Data Sheet 27621.30A 3161 HALL-EFFECT SWITCH FOR 2-WIRE APPLICATIONS This Hall-effect switch is a monolithic integrated circuit designed to operate continuously over extended temperatures to +85C. The unipolar switching characteristic makes this device ideal for use with a simple bar or rod magnet. The A3161ELT and A3161EUA are identical except for package. Each device includes a voltage regulator for operation with supply voltages of 3.5 to 25 volts, reverse battery protection diode, quadratic Hall-voltage generator, temperature compensation circuitry, small-signal amplifier, Schmitt trigger, and a constant-current open-collector output. Noise radiation is limited by control of the output current slew rate. Two package styles provide a magnetically optimized package for most applications. Suffix `LT' is a miniature SOT-89/TO-243AA transistor package for surface-mount applications; suffix `UA' is a threelead ultra-mini SIP for through-hole mounting. V X CC 1 2 3 GROUND Dwg. PH-003-3 OUTPUT SUPPLY FEATURES and BENEFITS s s s s s s s s s Pinning is shown viewed from branded side. ABSOLUTE MAXIMUM RATINGS at TA = +25C Supply Voltage, VCC Continuous ................................. 28 V Surge (tw 100 ms) .................... 40 V Reverse Battery Voltage, VRCC Continuous ................................ -25 V Surge (tw 100 ms) ................... -40 V Magnetic Flux Density, B ....... Unlimited Output OFF Voltage, VOUT .............. 28 V Operating Temperature Range, TA ............................. -40C to +85C Storage Temperature Range, TS ........................... -65C to +170C Internal Current Regulator for 2-Wire Operation Output Slew Rate Controlled 3.5 V to 25 V Operation ... Needs Only An Unregulated Supply Reverse Battery Protection Excellent Temp. Stability Activate with Small, Commercially Available Permanent Magnets Small Size Solid-State Reliability ... No Moving Parts Resistant to Physical Stress Always order by complete part number, e.g., A3161ELT . 3161 HALL-EFFECT SWITCH FOR 2-WIRE APPLICATIONS ELECTRICAL CHARACTERISTICS over operating voltage and temperature ranges. Limits Characteristic Supply Voltage Load Current (2-wire application) Symbol VCC IOUT + ICC Test Conditions Operating 3.5 V VOUT < 12 V, B < BRP VOUT 12 V, B < BRP B > BOP Output Current IOUT IOFF Output Saturation Voltage Output Slew Rate Output Settling Time VOUT di/dt tsd B < BRP VOUT = 24 V, B > BOP IOUT = 5 mA, B < BRP CL = 20 pF CL = 20 pF Min. 3.5 12 12 -- -- -- - -- -- Typ. -- 15 15 3.5 12 <1.0 0.9 7.0 -- Max. 25 17 19 5.0 -- 10 1.5 20 20 Units V mA mA mA mA A V mA/s s MAGNETIC CHARACTERISTICS over operating supply voltage range. Limits At TA = +25C Characteristic Operate Point (output turns OFF) Release Point (output turns ON) Hysteresis (BOP - BRP) Symbol BOP BRP Bhys Min. - 30 5.0 Typ. 130 110 20 Max. 160 - - Over Oper. Temp. Range Min. - 30 5.0 Typ. 130 110 20 Max. 160 - 80 Units G G G NOTE:Typical values are at TA = +25C and VCC = 12 V. FUNCTIONAL BLOCK DIAGRAM 1 VCC 3 OUTPUT REG. X 2 GROUND Dwg. FH-017 115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000 Copyright (c) 1998, 1999, Allegro MicroSystems, Inc. 3161 HALL-EFFECT SWITCH FOR 2-WIRE APPLICATIONS TYPICAL OPERATING CHARACTERISTICS SWITCH POINTS 200 TOTAL SUPPLY CURRENT 20 + I CC ) in mA VCC = 25 V 15 VCC = 3.5 V 150 B < BRP SWITCH POINT in GAUSS OPERATE POINT 100 RELEASE POINT TOTAL SUPPLY CURRENT (I OUT 10 50 5.0 VCC = 25 V VCC = 3.5 V 0 -50 B > BOP OVER OPER. VOLT. RANGE 0 -50 -25 0 25 50 75 100 125 150 -25 0 25 50 75 100 125 150 AMBIENT TEMPERATURE in C Dwg. GH-044-1 AMBIENT TEMPERATURE in C Dwg. GH-028-4 OUTPUT SATURATION VOLTAGE 1200 SAFE OPERATING AREA 30 MAXIMUM CONTINUOUS SUPPLY VOLTAGE in VOLTS 1000 25 SATURATION VOLTAGE in mV 800 20 PACKAGE SUFFIX CODE -UA 15 PACKAGE SUFFIX CODE -LT 10 600 400 200 IOUT = 5 mA VCC = 10 V 5 0 -50 0 -25 0 25 50 75 100 125 150 20 40 60 80 100 120 140 160 180 AMBIENT TEMPERATURE in C Dwg. GH-029-3 AMBIENT TEMPERATURE in C Dwg. GH-068 3161 HALL-EFFECT SWITCH FOR 2-WIRE APPLICATIONS SENSOR LOCATIONS Suffix "LT" ACTIVE AREA DEPTH 0.030" 0.76 mm NOM 0.085" 2.16 mm 0.045" 1.14 mm OPERATION The output of these devices (pin 3) switches OFF when the magnetic field at the Hall sensor exceeds the operate point threshold (BOP). When the magnetic field is reduced to below the release point threshold (BRP), the device output switches ON. The difference in the magnetic operate and release points is called the hysteresis (Bhys) of the device. This built-in hysteresis allows clean switching of the output even in the presence of external mechanical vibration and electrical noise. 15 A 1 2 3 12 BOP Dwg. MH-008-7 OUTPUT CURRENT in mA 9.0 Suffix "UA" ACTIVE AREA DEPTH 0.018" 0.46 mm NOM 0.078" 1.98 mm 6.0 TA = +25C 3.0 BRP A BRANDED SURFACE 1 2 3 0.054" 1.36 mm 0 0 25 50 75 100 125 150 175 200 MAGNETIC FLUX DENSITY in GAUSS Dwg. GH-007-1 APPLICATIONS INFORMATION Dwg. MH-011-8 These devices are normally operated in a 2-wire mode, where the supply terminal and the output terminal are tied together. An external comparator detects the change in total supply current by the addition (output ON, B > BOP) or subtraction (output OFF, B < BRP) of IOUT. Hall effect applications information is available in the "Hall-Effect IC Applications Guide", which can be found in the latest issue of the Allegro MicroSystems Electronic Data Book, AMS-702 or Application Note 27701, or at www.allegromicro.com. TYPICAL 2-WIRE APPLICATION SUPPLY Icc + IoUT 3 0.1 F 2 V CC 100 Dwg. EH-011 X 1 115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000 3161 HALL-EFFECT SWITCH FOR 2-WIRE APPLICATIONS PACKAGE DESIGNATOR `LT' Dimensions in Inches (for reference only) 0.173 0.181 0.064 0.072 0.090 0.102 0.055 0.063 0.014 0.017 0.155 0.167 1 2 3 0.084 0.090 0.035 0.047 0.059 BSC 0.014 0.019 0.017 0.022 0.118 BSC Dwg. MA-009-3 in Dimensions in Millimeters (controlling dimensions) 4.40 4.60 1.62 1.83 2.29 2.60 1.40 1.60 0.35 0.44 3.94 4.25 1 2 3 2.13 2.29 0.89 1.20 1.50 BSC 0.36 0.48 0.44 0.56 3.00 BSC Dwg. MA-009-3 mm 3161 HALL-EFFECT SWITCH FOR 2-WIRE APPLICATIONS PACKAGE DESIGNATOR `UA' Dimensions in Inches (controlling dimensions) 0.164 0.159 Dimensions in Millimeters (for reference only) 4.17 4.04 45 0.062 0.058 45 1.57 1.47 0.122 0.117 45 0.031 3.10 2.97 45 0.79 0.085 MAX 1 2 3 2.16 MAX 1 2 3 0.640 0.600 0.015 16.26 15.24 0.38 SEE NOTE 0.016 SEE NOTE 0.41 0.050 BSC Dwg. MH-014D in 1.27 BSC Dwg. MH-014D mm NOTES: 1. Tolerances on package height and width represent allowable mold offsets. Dimensions given are measured at the widest point (parting line). 2. Exact body and lead configuration at vendor's option within limits shown. 3. Height does not include mold gate flash. 115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000 3161 HALL-EFFECT SWITCH FOR 2-WIRE APPLICATIONS Allegro MicroSystems, Inc. reserves the right to make, from time to time, such departures from the detail specifications as may be required to permit improvements in the design of its products. The information included herein is believed to be accurate and reliable. However, Allegro MicroSystems, Inc. assumes no responsibility for its use; nor for any infringements of patents or other rights of third parties which may result from its use. 3161 HALL-EFFECT SWITCH FOR 2-WIRE APPLICATIONS HALL-EFFECT SENSORS SELECTION GUIDE Partial Part Number 3240 3210 3361 3362 3161 3141 3235 5140 3142 3143 3144 3122 3123 3121 3150 Avail. Oper. Characteristics at TA = +25C Temp. BOP(max) BRP(min) Bhys(typ) Features HALL-EFFECT UNIPOLAR SWITCHES in order of BOP and Bhys E/L E E E E E/L S E E/L E/L E/L E/L E/L E/L J +50 70 +120 +120 +160 +160 +175 -25 +200 +230 +340 +350 +400 +440 +450 +40 to +850 +5.0 5.0 +50 +50 +30 +10 +25 -175 +50 +75 +165 +50 +140 +180 +125 - 10 7.7 5.0* 5.0* 20 55 15* 15* 55 55 55 55 105 105 105 20 chopper stabilized micropower, chopper stabilized 2-wire, chopper stabilized 2-wire, chopper stabilized 2-wire output 1 output 2 300 mA output Notes 1 2 2 1, 3 programmable, chopper stabilized HALL-EFFECT LATCHES & BIPOLAR SWITCHES in order of BOP and Bhys 1 3260 E/L +30 -30 20 bipolar, chopper stabilized 3280 E/L +40 -40 45 chopper stabilized 3134 E/L +50 -50 27 bipolar switch 3133 K/L/S +75 -75 52 bipolar switch 3281 E/L +90 -90 100 chopper stabilized 3132 K/L/S +95 -95 52 bipolar switch 3187 E/L +150 -150 100* 3177 S +150 -150 200 3625 S +150 -150 200 900 mA outputs 1, 3, 5 3626 S +150 -150 200 400 mA outputs 1, 3, 5 3195 E/L +160 -160 220 1, 4 3197 L +160 -160 230 1 3175 S +170 -170 200 3188 E/L +180 -180 200* 3283 E/L +180 -180 300 chopper stabilized 3189 E/L +230 -230 100* 3275 S +250 -250 100* 5 3185 E/L +270 -270 340* Operating Temperature Ranges: S = -20C to +85C, E = -40C to +85C, J = -40C to +115C, K = -40C to +125C, L = -40C to +150C Notes 1. Protected. 2.Output 1 switches on south pole, output 2 switches on north pole for 2-phase, bifilar-wound, unipolar-driven brushless dc motor control. 3. Power driver output. 4.Active pull down. 5.Complementary outputs for 2-phase bifilar-wound, unipolar-driven brushless dc motor control. * Minimum. Latches will not switch on removal of magnetic field; bipolar switches may switch on removal of field but require field reversal for reliable operation over operating temperature range. 115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000 |
Price & Availability of 3161 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |