip Erase
Chip erase is a six bus cycle operation. There are two "unlock" write cycles. These are followed by writing the "set-up" command. Two more "unlock" write cycles are then followed by the chip erase command. Chip erase does not require the user to program the device prior to erase. Upon executing the Embedded Erase Algorithm command sequence the devices will automatically program and verify the entire memory for an all zero data pattern prior to electrical erase (Preprogram function). The system is not required to provide any controls or timings during these operations. The system can determine the status of the erase operation by using DQ7 (Data Polling), DQ6 (Toggle Bit), or RY/BY. The chip erase begins on the rising edge of the last CE or WE, whichever happens first in the command sequence and terminates when the data on DQ7 is "1" (See Write Operation Status section.) at which time the device returns to read the mode. Chip Erase Time; Sector Erase Time x All sectors + Chip Program Time (Preprogramming) Figure 22 illustrates the Embedded EraseTM Algorithm using typical command strings and bus operations.
20
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
Sector Erase
Sector erase is a six bus cycle operation. There are two "unlock" write cycles. These are followed by writing the "set-up" command. Two more "unlock" write cycles are then followed by the Sector Erase command. The sector address (any address location within the desired sector) is latched on the falling edge of CE or WE whichever happens later, while the command (Data=30H) is latched on the rising edge of CE or WE which happens first. After time-out of 50 s from the rising edge of the last sector erase command, the sector erase operation will begin. Multiple sectors may be erased concurrently by writing the six bus cycle operations on Table 8. This sequence is followed with writes of the Sector Erase command to addresses in other sectors desired to be concurrently erased. The time between writes must be less than 50 s otherwise that command will not be accepted and erasure will start. It is recommended that processor interrupts be disabled during this time to guarantee this condition. The interrupts can be re-enabled after the last Sector Erase command is written. A time-out of 50 s from the rising edge of last CE or WE whichever happens first will initiate the execution of the Sector Erase command(s). If another falling edge of CE or WE, whichever happens first occurs within the 50 s time-out window the timer is reset. (Monitor DQ3 to determine if the sector erase timer window is still open, see section DQ3, Sector Erase Timer.) Any command other than Sector Erase or Erase Suspend during this time-out period will reset the devices to the read mode, ignoring the previous command string. Resetting the devices once execution has begun will corrupt the data in the sector. In that case, restart the erase on those sectors and allow them to complete. (Refer to the Write Operation Status section for Sector Erase Timer operation.) Loading the sector erase buffer may be done in any sequence and with any number of sectors (0 to 21). Sector erase does not require the user to program the devices prior to erase. The devices automatically program all memory locations in the sector(s) to be erased prior to electrical erase (Preprogram function). When erasing a sector or sectors the remaining unselected sectors are not affected. The system is not required to provide any controls or timings during these operations. The system can determine the status of the erase operation by using DQ7 (Data Polling), DQ6 (Toggle Bit), or RY/BY. The sector erase begins after the 50 s time out from the rising edge of CE or WE whichever happens first for the last sector erase command pulse and terminates when the data on DQ7 is "1" (See Write Operation Status section.) at which time the devices return to the read mode. Data polling and Toggle Bit must be performed at an address within any of the sectors being erased. Multiple Sector Erase Time; [Sector Erase Time + Sector Program Time (Preprogramming)] x Number of Sector Erase In case of multiple sector erase across bank boundaries, a read from bank (read-while-erase) can not performe. Figure 22 illustrates the Embedded EraseTM Algorithm using typical command strings and bus operations.
Erase Suspend/Resume
The Erase Suspend command allows the user to interrupt a Sector Erase operation and then perform data reads from or programs to a sector not being erased. This command is applicable ONLY during the Sector Erase operation which includes the time-out period for sector erase. The Erase Suspend command will be ignored if written during the Chip Erase operation or Embedded Program Algorithm. Writting the Erase Suspend command (B0H) during the Sector Erase time-out results in immediate termination of the time-out period and suspension of the erase operation. Writing the Erase Resume command (30H) resumes the erase operation. The bank addresses of sector being erasing or suspending should be set when writting the Erase Suspend or Erase Resume command.
21
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
When the Erase Suspend command is written during the Sector Erase operation, the device will take a maximum of 20 s to suspend the erase operation. When the devices have entered the erase-suspended mode, the RY/ BY output pin will be at Hi-Z and the DQ7 bit will be at logic "1", and DQ6 will stop toggling. The user must use the address of the erasing sector for reading DQ6 and DQ7 to determine if the erase operation has been suspended. Further writes of the Erase Suspend command are ignored. When the erase operation has been suspended, the devices default to the erase-suspend-read mode. Reading data in this mode is the same as reading from the standard read mode except that the data must be read from sectors that have not been erase-suspended. Successively reading from the erase-suspended sector while the device is in the erase-suspend-read mode will cause DQ2 to toggle. (See the section on DQ2.) After entering the erase-suspend-read mode, the user can program the device by writing the appropriate command sequence for Program. This program mode is known as the erase-suspend-program mode. Again, programming in this mode is the same as programming in the regular Program mode except that the data must be programmed to sectors that are not erase-suspended. Successively reading from the erase-suspended sector while the devices are in the erase-suspend-program mode will cause DQ2 to toggle. The end of the erasesuspended Program operation is detected by the RY/BY output pin, Data polling of DQ7 or by the Toggle Bit I (DQ6) which is the same as the regular Program operation. Note that DQ7 must be read from the Program address while DQ6 can be read from any address within bank being erase-suspended. To resume the operation of Sector Erase, the Resume command (30H) should be written to the bank being erase suspended. Any further writes of the Resume command at this point will be ignored. Another Erase Suspend command can be written after the chip has resumed erasing.
Extended Command
(1) Fast Mode MBM29DL800TA/BA has Fast Mode function. This mode dispenses with the initial two unclock cycles required in the standard program command sequence by writing Fast Mode command into the command register. In this mode, the required bus cycle for programming is two cycles instead of four bus cycles in standard program command. (Do not write erase command in this mode.) The read operation is also executed after exiting this mode. To exit this mode, it is necessary to write Fast Mode Reset command into the command register. The first cycle must contain the bank address. (Refer to the Figure 28 Extended algorithm.) The VCC active current is required even CE = VIH during Fast Mode. (2) Fast Programming During Fast Mode, the programming can be executed with two bus cycles operation. The Embedded Program Algorithm is executed by writing program set-up command (A0H) and data write cycles (PA/PD). (Refer to the Figure 28 Extended algorithm.) (3) Extended Sector Protection In addition to normal sector protection, the MBM29DL800TA/BA has Extended Sector Protection as extended function. This function enable to protect sector by forcing VID on RESET pin and write a commnad sequence. Unlike conventional procedure, it is not necessary to force VID and control timing for control pins. The only RESET pin requires VID for sector protection in this mode. The extended sector protect requires VID on RESET pin. With this condition, the operation is initiated by writing the set-up command (60H) into the command register. Then, the sector addresses pins (A18, A17, A16, A15, A14, A13 and A12) and (A6, A1, A0) = (0, 1, 0) should be set to the sector to be protected (recommend to set VIL for the other addresses pins), and write extended sector protect command (60H). A sector is typically protected in 150 s. To verify programming of the protection circuitry, the sector addresses pins (A18, A17, A16, A15, A14, A13 and A12) and (A6, A1, A0) = (0, 1, 0) should be set and write a command (40H). Following the command write, a logical "1" at device output DQ0 will produce for protected sector in the read operation. If the output data is logical "0", please repeat to write extended sector protect command (60H) again. To terminate the operation, it is necessary to set RESET pin to VIH.
22
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
Write Operation Status
Detailed in Table 9 are all the status flags that can determine the status of the bank for the current mode operation. The read operation from the bank where is not operate Embedded Algorithm returns a data of memory cell. These bits offer a method for determining whether a Embedded Algorithm is completed properly. The information on DQ2 is address sensitive. This means that if an address from an erasing sector is consectively read, then the DQ2 bit will toggle. However, DQ2 will not toggle if an address from a non-erasing sector is consectively read. This allows the user to determine which sectors are erasing and which are not. The status flag is not output from bank (non-busy bank) not executing Embedded Algorithm. For example, there is bank (busy bank) which is now executing Embedded Algorithm. When the read sequence is [1] , [2] , [3] , the DQ6 is toggling in the case of [1] and [3]. In case of [2], the data of memory cell is outputted. In the erase-suspend read mode with the same read sequence, DQ6 will not be toggled in the [1] and [3]. In the erase suspend read mode, DQ2 is toggled in the [1] and [3]. In case of [2], the data of memory cell is outputted.
Table 9 Status Embedded Program Algorithm Embedded Erase Algorithm In Progress
Hardware Sequence Flags DQ7 DQ7 0 1 Data DQ7 DQ7 0 DQ7 DQ6 Toggle Toggle 1 Data Toggle Toggle Toggle Toggle DQ5 0 0 0 DQ3 0 1 0 DQ2 1 Toggle (Note 1) Toggle Data 1 (Note 1) 1 N/A N/A
Erase Suspend Read (Erase Suspended Sector) Erase Erase Suspend Read Suspended (Non-Erase Suspended Sector) Mode Erase Suspend Program (Non-Erase Suspended Sector) Embedded Program Algorithm
Data Data 0 1 1 1 0 0 1 0
Embedded Erase Algorithm Exceeded Time Limits Erase Erase Suspend Program Suspended (Non-Erase Suspended Sector) Mode
Notes: 1. Successive reads from the erasing or erase-suspend sector will cause DQ2 to toggle. Reading from non-erase suspend sector address will indicate logic "1" at the DQ2 bit. 2. DQ0 and DQ1 are reserve pins for future use. 3. DQ4 is Fujitsu internal use only.
23
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
DQ7 Data Polling
The MBM29DL800TA/BA devices feature Data Polling as a method to indicate to the host that the Embedded Algorithms are in progress or completed. During the Embedded Program Algorithm an attempt to read the devices will produce the complement of the data last written to DQ7. Upon completion of the Embedded Program Algorithm, an attempt to read the device will produce the true data last written to DQ7. During the Embedded Erase Algorithm, an attempt to read the device will produce a "0" at the DQ7 output. Upon completion of the Embedded Erase Algorithm an attempt to read the device will produce a "1" at the DQ7 output. The flowchart for Data Polling (DQ7) is shown in Figure 23. For programming, the Data Polling is valid after the rising edge of fourth write pulse in the four write pulse sequence. For chip erase and sector erase, the Data Polling is valid after the rising edge of the sixth write pulse in the six write pulse sequence. Data Polling must be performed at sector address within any of the sectors being erased and not a protected sector. Otherwise, the status may not be valid. If a program address falls within a protected sector, Data Polling on DQ7 is active for approximately 1 s, then that bank returns to the read mode. After an erase command sequence is written, if all sectors selected for erasing are protected, Data Polling on DQ7 is active for approximately 100 s, then the bank returns to read mode. Once the Embedded Algorithm operation is close to being completed, the MBM29DL800TA/BA data pins (DQ7) may change asynchronously while the output enable (OE) is asserted low. This means that the devices are driving status information on DQ7 at one instant of time and then that byte's valid data at the next instant of time. Depending on when the system samples the DQ7 output, it may read the status or valid data. Even if the device has completed the Embedded Algorithm operation and DQ7 has a valid data, the data outputs on DQ0 to DQ6 may be still invalid. The valid data on DQ0 to DQ7 will be read on the successive read attempts. The Data Polling feature is only active during the Embedded Programming Algorithm, Embedded Erase Algorithm or sector erase time-out. (See Table 9.) See Figure 9 for the Data Polling timing specifications and diagrams.
DQ6 Toggle Bit I
The MBM29DL800TA/BA also feature the "Toggle Bit I" as a method to indicate to the host system that the Embedded Algorithms are in progress or completed. During an Embedded Program or Erase Algorithm cycle, successive attempts to read (OE toggling) data from the devices will result in DQ6 toggling between one and zero. Once the Embedded Program or Erase Algorithm cycle is completed, DQ6 will stop toggling and valid data will be read on the next successive attempts. During programming, the Toggle Bit I is valid after the rising edge of the fourth write pulse in the four write pulse sequence. For chip erase and sector erase, the Toggle Bit I is valid after the rising edge of the sixth write pulse in the six write pulse sequence. The Toggle Bit I is active during the sector time out. In programming, if the sector being written to is protected, the toggle bit will toggle for about 2 s and then stop toggling without the data having changed. In erase, the devices will erase all the selected sectors except for the ones that are protected. If all selected sectors are protected, the chip will toggle the toggle bit for about 100 s and then drop back into read mode, having changed none of the data. Either CE or OE toggling will cause the DQ6 to toggle. In addition, an Erase Suspend/Resume command will cause the DQ6 to toggle.
24
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
The system can use DQ6 to determine whether a sector is actively erasing or is erase-suspended. When a bank is actively erasing (that is, the Embedded Erase Algorithm is in progress), DQ6 toggles. When a bank enters the Erase Suspend mode, DQ6 stops toggling. Successive read cycles during the erase-suspend-program cause DQ6 to toggle. To operate toggle bit function properly, CE or OE must be high when bank address is changed. See Figure 10 for the Toggle Bit I timing specifications and diagrams.
DQ5 Exceeded Timing Limits
DQ5 will indicate if the program or erase time has exceeded the specified limits (internal pulse count). Under these conditions DQ5 will produce a "1". This is a failure condition which indicates that the program or erase cycle was not successfully completed. Data Polling is the only operating function of the devices under this condition. The CE circuit will partially power down the device under these conditions (to approximately 2 mA). The OE and WE pins will control the output disable functions as described in Tables 2 and 3. The DQ5 failure condition may also appear if a user tries to program a non blank location without erasing. In this case the devices lock out and never complete the Embedded Algorithm operation. Hence, the system never reads a valid data on DQ7 bit and DQ6 never stops toggling. Once the devices have exceeded timing limits, the DQ5 bit will indicate a "1." Please note that this is not a device failure condition since the devices were incorrectly used. If this occurs, reset the device with command sequence.
DQ3 Sector Erase Timer
After the completion of the initial sector erase command sequence the sector erase time-out will begin. DQ3 will remain low until the time-out is complete. Data Polling and Toggle Bit are valid after the initial sector erase command sequence. If Data Polling or the Toggle Bit I indicates the device has been written with a valid erase command, DQ3 may be used to determine if the sector erase timer window is still open. If DQ3 is high ("1") the internally controlled erase cycle has begun; attempts to write subsequent commands to the device will be ignored until the erase operation is completed as indicated by Data Polling or Toggle Bit I. If DQ3 is low ("0"), the device will accept additional sector erase commands. To insure the command has been accepted, the system software should check the status of DQ3 prior to and following each subsequent Sector Erase command. If DQ3 were high on the second status check, the command may not have been accepted. See Table 9: Hardware Sequence Flags.
DQ2 Toggle Bit II
This toggle bit II, along with DQ6, can be used to determine whether the devices are in the Embedded Erase Algorithm or in Erase Suspend. Successive reads from the erasing sector will cause DQ2 to toggle during the Embedded Erase Algorithm. If the devices are in the erase-suspended-read mode, successive reads from the erase-suspended sector will cause DQ2 to toggle. When the devices are in the erase-suspended-program mode, successive reads from the byte address of the non-erase suspended sector will indicate a logic "1" at the DQ2 bit. DQ6 is different from DQ2 in that DQ6 toggles only when the standard program or Erase, or Erase Suspend Program operation is in progress. The behavior of these two status bits, along with that of DQ7, is summarized as follows: 25
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
For example, DQ2 and DQ6 can be used together to determine if the erase-suspend-read mode is in progress. (DQ2 toggles while DQ6 does not.) See also Table 9 and Figure 19. Furthermore, DQ2 can also be used to determine which sector is being erased. When the device is in the erase mode, DQ2 toggles if this bit is read from an erasing sector. To operate toggle bit function properly, CE or OE must be high when bank address is changed. Mode Program Erase Erase-Suspend Read (Erase-Suspended Sector) Erase-Suspend Program DQ7 DQ7 0 1 DQ7 DQ6 Toggle Toggle 1 Toggle DQ2 1 Toggle (Note) Toggle 1 (Note)
Note: Successive reads from the erasing or erase-suspend sector will cause DQ2 to toggle. Reading from nonerase suspend sector address will indicate logic "1" at the DQ2 bit.
RY/BY Ready/Busy
The MBM29DL800TA/BA provide a RY/BY open-drain output pin as a way to indicate to the host system that the Embedded Algorithms are either in progress or has been completed. If the output is low, the devices are busy with either a program or erase operation. If the output is high, the devices are ready to accept any read/ write or erase operation. When the RY/BY pin is low, the devices will not accept any additional program or erase commands. If the MBM29DL800TA/BA are placed in an Erase Suspend mode, the RY/BY output will be high. During programming, the RY/BY pin is driven low after the rising edge of the fourth write pulse. During an erase operation, the RY/BY pin is driven low after the rising edge of the sixth write pulse. The RY/BY pin will indicate a busy condition during the RESET pulse. Refer to Figure 11 and 12 for a detailed timing diagram. The RY/BY pin is pulled high in standby mode. Since this is an open-drain output, RY/BY pins can be tied together in parallel with a pull-up resistor to VCC.
Byte/Word Configuration
The BYTE pin selects the byte (8-bit) mode or word (16-bit) mode for the MBM29DL800TA/BA devices. When this pin is driven high, the devices operate in the word (16-bit) mode. The data is read and programmed at DQ0 to DQ15. When this pin is driven low, the devices operate in byte (8-bit) mode. Under this mode, the DQ15/A-1 pin becomes the lowest address bit and DQ8 to DQ14 bits are tri-stated. However, the command bus cycle is always an 8-bit operation and hence commands are written at DQ0 to DQ7 and the DQ8 to DQ15 bits are ignored. Refer to Figures 13, 14 and 15 for the timing diagram.
Data Protection
The MBM29DL800TA/BA are designed to offer protection against accidental erasure or programming caused by spurious system level signals that may exist during power transitions. During power up the devices automatically reset the internal state machine in the Read mode. Also, with its control register architecture, alteration of the memory contents only occurs after successful completion of specific multi-bus cycle command sequences. The devices also incorporate several features to prevent inadvertent write cycles resulting form VCC power-up and power-down transitions or system noise.
26
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
Low VCC Write Inhibit
To avoid initiation of a write cycle during VCC power-up and power-down, a write cycle is locked out for VCC less than 2.3 V (typically 2.4 V). If VCC < VLKO, the command register is disabled and all internal program/erase circuits are disabled. Under this condition the device will reset to the read mode. Subsequent writes will be ignored until the VCC level is greater than VLKO. It is the users responsibility to ensure that the control pins are logically correct to prevent unintentional writes when VCC is above 2.3 V. If Embedded Erase Algorithm is interrupted, there is possibility that the erasing sector(s) cannot be used.
Write Pulse "Glitch" Protection
Noise pulses of less than 5 ns (typical) on OE, CE, or WE will not initiate a write cycle.
Logical Inhibit
Writing is inhibited by holding any one of OE = VIL, CE = VIH, or WE = VIH. To initiate a write cycle CE and WE must be a logical zero while OE is a logical one.
Power-Up Write Inhibit
Power-up of the devices with WE = CE = VIL and OE = VIH will not accept commands on the rising edge of WE. The internal state machine is automatically reset to the read mode on power-up.
27
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
s ABSOLUTE MAXIMUM RATINGS
Storage Temperature .................................................................................................. -55C to +125C Ambient Temperature with Power Applied .................................................................. -40C to +85C Voltage with respect to Ground All pins except A9, OE, RESET (Note 1) ................... -0.5 V to VCC+0.5 V VCC (Note 1) ................................................................................................................ -0.5 V to +5.5 V A9, OE, and RESET (Note 2) ...................................................................................... -0.5 V to +13.0 V Notes: 1. Minimum DC voltage on input or I/O pins are -0.5 V. During voltage transitions, inputs may negative overshoot VSS to -2.0 V for periods of up to 20 ns. Maximum DC voltage on output and I/O pins are VCC +0.5 V. During voltage transitions, outputs may positive overshoot to VCC +2.0 V for periods of up to 20 ns. 2. Minimum DC input voltage on A9, OE and RESET pins are -0.5 V. During voltage transitions, A9, OE and RESET pins may negative overshoot VSS to -2.0 V for periods of up to 20 ns. Maximum DC input voltage on A9, OE and RESET pins are +13.0 V which may positive overshoot to 14.0 V for periods of up to 20 ns. when VCC is applied. WARNING: Semiconductor devices can be permanently damaged by application of stress (voltage, current, temperature, etc.) in excess of absolute maximum ratings. Do not exceed these ratings.
s RECOMMENDED OPERATING RANGES
Ambient Temperature (TA) ........................................................................................... -40C to +85C VCC Supply Voltages MBM29DL800TA/BA-70 ........................................................................................... +3.0 V to +3.6 V MBM29DL800TA/BA-90/-12..................................................................................... +2.7 V to +3.6 V Operating ranges define those limits between which the functionality of the devices are guaranteed. WARNING: The recommended operating conditions are required in order to ensure the normal operation of the semiconductor device. All of the device's electrical characteristics are warranted when the device is operated within these ranges. Always use semiconductor devices within their recommended operating conditionranges. Operation outside these ranges may adversely affect reliability and could result in device failure. No warranty is made with respect to uses, operating conditions, or combinations not represented on the data sheet. Users considering application outside the listed conditions are advised to contact their FUJITSU representatives beforehand.
28
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
s MAXIMUM OVERSHOOT
+0.6 V -0.5 V -2.0 V
20 ns
20 ns
20 ns
Figure 1
Maximum Negative Overshoot Waveform
20 ns
V CC +2.0 V V CC +0.5 V +2.0 V
20 ns 20 ns
Figure 2
Maximum Positive Overshoot Waveform 1
20 ns
+14.0 V +13.0 V V CC +0.5 V
20 ns 20 ns
*: This waveform is applied for A9, OE, and RESET.
Figure 3
Maximum Positive Overshoot Waveform 2
29
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
s DC CHARACTERISTICS
Parameter Symbol ILI ILO ILIT Parameter Description Input Leakage Current Output Leakage Current A9, OE, RESET Inputs Leakage Current Test Conditions VIN = VSS to VCC, VCC = VCC Max. VOUT = VSS to VCC, VCC = VCC Max. VCC = VCC Max. A9, OE, RESET = 12.5 V CE = VIL, OE = VIH, f=10 MHz ICC1 VCC Active Current (Note 1) CE = VIL, OE = VIH, f=5 MHz ICC2 ICC3 ICC4 VCC Active Current (Note 2) VCC Current (Standby) VCC Current (Standby, Reset) CE = VIL, OE = VIH VCC = VCC Max., CE = VCC 0.3 V, RESET = VCC 0.3 V VCC = VCC Max., RESET = VSS 0.3 V Byte -- Word -- -- -- 10 35 5 5 mA A A 8 mA Byte -- Word 20 Min. -1.0 -1.0 -- Max. +1.0 +1.0 35 18 mA Unit A A A
ICC5
VCC = VCC Max., CE = VSS 0.3 V, VCC Current RESET = VCC 0.3 V (Automatic Sleep Mode) (Note 3) VIN = VCC 0.3 V or VSS 0.3 V VCC Active Current (Note 5) (Read-While-Program) VCC Active Current (Note 5) (Read-While-Erase) VCC Active Current (Erase-Suspend-Program) Input Low Level Input High Level Voltage for Autoselect and Sector Protection (A9, OE, RESET) (Note 4) Output Low Voltage Level Output High Voltage Level Byte CE = VIL, OE = VIH Word Byte CE = VIL, OE = VIH Word CE = VIL, OE = VIH -- -- -- IOL = 4.0 mA, VCC = VCC Min. IOH = -2.0 mA, VCC = VCC Min. IOH = -100 A --
-- -- -- -- -- -- -0.5 2.0 11.5 -- 2.4 VCC-0.4 2.3
5 45
A
ICC6
mA 45 45 mA 45 35 0.6 VCC+0.3 12.5 0.45 -- -- 2.5 mA V V V V V V V
ICC7 ICC8 VIL VIH VID VOL VOH1 VOH2 VLKO Notes: 1. 2. 3. 4. 5. 30
Low VCC Lock-Out Voltage
The ICC current listed includes both the DC operating current and the frequency dependent component. ICC active while Embedded Algorithm (program or erase) is in progress. Automatic sleep mode enables the low power mode when address remain stable for 300 ns. Applicable for only VCC applying. Embedded Algorithm (program or erase) is in progress. (@5 MHz)
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
s AC CHARACTERISTICS
* Read Only Operations Characteristics Parameter Symbols JEDEC tAVAV tAVQV tELQV tGLQV tEHQZ tGHQZ tAXQX -- -- Standard tRC tACC tCE tOE tDF tDF tOH tREADY tELFL tELFH Read Cycle Time Address to Output Delay Chip Enable to Output Delay Output Enable to Output Delay Chip Enable to Output High-Z Output Enable to Output High-Z Output Hold Time From Addresses, CE or OE, Whichever Occurs First RESET Pin Low to Read Mode CE or BYTE Switching Low or High -- CE = VIL OE = VIL OE = VIL -- -- -- -- -- -- Min. Max. Max. Max. Max. Max. Min. Max. Max. 70 70 90 30 25 25 0 20 5 90 90 90 35 30 30 0 20 5 120 120 120 50 30 30 0 20 5 ns ns ns ns ns ns ns s ns -70 -90 (Note) (Note) -12 (Note) Unit
Description
Test Setup
Note: Test Conditions: Output Load: 1 TTL gate and 30 pF (MBM29DL800TA/BA-70) 1 TTL gate and 100 pF (MBM29DL800TA/BA-90/-12) Input rise and fall times: 5 ns Input pulse levels: 0.0 V to 3.0 V Timing measurement reference level Input: 1.5 V Output:1.5 V
3.3 V IN3064 or Equivalent Device Under Test 6.2 k CL Diodes = IN3064 or Equivalent
2.7 k
Notes: CL = 30 pF including jig capacitance (MBM29LV800TA/BA-90) CL = 100 pF including jig capacitance (MBM29LV800TA/BA-10/-12)
Figure 4
Test Conditions
31
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
* Write/Erase/Program Operations Parameter Symbols Description JEDEC tAVAV tAVWL -- tWLAX -- tDVWH tWHDX -- -- -- tGHWL tGHEL tELWL tWLEL tWHEH tEHWH tWLWH tELEH tWHWL tEHEL tWHWH1 tWHWH2 -- -- -- -- -- Standard tWC tAS tASO tAH tAHT tDS tDH tOEH tCEPH tOEPH tGHWL tGHEL tCS tWS tCH tWH tWP tCP tWPH tCPH tWHWH1 tWHWH2 tVCS tVIDR tVLHT tWPP tOESP Write Cycle Time Address Setup Time Address Setup Time to OE Low During Toggle Bit Polling Address Hold Time Address Hold Time from CE or OE High During Toggle Bit Polling Data Setup Time Data Hold Time Output Enable Hold Time Read Toggle and Data Polling Min. Min. Min. Min. Min. Min. Min. Min. Min. Min. Min. Min. Min. Min. Min. Min. Min. Min. Min. Min. Min. Typ. Typ. Min. Min. Min. Min. Min. -70 70 0 15 45 0 35 0 0 10 20 20 0 0 0 0 0 0 35 35 25 25 8 1 50 500 4 100 4 -90 90 0 15 45 0 45 0 0 10 20 20 0 0 0 0 0 0 45 45 25 25 8 1 50 500 4 100 4 -12 120 0 15 50 0 50 0 0 10 25 25 0 0 0 0 0 0 50 50 30 30 8 1 50 500 4 100 4 ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns s sec s ns s s s MBM29DL800TA/BA Unit
CE High During Toggle Bit Polling OE High During Toggle Bit Polling Read Recover Time Before Write Read Recover Time Before Write CE Setup Time WE Setup Time CE Hold Time WE Hold Time Write Pulse Width CE Pulse Width Write Pulse Width High CE Pulse Width High Byte Programming Operation Sector Erase Operation (Note 1) VCC Setup Time Rise Time to VID (Note 2) Voltage Transition Time (Note 2) Write Pulse Width (Note 2) OE Setup Time to WE Active (Note 2)
(Continued)
32
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
(Continued)
Parameter Symbols Description JEDEC -- -- -- -- -- -- -- -- Standard tCSP tRB tRP tRH tFLQZ tFHQV tBUSY tEOE CE Setup Time to WE Active (Note 2) Recover Time From RY/BY RESET Pulse Width RESET Hold Time Before Read BYTE Switching Low to Output High-Z BYTE Switching High to Output Active Program/Erase Valid to RY/BY Delay
Delay Time from Embedded Output Enable
MBM29DL800TA/BA Unit -70 Min. Min. Min. Min. Max. Min. Max. Max. 4 0 500 200 30 30 90 30 -90 4 0 500 200 35 35 90 35 -12 4 0 500 200 50 50 90 50 s ns ns ns ns ns ns ns
Notes: 1. This does not include the preprogramming time. 2. This timing is for Sector Protection operation.
33
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
s SWITCHING WAVEFORMS
* Key to Switching Waveforms
WAVEFORM
INPUTS Must Be Steady May Change from H to L May Change from L to H "H" or "L" Any Change Permitted Does Not Apply
OUTPUTS Will Be Steady Will Be Changing from H to L Will Be Changing from L to H Changing State Unknown Center Line is HighImpedance "Off" State
t RC
Addresses
Addresses Stable
t ACC
CE
t OE t DF
OE
t OEH
WE
t CE
Outputs
High-Z
Output Valid
High-Z
Figure 5.1
AC Waveforms for Read Operations
34
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
t RC
Addresses
t ACC
Addresses Stable
CE
t RH
t
RP
t
RH
t
CE
RESET
t OH
Outputs
High-Z
Output Valid
Figure 5.2
AC Waveforms for Hardware Reset/Read Operations
35
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
3rd Bus Cycle Addresses
555H t WC PA t AS t AH
Data Polling
PA t RC
CE
t CS t CH t CE
OE
t GHWL t WP t WPH t WHWH1 t OE
WE
t DS t DH t OH
Data
A0H
PD
DQ 7
D OUT
D OUT
Notes: 1. 2. 3. 4. 5. 6.
PA is address of the memory location to be programmed. PD is data to be programmed at byte address. DQ7 is the output of the complement of the data written to the device. DOUT is the output of the data written to the device. Figure indicates last two bus cycles out of four bus cycle sequence. These waveforms are for the x16 mode. (The addresses differ from x8 mode.)
Figure 6
Alternate WE Controlled Program Operations
36
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
3rd Bus Cycle
Data Polling PA t AS t AH PA
Addresses
555H t WC
WE
t WS t WH
OE
t GHEL t CP t CPH t WHWH1
CE
t DS t DH
Data
A0H
PD
DQ 7
D OUT
Notes: 1. 2. 3. 4. 5. 6.
PA is address of the memory location to be programmed. PD is data to be programmed at byte address. DQ7 is the output of the complement of the data written to the device. DOUT is the output of the data written to the device. Figure indicates last two bus cycles out of four bus cycle sequence. These waveforms are for the x16 mode. (The addresses differ from x8 mode.)
Figure 7
Alternate CE Controlled Program Operations
37
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
Addresses
555H t WC
2AAH t AS t AH
555H
555H
2AAH
SA
CE
t CS t CH
OE
t GHWL t WP t WPH
WE
t DS AAH
t DH 55H 80H AAH 55H 10H/ 30H
Data
t VCS
V CC
Notes: 1. SA is the sector address for Sector Erase. Addresses = 555H (Word), AAAH (Byte) for Chip Erase. 2. These waveforms are for the x16 mode. (The addresses differ from x8 mode.)
Figure 8
AC Waveforms Chip/Sector Erase Operations
38
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
CE
t CH
t OE
t DF
OE
t OEH
WE
t CE
* DQ7
Data DQ7 DQ7 = Valid Data High-Z
t WHWH1 or 2
DQ0 to DQ6
Data t BUSY
DQ0 to DQ6 = Output Flag t EOE
DQ0 to DQ6 Valid Data
High-Z
RY/BY
* : DQ7 = Valid Data (The device has completed the Embedded operation). Figure 9 AC Waveforms for Data Polling during Embedded Algorithm Operations
39
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
Address
tAHT tASO tAHT tAS
CE
tCEPH
WE
tOEH
tOEPH tOEH
OE
tDH tOE tCE *
DQ 6/DQ2
Data
tBUSY
Toggle Data
Toggle Data
Toggle Data
Stop
Toggling
Output Valid
RY/BY
* : DQ6 stops toggling (The device has completed the Embedded operation). Figure 10 AC Waveforms for Toggle Bit I during Embedded Algorithm Operations
40
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
CE
The rising edge of the last write pulse
WE
Entire programming or erase operations
RY/BY
t BUSY
Figure 11
RY/BY Timing Diagram during Program/Erase Operations
WE
RESET
tRP t RB
RY/BY
tREADY
Figure 12
RESET/RY/BY Timing Diagram
41
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
CE
BYTE
Data Output (DQ0 to DQ7) tELFH tFHQV A-1 DQ15 Data Output (DQ0 to DQ14)
DQ0 to DQ14
DQ15/A-1
Figure 13
Timing Diagram for Word Mode Configuration
CE
BYTE
tELFL
DQ0 to DQ14
Data Output (DQ0 to DQ14)
Data Output (DQ0 to DQ7)
DQ15/A-1
DQ15 tFLQZ
A-1
Figure 14
Timing Diagram for Byte Mode Configuration
The falling edge of the last write signal
CE or WE
BYTE
tSET (tAS)
Input Valid
tHOLD (tAH)
Figure 15 42
BYTE Timing Diagram for Write Operations
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
A18, A17, A16 A15, A14 A13, A12 A0
SAX
SAY
A1
A6
12 V 3V A9
t VLHT
12 V 3V OE
t VLHT t WPP t VLHT t VLHT
WE
t OESP
CE
t CSP
Data
t VCS t OE
01H
VCC
SAX : Sector Address for initial sector SAY : Sector Address for next sector Note: A-1 is VIL on byte mode. Figure 16 AC Waveforms for Sector Protection
43
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
VCC tVCS VID 3V RESET CE
tVIDR tVLHT
3V
WE
tVLHT RY/BY
Program or Erase Command Sequence
tVLHT
Unprotection period
Figure 17
Temporary Sector Unprotection Timing Diagram
Read
tRC
Command
tWC
Read
tRC
Command
tWC
Read
tRC
Read
tRC
Address
BA1
tAS
BA2 (555H)
tAH tACC
BA1
BA2 (PA)
BA1
tAS tAHT
BA2 (PA)
tCE
CE
tOE tCEPH
OE
tGHWL tWP tOEH tDF
WE
tDS tDH tDF
DQ
is read from the erase-suspended Valid sector. Note: DQ2 Valid Valid Valid
Output Intput (A0H) Output Intput (PD)
Valid Output
Status
Note: This is example of Read for Bank 1 and Embedded Algorithm (program) for Bank 2. BA1: Address of Bank 1. BA2: Address of Bank 2. Figure 18 44 Back-to-back Read/Write Timing Diagram
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
Enter Embedded Erasing WE
Erase Suspend Erase
Enter Erase Suspend Program Erase Suspend Program
Erase Resume Erase Suspend Read Erase Erase Complete
Erase Suspend Read
DQ6
DQ2 Toggle DQ2 and DQ6 with OE or CE
Note: DQ2 is read from the erase-suspended sector.
Figure 19
DQ2 vs. DQ6
45
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
VCC
tVCS
RESET tVIDR Add
tVLHT
SPAX
SPAX
SPAY
A0
A1
A6
CE
OE tWP TIME-OUT
WE
Data
60H
60H
40H tOE
01H
60H
SPAX : Sector Address to be protected SPAY : Next Sector Address to be protected TIME-OUT : Time-Out window = 150 s (min) Figure 20 Extended Sector Protection Timing Diagram
46
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
EMBEDDED ALGORITHMS
Start
Write Program Command Sequence (See below)
Data Polling Device
Increment Address
No
Last Address ? Yes
Programming Completed
Program Command Sequence* (Address/Command):
555H/AAH
2AAH/55H
555H/A0H
Program Address/Program Data
* : The sequence is applied for x 16 mode. The addresses differ from x 8 mode.
Figure 21
Embedded ProgramTM Algorithm
47
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
EMBEDDED ALGORITHMS
Start
Write Erase Command Sequece (See below) Data Polling or Toggle Bit Successfully Completed
Erasure Completed Individual Sector/Multiple Sector* Erase Command Sequence (Address/Command): 555H/AAH
Chip Erase Command Sequence* (Address/Command): 555H/AAH
2AAH/55H
2AAH/55H
555H/80H
555H/80H
555H/AAH
555H/AAH
2AAH/55H
2AAH/55H
555H/10H
Sector Address/30H
Sector Address/30H
Additional sector erase commands are optional.
Sector Address/30H
* : The sequence is applied for x 16 mode. The addresses differ from x 8 mode.
Figure 22
Embedded EraseTM Algorithm
48
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
Start
Read (DQ 0 to DQ 7) Addr. = VA
DQ 7 = Data? No No DQ 5 = 1? Yes Read (DQ 0 to DQ 7) Addr. = VA
Yes
VA = Byte address for programming = Any of the sector addresses within the sector being erased during sector erase or multiple sector erases operation = Any of the sector addresses within the sector not being protected during chip erase
DQ 7 = Data? No Fail
Yes
Pass
Note: DQ7 is rechecked even if DQ5 = "1" because DQ7 may change simultaneously with DQ5.
Figure 23
Data Polling Algorithm
49
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
Start
Read (DQ 0 to DQ 7) Addr. = VA
VA = Bank address being executed Embedded Algorithm.
No
DQ 6 = Toggle ? Yes No DQ 5 = 1? Yes Read (DQ 0 to DQ 7) Addr. = VA
DQ 6 = Toggle ? Yes Fail
No
Pass
Note: DQ6 is rechecked even if DQ5 = "1" because DQ6 may stop toggling at the same time as DQ5 changing to "1" .
Figure 24
Toggle Bit Algorithm
50
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
Start
Setup Sector Addr. (A18, A17, A16, A15, A14, A13, A12)
PLSCNT = 1
OE = V ID, A 9 = V ID, A 6 = CE = V IL, RESET = V IH A 0 = V IL, A 1 = V IH Activate WE Pulse
Increment PLSCNT
Time out 100 s
WE = V IH, CE = OE = V IL (A 9 should remain V ID)
Read from Sector (Addr. = SA, A 0 = V IL, A 1 = V IH, A 6 = V IL)* No No PLSCNT = 25? Yes Remove V ID from A 9 Write Reset Command Data = 01H? Yes Yes Protect Another Sector? No Device Failed Remove V ID from A 9 Write Reset Command
Sector Protection Completed
* : A-1 is V IL on byte mode.
Figure 25
Sector Protection Algorithm
51
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
Start
RESET = VID (Note 1)
Perform Erase or Program Operations
RESET = VIH
Temporary Sector Unprotection Completed (Note 2)
Notes: 1. All protected sectors are unprotected. 2. All previously protected sectors are protected once again.
Figure 26
Temporary Sector Unprotection Algorithm
52
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
FAST MODE ALGORITHM
Start
RESET = VID
Wait to 4 s
Device is Operating in Temporary Sector Unprotection Mode
No
Extended Sector Protection Entry? Yes To Setup Sector Protection Write XXXH/60H
PLSCNT = 1
To Sector Protection Write SPA/60H (A0 = VIL, A1 = VIH, A6 = VIL)
Increment PLSCNT
Time Out 150 s
To Verify Sector Protection Write SPA/40H (A0 = VIL, A1 = VIH, A6 = VIL)
Setup Next Sector Address
Read from Sector Address (A0 = VIL, A1 = VIH, A6 = VIL) No No PLSCNT = 25? Yes Remove VID from RESET Write Reset Command Data = 01H? Yes Protection Other Sector ? No Remove VID from RESET Write Reset Command Yes
Device Failed
Sector Protection Completed
Figure 27
Extended Sector Protection Algorithm
53
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
FAST MODE ALGORITHM
Start
555H/AAH
2AAH/55H
Set Fast Mode
555H/20H
XXXH/A0H
Program Address/Program Data
Data Polling Device
Verify Byte? Yes No
No
In Fast Program
Increment Address
Last Address ? Yes Programming Completed
(BA) XXXH/90H Reset Fast Mode XXXH/F0H
* : The sequence is applied for x 16 mode. The addresses differ from x 8 mode. Figure 28 Embedded ProgramTM Algorithm for Fast Mode
54
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
s ERASE AND PROGRAMMING PERFORMANCE
Limits Parameter Min. Sector Erase Time Word Programming Time Byte Programming Time Chip Programming Time Program/Erase Cycle -- -- -- -- 100,000 Typ. 1 16 8 8.4 -- Max. 10 360 300 25 -- sec s s sec cycles Excludes programming time prior to erasure Excludes system-level overhead Excludes system-level overhead -- Unit Comments
s TSOP(I) PIN CAPACITANCE
Parameter Symbol CIN COUT CIN2 Parameter Description Input Capacitance Output Capacitance Control Pin Capacitance Test Setup VIN = 0 VOUT = 0 VIN = 0 Typ. 6 8.5 8 Max. 7.5 12 10 Unit pF pF pF
Note: Test conditions TA = 25C, f = 1.0 MHz
s FBGA PIN CAPACITANCE
Parameter Symbol CIN COUT CIN2 Parameter Description Input Capacitance Output Capacitance Control Pin Capacitance Test Setup VIN = 0 VOUT = 0 VIN = 0 Typ. 6 8.5 8 Max. 7.5 12 10 Unit pF pF pF
Note: Test conditions TA = 25C, f = 1.0 MHz
55
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
s PACKAGE DIMENSIONS
48-pin plastic TSOP(I) (FPT-48P-M19)
LEAD No.
1 48
* Resin Protrusion. (Each Side: 0.15 (.006)Max)
INDEX
Details of "A" part 0.15(.006) MAX
"A" 0.15(.006)
0.35(.014) MAX 0.25(.010)
24
25
20.000.20 (.787.008) * 18.400.20 (.724.008)
* 12.000.20
(.472.008) 11.50REF (.460) 1.10 -0.05
+0.10 +.004
.043 -.002 (Mounting height)
(Mounting height)
0.10(.004)
0.50(.0197) TYP 0.150.05 (.006.002) 0.200.10 (.008.004)
0.05(0.02)MIN (STAND OFF) 0.10(.004)
M
19.000.20 (.748.008)
0.500.10 (.020.004)
C
1996 FUJITSU LIMITED F48029S-2C-2
Dimensions in mm (inches)
48-pin plastic TSOP(I) (FPT-48P-M20)
EAD No.
1 48
* Resin Protrusion. (Each Side: 0.15 (.006)Max)
INDEX
Details of "A" part 0.15(.006) MAX
"A" 0.15(.006)
0.35(.014) MAX 0.25(.010)
24
25
19.000.20 (.748.008)
0.500.10 (.020.004) 0.150.10 (.006.002) 0.200.10 (.008.004) 0.10(.004)
M
0.10(.004)
0.50(.0197) TYP
0.05(0.02)MIN (STAND OFF)
1.10 -0.05
+0.10 +.004
* 18.400.20
(.724.008) 20.000.20 (.787.008)
11.50(.460)REF
.043 -.002 (Mounting height) (Mounting height)
* 12.000.20(.472.008)
C
1996 FUJITSU LIMITED F48030S-2C-2
Dimensions in mm (inches)
(Continued)
56
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
(Continued)
48-pin plastic FBGA (BGA-48P-M02)
9.000.20(.354.008)
Note: The actual shape of corners may differ from the dimension.
1.20(.047)MAX (Mounting height) 0.350.10(.014.004) (Stand off)
5.60(.221)
(Mounting height)
0.80(.031)NOM
6 0.80(.031) NOM 4.00(.157) 5 4 3 2 1 H G F E D C B A
INDEX
6.000.20 (.236.008)
O0.400.10 (.016.004)
O0.08(.003)
M
0.10(.004)
C
1997 FUJITSU LIMITED B48002S-1C-2
Dimensions in mm (inches)
(Continued)
57
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
(Continued)
48-pin plastic FBGA (BGA-48P-M12)
9.000.20(.354.008)
+0.15
Note: The actual shape of corners may differ from the dimension.
1.05 -0.10 .041 -.004 (Mounting height) 0.380.10(.015.004) (Stand off)
+.006
5.60(.221) 0.80(.031)TYP
6 5 INDEX 6.000.20 (.236.008) 4 4.00(.157) 3 2 1
H C0.25(.010)
G
F
E
D
C
B
A
M
48-O0.450.10 (48-.018.004)
O0.08(.003)
0.10(.004)
C
1998 FUJITSU LIMITED B480012S-2C-2
Dimensions in mm (inches)
58
To Top / Lineup / Index
MBM29DL800TA-70/-90/-12/MBM29DL800BA-70/-90/-12
FUJITSU LIMITED
For further information please contact:
Japan FUJITSU LIMITED Corporate Global Business Support Division Electronic Devices KAWASAKI PLANT, 4-1-1, Kamikodanaka Nakahara-ku, Kawasaki-shi Kanagawa 211-8588, Japan Tel: 81(44) 754-3763 Fax: 81(44) 754-3329
All Rights Reserved. The contents of this document are subject to change without notice. Customers are advised to consult with FUJITSU sales representatives before ordering. The information and circuit diagrams in this document are presented as examples of semiconductor device applications, and are not intended to be incorporated in devices for actual use. Also, FUJITSU is unable to assume responsibility for infringement of any patent rights or other rights of third parties arising from the use of this information or circuit diagrams. FUJITSU semiconductor devices are intended for use in standard applications (computers, office automation and other office equipment, industrial, communications, and measurement equipment, personal or household devices, etc.). CAUTION: Customers considering the use of our products in special applications where failure or abnormal operation may directly affect human lives or cause physical injury or property damage, or where extremely high levels of reliability are demanded (such as aerospace systems, atomic energy controls, sea floor repeaters, vehicle operating controls, medical devices for life support, etc.) are requested to consult with FUJITSU sales representatives before such use. The company will not be responsible for damages arising from such use without prior approval. Any semiconductor devices have an inhereut chance of failure. You must protect against injury, damage or loss from such failures by incorporating safety design measures into your facility and equipment such as redundancy, fire protection, and prevention of over-current levels and other abnormal operating conditions. If any products described in this document represent goods or technologies subject to certain restrictions on export under the Foreign Exchange and Foreign Trade Law of Japan, the prior authorization by Japanese government will be required for export of those products from Japan.
http://www.fujitsu.co.jp/
North and South America FUJITSU MICROELECTRONICS, INC. Semiconductor Division 3545 North First Street San Jose, CA 95134-1804, USA Tel: (408) 922-9000 Fax: (408) 922-9179 Customer Response Center Mon. - Fri.: 7 am - 5 pm (PST) Tel: (800) 866-8608 Fax: (408) 922-9179
http://www.fujitsumicro.com/
Europe FUJITSU MIKROELEKTRONIK GmbH Am Siebenstein 6-10 D-63303 Dreieich-Buchschlag Germany Tel: (06103) 690-0 Fax: (06103) 690-122
http://www.fujitsu-ede.com/
Asia Pacific FUJITSU MICROELECTRONICS ASIA PTE LTD #05-08, 151 Lorong Chuan New Tech Park Singapore 556741 Tel: (65) 281-0770 Fax: (65) 281-0220
http://www.fmap.com.sg/
F9904 (c) FUJITSU LIMITED Printed in Japan
59


▲Up To Search▲   

 
Price & Availability of MBM29DL800TA-12

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X