![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
19-2735; Rev 1; 3/04 K ATION EVALU BLE AVAILA IT ORing MOSFET Controllers with Fastest Fault Isolation for Redundant Power Supplies General Description Features Simple, Integrated, and Inexpensive ORing MOSFET Controller ORing MOSFET Drive for 12V (MAX8535/MAX8585) and 3.3V or 5V (MAX8536) Bus Eliminates ORing Diode Power Dissipation and Reverse Leakage Current Provides N + 1 Redundant Supply Capability for Highly Reliable Systems Isolates Failed Supply from Output Bus in <1s Reverse-Current Flow Detection Programmable Soft-Start Logic-Enable Input Adjustable Overvoltage and Undervoltage Trip Points Fault-Indicator Output Space-Saving 8-Pin MAX Package MAX8535/MAX8536/MAX8585 Critical loads often employ parallel-connected power supplies with redundancy in order to enhance system reliability. The MAX8535/MAX8536/MAX8585 are highly integrated but inexpensive MOSFET controllers that provide isolation and redundant power capability in high-reliability systems. The MAX8535/MAX8585 are used in 12V systems, and have an internal charge pump to drive the gates of the n-channel pass elements to VCC + 10V. The MAX8536 is used in 3.3V and 5V systems, with a chargepump output of VCC + 5V. During startup, the MAX8535/MAX8536/MAX8585 monitor the voltage drop across external MOSFETs. Once V CC approaches or exceeds the bus voltage, the MOSFETs are turned on. The MAX8535/MAX8536/ MAX8585 feature a dual-purpose TIMER input. A single external resistor from TIMER to ground sets the turn-on speed of the external MOSFETs. Optionally, the TIMER input can be used as a logic-enable pin. Once the device is turned on, the MAX8535/MAX8536/MAX8585 monitor the load, protecting against overvoltage, undervoltage, and reverse-current conditions. Overvoltage and undervoltage fault thresholds are adjustable and can be disabled. The current-limit trip points are set by the external MOSFETs' R DS(ON) , reducing component count. An open-drain logic-low fault output indicates if an overvoltage, undervoltage, or reverse-current fault occurs. All devices come in a space-saving 8-pin MAX (R) package and are specified over the extended -40C to +85C temperature range. MAX is a registered trademark of Maxim Integrated Products, Inc. Ordering Information PART MAX8535EUA MAX8535AEUA MAX8536EUA MAX8585EUA TEMP RANGE -40C to +85C -40C to +85C -40C to +85C -40C to +85C PIN-PACKAGE 8 MAX 8 MAX 8 MAX 8 MAX Typical Operating Circuit OUTPUT: 3.3V/5V (MAX8536), 12V (MAX8535) +VO -VO Applications Silver Box Supplies for Servers On-Board Redundant Power Supplies in Blade Servers Network/Telecom Power Supplies Rectifiers Redundant Power Supplies in High-Availability Systems SILVER BOX OR RECTIFIERS VCC GATE CS OUT+ FAULT TIMER MAX8535 MAX8536 MAX8585 GND UVP OVP N.C. Pin Configuration, Functional Diagrams, and Typical Application Circuits appear at end of data sheet. OUT- ________________________________________________________________ Maxim Integrated Products REDUNDANT OUTPUT BUS 1 For pricing, delivery, and ordering information, please contact Maxim/Dallas Direct! at 1-888-629-4642, or visit Maxim's website at www.maxim-ic.com. ORing MOSFET Controllers with Fastest Fault Isolation for Redundant Power Supplies MAX8535/MAX8536/MAX8585 ABSOLUTE MAXIMUM RATINGS GATE to GND (MAX8535/MAX8535A/MAX8585)...-0.3V to +28V VCC to GND (MAX8535/MAX8535A/MAX8585) .....-0.3V to +18V CS, FAULT to GND (MAX8535/MAX8535A/MAX8585) ......................-0.3V to +15V GATE to GND (MAX8536) ............................ -0.3V to (VCC + 6V) VCC, CS, FAULT to GND (MAX8536) .......................-0.3V to +6V OVP, UVP, TIMER to GND........................................-0.3V to +6V Continuous Power Dissipation (TA = +70C) 8-Pin MAX (derate 4.5mW/C above +70C) .............362mW Operating Temperature Range ...........................-40C to +85C Storage Temperature Range .............................-65C to +150C Junction Temperature ....................................................+150C Lead Temperature (soldering, 10s) .................................+300C Stresses beyond those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. ELECTRICAL CHARACTERISTICS (VCC = 12V (MAX8535/MAX8535A/MAX8585), VCC = 5V (MAX8536), VCS = VCC - 0.1V, RTIMER = 25k, UVP = 2V, OVP = 1V, CGATE = 0.01F, TA = 0C to +85C, unless otherwise noted.) PARAMETER VCC SUPPLY VCC Supply Current TIMER = 2.5V VCC = 14V (MAX8535/ MAX8535A/MAX8585) VCC = 6V (MAX8536) VCC Shutdown Current TIMER = 0V VCC = 14V (MAX8535/ MAX8535A/MAX8585) VCC = 6V (MAX8536) MAX8535/MAX8535A/ MAX8585, charge pump on VCC Input Voltage TIMER = 2.5V MAX8536, charge pump on MAX8535/MAX8535A/ MAX8585, charge pump off CS Input Current CS Isolation VCC Undervoltage Lockout VCCOK TIMER = 2.5V CS = 14V (MAX8535/ MAX8535A/MAX8585) CS = 5.5V (MAX8536) CS = max operating voltage, VCC = 0V, I(VCC) MAX8535/MAX8535A/MAX8585, rising threshold MAX8536, rising threshold VCC Overvoltage Internal Threshold CHARGE-PUMP VOLTAGE Measured from VGATE to VCC, VCC = 3.3V (MAX8536) Gate Voltage VGATE VCC = 5V (MAX8536) VCC = 12V (MAX8535/MAX8535A/MAX8585) 5 5 9 5.5 5.5 11 6 6 12 V MAX8535/ MAX8535A/ MAX8585 Rising threshold Falling threshold 6 2.5 14 13.3 100 50 -0.05 6.5 2.7 14.5 13.9 -1 7 2.9 15 V 14.5 A V 8 3.0 2 2 4.5 3 4.5 3 14 5.5 17 V mA mA SYMBOL CONDITIONS MIN TYP MAX UNITS A 2 _______________________________________________________________________________________ ORing MOSFET Controllers with Fastest Fault Isolation for Redundant Power Supplies ELECTRICAL CHARACTERISTICS (continued) (VCC = 12V (MAX8535/MAX8535A/MAX8585), VCC = 5V (MAX8536), VCS = VCC - 0.1V, RTIMER = 25k, UVP = 2V, OVP = 1V, CGATE = 0.01F, TA = 0C to +85C, unless otherwise noted.) PARAMETER Charge-Pump Switching Frequency TIMER TIMER Voltage TIMER Maximum Source Current TIMER High-Input Current TIMER Maximum Frequency Select Voltage Input Range TIMER Logic High TIMER Logic Low FAULT Fault Output Low Voltage Fault Sink Current Fault Leakage Current GATE Gate On Threshold Measured from VCC to CS VGATE = VCC = 12V ITIMER = 0A (MAX8535/ MAX8535A/MAX8585) ITIMER = 50A (MAX8535/ MAX8535A/MAX8585) ITIMER = 0A (MAX8536) ITIMER = 50A (MAX8536) 0.3 35 15 17 8 0.4 50 25 25 12 200 100 200 200 300 0.7 0.55 0.5 65 36 33 16 300 300 400 ns A V IFAULT = 0.5mA FAULT = 0.8V FAULT = 18V (MAX8535 /MAX8535A/MAX8585) FAULT = 6V (MAX8536) 0.5 5 5 0.8 V mA A VIH VIL VTIMER = 1V VTIMER = 1.5V MAX8535/MAX8535A/MAX8585 MAX8536 Charge pump enabled Charge pump disabled 1.5 1.5 1.0 0.5 1.219 80 1.25 100 10 1.281 120 20 3.4 VCC - 0.6 V A A V V V SYMBOL RTIMER = 20k RTIMER = 125k RTIMER = open VTIMER = 1.5V CONDITIONS MIN TYP 187 450 500 550 kHz MAX UNITS MAX8535/MAX8536/MAX8585 Gate Drive Current VGATE = VCC = 5V Gate Shutdown Delay From fault sense to the start of gate voltage falling, or from TIMER to the start of gate voltage falling GATE = VCC + 5V (MAX8535/MAX8536) GATE = VCC + 5V (MAX8535A/MAX8585) Gate voltage fall from fault to VGATE = VCC, CGATE = 0.01F (200ns + CV/I = 700ns, typ) (MAX8535/MAX8536) MAX8535A/MAX8585 Gate Discharge Current mA Gate Fall Time s CURRENT SENSE Reverse-Current Threshold Measured from CS to VCC (MAX8535/MAX8535A/MAX8536) MAX8585 20 -3 30 0 40 +3 mV _______________________________________________________________________________________ 3 ORing MOSFET Controllers with Fastest Fault Isolation for Redundant Power Supplies MAX8535/MAX8536/MAX8585 ELECTRICAL CHARACTERISTICS (continued) (VCC = 12V (MAX8535/MAX8535A/MAX8585), VCC = 5V (MAX8536), VCS = VCC - 0.1V, RTIMER = 25k, UVP = 2V, OVP = 1V, CGATE = 0.01F, TA = 0C to +85C, unless otherwise noted.) PARAMETER Startup Reverse-Current Blank Time Forward-Current Threshold OVERVOLTAGE PROTECTION OVP Fault Threshold OVP Bias Current UNDERVOLTAGE PROTECTION UVP Fault Voltage UVP Bias Current VUVP UVP rising threshold UVP falling threshold 1.219 1.119 1.25 1.15 1.281 1.181 0.4 V A VOVP SYMBOL CONDITIONS TIMER = open (MAX8535/MAX8535A/ MAX8536) MAX8585 Measured from VCC to CS OVP rising OVP falling 5 1.219 MIN TYP 524 32 10 1.25 1.2 0.2 MAX UNITS ms 15 1.281 mV V A ELECTRICAL CHARACTERISTICS (VCC = 12V (MAX8535/MAX8535A/MAX8585), VCC = 5V (MAX8536), VCS = VCC - 0.1V, RTIMER = 25k, UVP = 2V, OVP = 1V, CGATE = 0.01F, TA = -40C to +85C, unless otherwise noted.) (Note 1) PARAMETER VCC SUPPLY VCC Supply Current VCC = 14V (MAX8535/ TIMER = 2.5V MAX8535A/MAX8585) VCC = 6V (MAX8536) VCC Shutdown Current TIMER = 0V VCC = 14V (MAX8535/ MAX8535A/MAX8585) VCC = 6V (MAX8536) MAX8535/MAX8535A/ MAX8585, charge pump on VCC Input Voltage TIMER = 2.5V MAX8536, charge pump on MAX8535/MAX8535A/ MAX8585, charge pump off CS Isolation VCC Undervoltage Lockout VCCOK CS = max operating voltage, VCC = 0V, I(VCC) (MAX8535/MAX8535A/MAX8585) rising threshold (MAX8536) rising threshold VCC Overvoltage Internal Threshold (MAX8535/ MAX8535A/ MAX8585) Rising threshold Falling threshold 6.0 2.5 14 13.3 8 3.0 4.5 3 4.5 3 14 5.5 17 -1 7.0 2.9 15 V 14.5 A V V mA mA SYMBOL CONDITIONS MIN TYP MAX UNITS 4 _______________________________________________________________________________________ ORing MOSFET Controllers with Fastest Fault Isolation for Redundant Power Supplies ELECTRICAL CHARACTERISTICS (continued) (VCC = 12V (MAX8535/MAX8535A/MAX8585), VCC = 5V (MAX8536), VCS = VCC - 0.1V, RTIMER = 25k, UVP = 2V, OVP = 1V, CGATE = 0.01F, TA = -40C to +85C, unless otherwise noted.) (Note 1) PARAMETER CHARGE-PUMP VOLTAGE Measured from VGATE to VCC, VCC = 3.3V (MAX8536) Gate Voltage VGATE VCC = 5V (MAX8536) VCC = 12V (MAX8535/MAX8535A/MAX8585) TIMER TIMER Voltage TIMER Maximum Source Current TIMER High-Input Current TIMER Maximum Frequency Select Voltage Input Range TIMER Logic High TIMER Logic Low FAULT Fault Output Low Voltage Fault Sink Current Fault Leakage Current GATE Gate On Threshold Measured from VCC to CS VGATE = VCC = 12V VGATE = VCC = 5V Gate Shutdown Delay ITIMER = 0A (MAX8535/ MAX8535A/MAX8585) ITIMER = 50A (MAX8535/ MAX8535A/MAX8585) ITIMER = 0A (MAX8536) ITIMER = 50A (MAX8536) 0.3 35 15 17 8 0.5 65 36 33 16 300 100 200 300 400 ns A V IFAULT = 0.5mA FAULT = 0.8V FAULT = 18V (MAX8535/ MAX8535A/MAX8585) FAULT = 6V (MAX8536) 0.5 5 5 0.8 V mA A VIH VIL VTIMER = 1.0V VTIMER = 1.5V MAX8535/MAX8535A/MAX8585 MAX8536 Charge pump enabled Charge pump disabled 1.5 1.5 1.1 0.5 1.200 80 1.281 120 20 3.4 VCC - 0.6 V A A V V V 5 5 9 6 6 12 V SYMBOL CONDITIONS MIN TYP MAX UNITS MAX8535/MAX8536/MAX8585 Gate-Drive Current From fault sense to the start of gate voltage falling, or from TIMER to the start of gate voltage falling GATE = VCC + 5V (MAX8535/MAX8536) MAX8535A/MAX8585 Measured from CS to VCC (MAX8535/MAX8535A/MAX8586) MAX8585 Measured from VCC to CS Gate Discharge Current CURRENT SENSE Reverse-Current Threshold Forward-Current Threshold mA 20 -5 5 40 +5 15 mV mV _______________________________________________________________________________________ 5 ORing MOSFET Controllers with Fastest Fault Isolation for Redundant Power Supplies MAX8535/MAX8536/MAX8585 ELECTRICAL CHARACTERISTICS (continued) (VCC = 12V (MAX8535/MAX8535A/MAX8585), VCC = 5V (MAX8536), VCS = VCC - 0.1V, RTIMER = 25k, UVP = 2V, OVP = 1V, CGATE = 0.01F, TA = -40C to +85C, unless otherwise noted.) (Note 1) PARAMETER OVERVOLTAGE PROTECTION OVP Fault Threshold OVP Bias Current UNDERVOLTAGE PROTECTION UVP Fault Voltage UVP Bias Current VUVP UVP rising threshold UVP falling threshold 1.200 1.10 1.281 1.19 0.4 V A VOVP OVP rising 1.20 1.281 0.2 V A SYMBOL CONDITIONS MIN TYP MAX UNITS Note 1: Specifications to -40C are guaranteed by design and not production tested. 6 _______________________________________________________________________________________ ORing MOSFET Controllers with Fastest Fault Isolation for Redundant Power Supplies State Diagram MAX8535/MAX8536/MAX8585 CS CS + 0.01V CS - 0.03V CS - 0.4V VCC > VCCOK ALL TRANSITIONS ARE ASYNCHRONOUS VCC VSHARE LATCH IREVERSE BLANKING IFORWARD IREVERSE VSHARE = (CS - VCC) < 0.4V IFORWARD = (VCC - CS) > 0.01V IREVERSE = (CS - VCC) > 0.03V 500ms STANDBY: CPMP: OFF GATE: LOW TIMER >1V WAIT FOR VSHARE CS - VCC > 0.4V CS - VCC < 0.4V UVP FAULT UVP FAULT SHUTDOWN GATE: FAULT NOT LATCHED UVP = OK ON: SET VSHARE LATCH, CHARGE PUMP ON OVP OK AND IREVERSE DURING FIRST 500ms FAULT SHUTDOWN GATE: FAULT LATCHED VCC OR TIMER CYCLED IFORWARD AND OVP FAULT UVP = OK (MAX8585) IREVERSE AFTER 32ms BLANK TIME IREVERSE CONDITION DETECTED AFTER 500ms BLANK TIME (MAX8535/MAX8535A/MAX8536) FAULT SHUTDOWN GATE: NOT LATCHED FAULT SHUTDOWN GATE: FAULT LATCHED VCC OR TIMER CYCLED _______________________________________________________________________________________ 7 ORing MOSFET Controllers with Fastest Fault Isolation for Redundant Power Supplies MAX8535/MAX8536/MAX8585 MAX8535 Typical Operating Characteristics (VCC = 12V, RTIMER = 25k, UVP = 2V, OVP = 1V, CGATE = 0.01F, BUS = 100F, TA = +25C, unless otherwise specified.) GATE-CHARGE CURRENT vs. TIMER RESISTANCE (RTIMER) MAX8535/MAX8536 toc01 SUPPLY CURRENT vs. TEMPERATURE MAX8535/MAX8536 toc02 60 TA = +85C GATE-CHARGE CURRENT (A) 50 TA = +25C 40 TA = -40C 30 20 10 0 10 100 RESISTANCE (k) 3.4 3.2 SUPPLY CURRENT (mA) 3.0 2.8 2.6 2.4 2.2 2.0 TIMER IS UNCONNECTED TIMER = GND 1000 -40 -20 0 20 40 60 80 TEMPERATURE (C) MAX8535 REVERSE-CURRENT THRESHOLD vs. TEMPERATURE REVERSE-CURRENT THRESHOLD (mV) 34 33 32 31 30 29 28 27 26 25 -40 -15 10 35 60 85 TEMPERATURE (C) 20 0 -40 MAX8535/MAX8536 toc03 UVP AND OVP LEAKAGE CURRENT vs. TEMPERATURE MAX8535/MAX8536 toc04 35 140 120 LEAKAGE CURRENT (nA) 100 80 60 40 OVP UVP -20 0 20 40 60 80 TEMPERATURE (C) POWER-UP WAVEFORM (VBUS = 0V) MAX8535/MAX8536 toc05 POWER-UP WAVEFORM (VBUS = 12V) MAX8535/MAX8536 toc06 VCC 10V/div VCC 10V/div IMOSFET 10A/div IMOSFET 2A/div VGATE 20V/div VCS 10V/div 4ms/div 4ms/div VGATE 20V/div VCS 10V/div 8 _______________________________________________________________________________________ ORing MOSFET Controllers with Fastest Fault Isolation for Redundant Power Supplies MAX8535 Typical Operating Characteristics (continued) (VCC = 12V, RTIMER = 25k, UVP = 2V, OVP = 1V, CGATE = 0.01F, BUS = 100F, TA = +25C, unless otherwise specified.) MAX8535/MAX8536/MAX8585 TIMER-ENABLED STARTUP AND SHUTDOWN WAVEFORMS (VCC = 12V, VBUS = 12V) MAX8535/MAX8536 toc07 TIMER-ENABLED STARTUP AND SHUTDOWN WAVEFORMS (VCC = 12V, VBUS = 0V) MAX8535/MAX8536 toc08 VTIMER 2V/div VTIMER 1V/div IMOSFET 50mA/div VGATE 20V/div VCS 10V/div 4ms/div 4ms/div IMOSFET 10A/div VGATE 20V/div VCS 10V/div REVERSE-CURRENT FAULT WAVEFORM (R1 = 10) MAX8535/MAX8536 toc09 UVP FAULT WAVEFORM (R1 = 100) MAX8535/MAX8536 toc10 VCS 1V/div 12V IMOSFET 5A/div 1.25V VUVP 1V/div VFAULT 10V/div VGATE 20V/div VFAULT 10V/div 400ns/div 1s/div VGATE 20V/div VCS 10V/div SELECTIVE OVP SHUTDOWN WAVEFORM (R1 = 10) MAX8535/MAX8536 toc11 VCS 1V/div 12V VGATE1 (OVP UNIT) 20V/div VGATE2 (GOOD UNIT) 20V/div VFAULT 10V/div 1s/div _______________________________________________________________________________________ 9 ORing MOSFET Controllers with Fastest Fault Isolation for Redundant Power Supplies MAX8535/MAX8536/MAX8585 MAX8536 Typical Operating Characteristics (VCC = 12V, RTIMER = 25k, UVP = 2V, OVP = 1V, CGATE = 0.01F, BUS = 100F, TA = +25C, unless otherwise specified.) GATE-CHARGE CURRENT vs. TIMER RESISTANCE (RTIMER) MAX8535/MAX8536 toc12 SUPPLY CURRENT vs. TEMPERATURE MAX8535/MAX8536 toc13 30 25 GATE-CHARGE CURRENT (A) 20 15 10 5 0 10 100 RESISTANCE (k) TA = +25C TA = -40C TA = +85C 2.2 2.0 SUPPLY CURRENT (mA) 1.8 1.6 TIMER = GND 1.4 1.2 1.0 TIMER IS UNCONNECTED 1000 -40 -20 0 20 40 60 80 TEMPERATURE (C) MAX8536 REVERSE-CURRENT THRESHOLD vs. TEMPERATURE MAX8535/MAX8536 toc14 UVP AND OVP LEAKAGE CURRENT vs. TEMPERATURE MAX8535/MAX8536 toc15 35 REVERSE-CURRENT THRESHOLD (mV) 34 33 32 31 30 29 28 27 26 25 -40 -15 10 35 60 140 120 LEAKAGE CURRENT (nA) 100 80 60 40 OVP 20 0 UVP 85 -40 -20 0 20 40 60 80 TEMPERATURE (C) TEMPERATURE (C) POWER-UP WAVEFORM (VBUS = 0V) MAX8535/MAX8536 toc16 POWER-UP WAVEFORM (VBUS = 5V) MAX8535/MAX8536 toc17 VCC 5V/div VCC 5V/div IMOSFET 2A/div IMOSFET 1A/div VGATE 10V/div VCS 5V/div 4ms/div VGATE 10V/div VCS 5V/div 4ms/div 10 ______________________________________________________________________________________ ORing MOSFET Controllers with Fastest Fault Isolation for Redundant Power Supplies MAX8536 Typical Operating Characteristics (continued) (VCC = 12V, RTIMER = 25k, UVP = 2V, OVP = 1V, CGATE = 0.01F, BUS = 100F, TA = +25C, unless otherwise specified.) MAX8535/MAX8536/MAX8585 TIMER-ENABLED STARTUP AND SHUTDOWN WAVEFORMS (VCC = 5V, VBUS = 5V) MAX8535/MAX8536 toc18 TIMER-ENABLED STARTUP AND SHUTDOWN WAVEFORMS (VCC = 5V, VBUS = 0V) MAX8535/MAX8536 toc19 VTIMER 2V/div VTIMER 2V/div IMOSFET 50mA/div VGATE 10V/div VCS 5V/div 4ms/div 10ms/div IMOSFET 1A/div VGATE 10V/div VCS 5V/div REVERSE-CURRENT FAULT WAVEFORM (R1 = 10) MAX8535/MAX8536 toc20 UVP FAULT WAVEFORM (R1 = 100) MAX8535/MAX8536 toc21 VCS 1V/div 5V IMOSFET 5A/div 1.25V VUVP 2V/div VFAULT 5V/div VGATE 10V/div VGATE VFAULT 5V/div 400ns/div 1s/div VCS 1V/div SELECTIVE OVP SHUTDOWN WAVEFORM (R1 = 10) MAX8535/MAX8536 toc22 VCS 1V/div 5V VGATE2 (GOOD UNIT) 10V/div VGATE1 (OVP UNIT) 10V/div VFAULT 5V/div 1s/div ______________________________________________________________________________________ 11 ORing MOSFET Controllers with Fastest Fault Isolation for Redundant Power Supplies MAX8535/MAX8536/MAX8585 Pin Description PIN 1 2 3 4 NAME GATE GND VCC UVP Ground Power-Supply Input. Bypass VCC with a 0.1F capacitor to ground. Undervoltage Input. Connect a resistor-divider from the VCC to GND with the center point connected to UVP. Leave high impedance if not used. UVP fault threshold must be set above VCCOK threshold. Timer Input. Connect a resistor from TIMER to ground to select the charge-pump operating frequency. The charge-pump frequency is proportional to the TIMER output current. TIMER can source up to 100A. If pulled low (<0.5V), the gate drive is disabled. If pulled high (above 1.25V), the charge pump operates at 550kHz. Overvoltage Input. Connect a resistor-divider from the CS to GND with the center point connected to OVP. Connect to GND if not used. Open-Drain Fault Output. FAULT is low during a fault, high impedance during normal operation. Connect a pullup resistor of 50k or higher value to a voltage rail. Current-Sensing Input. Connect CS to the positive side of the system bus. Bypass with 1nF capacitor to GND. FUNCTION Gate Drive Output. Bypass GATE with a 0.01F capacitor to ground. 5 TIMER 6 7 8 OVP FAULT CS Detailed Description Critical loads often employ parallel-connected power supplies with redundancy to enhance system reliability. The MAX8535/MAX8536/MAX8585 are highly integrated but inexpensive MOSFET controllers that provide isolation and redundant power capability in high-reliability systems. The MAX8535/MAX8585 is used in 12V systems and has an internal charge pump to drive the gates of the n-channel pass elements to VCC + 10V. The MAX8536 is used in 3.3V and 5V systems, with a charge pump output of VCC + 5V. During startup, the MAX8535/MAX8536/MAX8585 monitor the voltage drop across external MOSFETs. Once V CC approaches or exceeds the bus voltage, the MOSFETs are turned on. The MAX8535/MAX8536/ MAX8585 feature a dual-purpose TIMER input. A single external resistor from TIMER to ground sets the turn-on speed of the external MOSFETs. Optionally, the TIMER input can be used as a logic-enable pin. Once the device is turned on, the MAX8535/MAX8536/MAX8585 monitor the load, protecting against overvoltage, undervoltage, and reverse-current conditions. Overvoltage and undervoltage fault thresholds are adjustable and can be disabled. The current-limit trip points are set by the external MOSFETs' RDS(ON) , reducing component count. An open-drain logic-low fault output indicates if an overvoltage, undervoltage, or reverse-current fault occurs. VCC V CC is the power-supply input for the MAX8535/ MAX8536/MAX8585 and the input to the internal charge pump that drives the gate of the external MOSFETs. The MAX8535/MAX8536/MAX8585 monitor VCC at all times. VCC connects directly to the power supply (Silver Box or DC-DC power modules). During startup, the device turns on when VCC rises above the undervoltage threshold V CCOK . After V CC exceeds V CCOK and V CC is greater than (CS - 0.4V), the charge pump turns on, driving GATE high and turning on the external MOSFETs. TIMER The MAX8535/MAX8536/MAX8585 provide a programmable-frequency charge pump and shutdown function through TIMER. Slowing down the charge-pump frequency allows a user to program soft-start. Connecting a resistor from TIMER to GND sets the charge-pump frequency from 100kHz to 500kHz. Connecting TIMER to a logic high sets charge-pump operation to a maximum frequency of 550kHz. Pulling TIMER to GND shuts down the charge pump and turns off the external MOSFET. Reducing the charge-pump frequency increases the IREVERSE startup blank time (see the Reverse-Current Fault section). GATE GATE is the output of the internal charge pump that drives the external MOSFETS. During startup, the GATE voltage ramps up according to the charge-pump frequency. At 250kHz, the GATE drive current for the MAX8535/MAX8585 is 25A and the GATE drive current 12 ______________________________________________________________________________________ ORing MOSFET Controllers with Fastest Fault Isolation for Redundant Power Supplies for the MAX8536 is 12A. Increasing the charge-pump frequency increases the GATE drive current. Adding a resistor from GATE to the gate of the external MOSFETs further increases turn-on and turn-off times. effect. In this way, only the input supply, which is causing the overvoltage condition, is turned off in a redundant power system application. An overvoltage fault is a latching fault condition, and requires VCC or TIMER to be cycled to reset the part. Reverse-Current Fault The MAX8535/MAX8536 contain a reverse-current protection feature. If, after the 500ms (typ) startup blank time, an IREVERSE condition is detected, the MAX8535/ MAX8536 turn off the external MOSFET and a fault is latched. A reverse-current fault forces the MAX8535/ MAX8536 to latch off. Cycle V CC or TIMER to exit a latched fault condition. Startup blanking time allows the incoming power supply to connect to the system bus at V BUS - 0.4V. Reducing charge-pump frequency increases the startup blanking time. The MAX8585 does not latch this fault. MAX8535/MAX8536/MAX8585 CS The voltage drop across the external MOSFETs is measured between the VCC and CS inputs. CS connects to the positive side of the system bus. The voltage drop across the CS and VCC determines operation modes. IFORWARD is defined as VCC - CS > 0.01V. IREVERSE is defined as CS - V CC > 0.03V in all except the MAX8585. In the MAX8585, IREVERSE = 0V. FAULT Conditions The MAX8535/MAX8536/MAX8585 contain a versatile FAULT output that signals overvoltage, undervoltage, or reverse-current conditions. During a FAULT condition, the charge pump shuts down and the GATE discharges to ground. Undervoltage Fault The MAX8535/MAX8536/MAX8585 turn off the external MOSFET if the input voltage falls below the UVP threshold. If UVP is left unconnected, the undervoltage input is disabled. Set the undervoltage threshold to any value above VCCOK. When the input voltage rises above the UVP threshold, FAULT clears and the MOSFET turns back on. Overvoltage Fault The MAX8535/MAX8536/MAX8585 contain an adjustable OVP feature. A resistor-divider from the CS system bus to the OVP input pin sets the overvoltage threshold. When the OVP level is exceeded and the part is in the IFORWARD condition (defined as VCC > CS + 0.01V), the MAX8535/MAX8536/MAX8585 turn off the external MOSFET and a fault is latched. If there is no I FORWARD condition, an OVP detection has no Applications Information Selecting the Timer Resistor To set the frequency of the internal charge-pump operation, connect a resistor from TIMER to GND. Determine the frequency by using the equation: 1.25V Frequency = 5 x 100A kHz / A RTIMER Pull TIMER above 1.5V for maximum charge-pump frequency. Pull TIMER below 0.5V to disable the charge pump. Leave TIMER unconnected for a 500kHz charge-pump frequency. Selecting the Gate Capacitor and Gate Resistor The charge pump uses an internal monolithic transfer capacitor to charge the external MOSFET gates. Table 1. MAX8535/MAX8536/MAX8585 Fault Modes FAULT MODE VCC UVLO UVP pin undervoltage protection OVP pin overvoltage protection Reverse-current protection (MAX8535/MAX8536) Reverse-current protection (MAX8585) VCC internal (MAX8535/MAX8585) overvoltage protection PIN CONDITIONS VCC < VCCOK UVP < 1.25V OVP > 1.25V VCC > CS + 0.01V VCC < CS - 0.03V Gate ON for t > 0.5s VCC < CS Gate ON for t > 0.032s VCC > 14.5V GATE PIN Low Low Low Low Low Low FAULT PIN High impedance Low Low Low Low Low LATCHING No No Yes Yes No No ______________________________________________________________________________________ 13 ORing MOSFET Controllers with Fastest Fault Isolation for Redundant Power Supplies MAX8535/MAX8536/MAX8585 Normally, the external MOSFET's gate capacitance is sufficient to serve as a reservoir capacitor. If the MOSFETs are located at a significant distance from the MAX8535/MAX8536/MAX8585, place a local bypass capacitor (0.01F, typ) across GATE and GND. For slower turn-on times, add a small capacitor between GATE and GND and a series resistor between GATE and the gate of the MOSFETs. MOSFETs at all times. The MAX8535/MAX8536/ MAX8585 determine the state of the monitored power supply by measuring the voltage drop across the external MOSFETs. With two external MOSFETs, the equation becomes: VDSTOTAL = RDS(ON)1 x ILOAD + RDS(ON)2 x ILOAD Selecting a MOSFET with a low RDS(ON) allows more current to flow through the MOSFETs before the MAX8535/MAX8536/MAX8585 detect reverse-current (IREVERSE) and forward-current (IFORWARD) conditions. Set the UVP Fault Threshold To set the undervoltage lockout threshold, use a resistordivider connected between VCC and GND, with the center node of the divider connected to UVP. For example, use a 10k resistor (R4 in Figure 4) from UVP to GND and calculate the other resistor (R3) using: V R3 = R4 UVLO - 1 VUVP where VUVLO is the desired undervoltage lockout voltage and VUVP is the UVP reference threshold specified in the Electrical Characteristics (1.25V, typ). To defeat the UVP, leave UVP unconnected. Using a Single MOSFET Single MOSFETs can be used if the OVP function is not needed. Connect the source of the MOSFET to V CC and the drain of the MOSFET to CS. Layout Guidelines Keep all traces as short as possible and maximize the high-current trace width to reduce the effect of undesirable parasitic inductance. The MOSFET generates a fair amount of heat because of the high currents involved. In order to dissipate the heat generated by the MOSFET, make the power traces very wide with a large amount of copper area, and place the MAX8535/ MAX8536/MAX8585 as close as possible to the drain of the external MOSFET. A more efficient way to achieve good power dissipation on a surface-mount package is to lay out two copper pads directly under the MOSFET package on both sides of the board. Connect the two pads to the ground plane through vias and use enlarged copper mounting pads on the topside of the board. Use a ground plane to minimize impedance and inductance. Refer to the MAX8535 Evaluation Kit data sheet for an example of a PC board layout. In addition to the usual high-power considerations, bypassing prevent false faults by: 1) Bypass VCC with a 0.1F capacitor to ground and bypassing CS with a 1nF capacitor to ground. 2) Making the traces connecting UVP and OVP as short as possible. 3) Kelvin connecting V CC and CS to the external MOSFET. Set the OVP Fault Threshold To set the OVP threshold, use a resistor-divider connected between CS and GND, with the center node of the divider connected to OVP. For example, use a 10k resistor (R6 in Figure 4) from OVP to GND and calculate the other resistor, R5, using: V R5 = R6 OVLO - 1 VOVP where VOVLO is the desired overvoltage lockout voltage and VOVP is the OVP reference threshold specified in the Electrical Characteristics (1.25V, typ). To defeat the OVP, connect the OVP input to GND. MOSFET Selection The MAX8535/MAX8536/MAX8585 drive n-channel MOSFETs. The most important feature of the MOSFETs is RDS(ON). As load current flows through the external MOSFET, a voltage (VDS) is generated from drain-tosource due to the MOSFET's on-resistance, RDS(ON). The MAX8535/MAX8536/MAX8585 monitor VDS of the 14 ______________________________________________________________________________________ ORing MOSFET Controllers with Fastest Fault Isolation for Redundant Power Supplies Functional Diagrams GATE VCC CS MAX8535/MAX8536/MAX8585 VCC CHARGE PUMP 400mV 30mV* 10mV *0mV OFFSET IN THE MAX8585 CLK SHUTDOWN VOLTAGE SHARE REVERSE CURRENT FORWARD CURRENT 14.5V OVP VCC FAULT CONTROL LOGIC OVERVOLTAGE INTERNAL OVERVOLTAGE EXTERNAL UNDERVOLTAGE 1.25V IOSC TIMER ENABLE UVP 1.25V REF MAX8535 MAX8585 GND 1.25V Figure 1. MAX8535/MAX8585 Functional Diagram GATE VCC CS VCC CHARGE PUMP 400mV 30mV 10mV CLK SHUTDOWN VOLTAGE SHARE REVERSE CURRENT FORWARD CURRENT VCC FAULT CONTROL LOGIC OVP OVERVOLTAGE EXTERNAL UNDERVOLTAGE 1.25V IOSC TIMER ENABLE UVP 1.25V REF MAX8536 1.25V GND Figure 2. MAX8536 Functional Diagram ______________________________________________________________________________________ 15 ORing MOSFET Controllers with Fastest Fault Isolation for Redundant Power Supplies MAX8535/MAX8536/MAX8585 Typical Application Circuits Q1 AND Q2 2XSUB75N03-04 30V/4m OUT+ +VO -VO OUTPUT: 12V/20A R1 10 R3 SILVER BOX 53.6k OR RECTIFIERS C1 0.01F, 50V GATE VCC C2 0.1F, 16V UVP TIMER CS FAULT C3 1nF MAX8535 MAX8585 OVP GND R6 10k R4 10k OUT- R7 24.9k ENABLE Figure 3. Typical Application Circuit for 12V/20A Output with OVP and UVP Q1 AND Q2 2XSUB75N03-04 30V/4m OUT+ +VO -VO OUTPUT: 3.3V OR 5V/20A R1 10 R3 SILVER BOX 13.3k OR RECTIFIERS C1 0.01F, 50V GATE VCC C2 0.1F, 16V UVP TIMER R4 10k OUTGND CS FAULT C3 1nF MAX8536 OVP R7 24.9k R6 10k Figure 4. Typical Application Circuit for 3.3V or 5V/20A Output with OVP and UVP 16 ______________________________________________________________________________________ OUTPUT BUS R5 35.7k R2 51k OUTPUT BUS R5 100k R2 51k ORing MOSFET Controllers with Fastest Fault Isolation for Redundant Power Supplies MAX8535/MAX8536/MAX8585 Q1 SUB75N03-04 30V/4m OUTPUT: 12V/20A OUT+ +VO -VO R1 10 SILVER BOX OR RECTIFIERS C3 1nF OUTPUT BUS R2 51k C1 0.01F, 50V ON C2 0.1F, 16V OFF ENABLE R4 7.5k GATE VCC CS FAULT MAX8535 MAX8585 TIMER R3 7.5k GND UVP OVP N.C. OUT- Figure 5. Typical Application Circuit for 12V/20A Output without OVP and UVP ______________________________________________________________________________________ 17 ORing MOSFET Controllers with Fastest Fault Isolation for Redundant Power Supplies MAX8535/MAX8536/MAX8585 V+ Q1A AND Q2A 2XSUB75N03-04 30V/4m VCCA = 12V/20A OUT+ +VO -VO R1A 10 R3A SILVER BOX 53.6k A C1A 0.01F, 50V GATE VCC C2A 0.1F, 16V UVP TIMER U1 CS FAULT C3A 1nF MAX8535 MAX8585 GND OVP R4A 10k OUT- R7A 24.9k R6A 10k Q1B AND Q2B 2XSUB75N03-04 30V/4m VCCB = 12V/20A OUT+ R1B 10 R3B SILVER BOX 53.6k B C1B 0.01F, 50V GATE VCC C2B 0.1F, 16V UVP TIMER U2 CS FAULT C3B 1nF MAX8535 MAX8585 GND OVP R4B 10k OUT- R7B 24.9k N+1 Figure 6. N + 1 Redundant Power System Connections 18 ______________________________________________________________________________________ OUTPUT BUS R2B 51k OUTPUT BUS R5A 100k R2A 51k ORing MOSFET Controllers with Fastest Fault Isolation for Redundant Power Supplies Pin Configuration TOP VIEW GATE GND VCC UVP 1 2 3 4 8 CS FAULT OVP TIMER MAX8535/MAX8536/MAX8585 Chip Information TRANSISTOR COUNT: 3011 PROCESS: BiCMOS MAX8535 MAX8536 MAX8585 MAX 7 6 5 ______________________________________________________________________________________ 19 ORing MOSFET Controllers with Fastest Fault Isolation for Redundant Power Supplies MAX8535/MAX8536/MAX8585 Package Information (The package drawing(s) in this data sheet may not reflect the most current specifications. For the latest package outline information, go to www.maxim-ic.com/packages.) 8LUMAXD.EPS 8 4X S 8 INCHES DIM A A1 A2 b c D e E H MIN 0.002 0.030 MAX 0.043 0.006 0.037 MILLIMETERS MAX MIN 0.05 0.75 1.10 0.15 0.95 y 0.500.1 0.60.1 E H 1 0.60.1 1 D L S BOTTOM VIEW 0.014 0.010 0.007 0.005 0.120 0.116 0.0256 BSC 0.120 0.116 0.198 0.188 0.026 0.016 6 0 0.0207 BSC 0.25 0.36 0.13 0.18 2.95 3.05 0.65 BSC 2.95 3.05 4.78 5.03 0.41 0.66 0 6 0.5250 BSC TOP VIEW A2 A1 A e c b L SIDE VIEW FRONT VIEW PROPRIETARY INFORMATION TITLE: PACKAGE OUTLINE, 8L uMAX/uSOP APPROVAL DOCUMENT CONTROL NO. REV. 21-0036 J 1 1 Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied. Maxim reserves the right to change the circuitry and specifications without notice at any time. 20 ____________________Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600 (c) 2004 Maxim Integrated Products Printed USA is a registered trademark of Maxim Integrated Products. |
Price & Availability of MAX8585EUA
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |