Tripp Lite. All Rights Rese...
|
Part No. |
SUINT1500RTXL2UA
|
OCR Text |
...ave ac output at selectable 200/208/220/230/240v ac (+/-2%). removes harmonic distortion, fast electrical impulses, frequency fluctuations a...230v; 240v nominal voltage details 230v default frequency compatibility 50 / 60 hz frequency compati... |
Description |
SmartOnline 200-240V 1.5kVA 1.2kW On-Line Double-Conversion UPS, Extended Run, SNMP,Webcard, 2U Rack/Tower, USB, DB9 Serial
|
File Size |
486.64K /
5 Page |
View
it Online |
Download Datasheet
|
|
|
 |
Tripp Lite. All Rights Rese...
|
Part No. |
SUINT2200RTXL2UA
|
OCR Text |
... packs. full-time sine wave 200/208/220/230 or 240v +/-3% output. online, double-conversion uninterruptible power supply (ups) actively conv...230v; 240v nominal voltage details 230v default frequency compatibility 50 / 60 hz 2 / 6
freque... |
Description |
SmartOnline 200-240V 2.2kVA 1.6kW On-Line Double-Conversion UPS, Extended Run, SNMP,Webcard, 2U Rack/Tower, USB, DB9 Serial
|
File Size |
488.97K /
6 Page |
View
it Online |
Download Datasheet
|
|
|
 |
Tripp Lite. All Rights Rese...
|
Part No. |
SUINT3000RTXL2U
|
OCR Text |
... packs. full time sine wave 200/208/220/230/240v output with +/-2% voltage regulation. uninterruptible power supply (ups) actively converts ...230v; 240v nominal voltage details 230v default frequency compatibility 50 / 60 hz frequency compati... |
Description |
SmartOnline 200-240V 3kVA 2.5kW On-Line Double-Conversion UPS, Extended Run, SNMP,Webcard, 2U Rack/Tower, USB, DB9 Serial
|
File Size |
490.27K /
6 Page |
View
it Online |
Download Datasheet
|
|
|
 |
Tripp Lite. All Rights ...
|
Part No. |
SU10000RT3UG
|
OCR Text |
...put within 2% of selectable 200/208/220/230/240v nominal during brownouts as low 100v and overvoltages as high as 300v supports 50/60hz oper...230v; 240v 2 / 6
nominal voltage details voltage selection via front panel lcd interface freque... |
Description |
SmartOnline 200-240V 10kVA 9kW On-Line Double-Conversion UPS, Extended Run, SNMP,Webcard, 6U Rack-Tower, C19 Outlets
|
File Size |
534.38K /
6 Page |
View
it Online |
Download Datasheet
|
|
|
 |
Tripp Lite. All Rights ...
|
Part No. |
SU5000RT3UHV
|
OCR Text |
...put within 2% of selectable 200/208/220/230/240v ac. corrects brownouts to 156v and overvoltages to 276v. frequency regulation locks output ...230v ac; 240v ac ups input connection type l6-30p ups input cord length (ft.) 10 ups input cord leng... |
Description |
SmartOnline 200-240V 5kVA 3.5kW On-Line Double-Conversion UPS, Extended Run, SNMP,Webcard, 5U Rack/Tower, DB9 Serial
|
File Size |
517.24K /
5 Page |
View
it Online |
Download Datasheet
|
|
|
 |
Tripp Lite. All Rights ...
|
Part No. |
SU6000RT3UHV-15
|
OCR Text |
...put within 2% of selectable 200/208/220/230/240v ac output 20 minutes runtime at half load (2100w) / 8 minutes at full load (4200w) with inc...230v; 240v nominal voltage details voltage selection via front panel lcd interface frequency compati... |
Description |
SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP,Webcard, 6U Rack/Tower, DB9 Serial, Hardwire
|
File Size |
522.35K /
6 Page |
View
it Online |
Download Datasheet
|
|
|
 |
Tripp Lite. All Rights ...
|
Part No. |
SU6000RT3UHVXL
|
OCR Text |
...put within 2% of selectable 200/208/220/230/240v ac output 30 minutes runtime at half load (2100w) / 12 minutes at full load (4200w) with in...230v; 240v nominal voltage details voltage selection via front panel lcd interface frequency compati... |
Description |
SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP,Webcard, 6U Rack/Tower, DB9 Serial, Hardwire
|
File Size |
517.94K /
5 Page |
View
it Online |
Download Datasheet
|
|
|
 |
List of Unclassifed Man...
|
Part No. |
SU6000RT3UHV
|
OCR Text |
...put within 2% of selectable 200/208/220/230/240v ac output 20 minutes runtime at half load (2100w) / 8 minutes at full load (4200w) with inc...230v; 240v nominal voltage details voltage selection via front panel lcd interface frequency compati... |
Description |
SmartOnline 6kVA On-Line Double-Conversion UPS, 6U Rack/Tower, 200-240V Hardwire output
|
File Size |
527.50K /
7 Page |
View
it Online |
Download Datasheet
|
For
208 230v Found Datasheets File :: 78 Search Time::2.719ms Page :: | 1 | 2 | 3 | 4 | 5 | <6> | 7 | 8 | |